The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING UNVERIFIED DETECTORS | 4941 W WEST END AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | COLUMNS ARE SCABBED / TWISTED / OUT OF PLUMB. RAILINGS ARE ONLY 30" AND PULLING STRINGERS INADEQUATELY SUPPORTED AT COLUMNS LEDGERS RAILED TO BUILDING EXTERIOR WALLS. JOIST HANGERS TREADS ARE LOOSE / WORN OUT. BEAMS ARE ONLY NAILED TO COLUMNS. OBTAIN PLANS AND PERMITS TO REPAIR / REPLACE REAR PORCH. | 4941 W WEST END AVE | PERIODIC | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | REARGATE/CHAINED& PADLOCKED | 4941 W WEST END AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | BUILDING & REAR PORCH/ NO ENTRY | 4941 W WEST END AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | COLUMNS ARE SCABBED / TWISTED / OUT OF PLUMB. RAILINGS ARE ONLY 30" AND PULLING STRINGERS INADEQUATELY SUPPORTED AT COLUMNS LEDGERS RAILED TO BUILDING EXTERIOR WALLS. JOIST HANGERS TREADS ARE LOOSE / WORN OUT. BEAMS ARE ONLY NAILED TO COLUMNS. OBTAIN PLANS AND PERMITS TO REPAIR / REPLACE REAR PORCH. | 4941 W WEST END AVE | PERIODIC | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | REARGATE/CHAINED& PADLOCKED | 4941 W WEST END AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | FRONT ENTRYWAY WALLS - WASHED OUT MORTAR. | 4941 W WEST END AVE | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING - OWNER'S ID SIGN NOT POSTED. | 4941 W WEST END AVE | PERIODIC | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | SOUTH ELEVATION 3RD FLOOR - BROKEN WINDOW PANES OTHER BOARDED UP. | 4941 W WEST END AVE | PERIODIC | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | 4941 AND 4943 W./ BASEMRENT CEILING - DRYWALL HAS HOLES. | 4941 W WEST END AVE | PERIODIC | FAILED | View |
CARB MONOX DETECT IN RESID | 4943 W./ BASEMENT - MISSING CARBON MONOXIDE DETECTOR. | 4941 W WEST END AVE | PERIODIC | FAILED | View |
PARAPET | WEST PARAPET WALL - WASHED OUT MORTAR AND SPALLING BRICKS. | 4941 W WEST END AVE | PERIODIC | FAILED | View |
REPAIR COPING | EAST ( REAR ) COPING TILE - BROKEN. | 4941 W WEST END AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR STAIR | SOUTH EXTERIOR STAIRS GRADE TO BASEMENT AND AREWAY WALLS - MISSING GUARDRAILS. | 4941 W WEST END AVE | PERIODIC | FAILED | View |
CONNECT DOWNSPOUT TO SEWER | SOUTH DOWNSPOUT - NOT CONNECTED TO SEWER. | 4941 W WEST END AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | SOUTH THREE STORY PORCH, EAST GUARD RAILING SECTIONS ( ALL LEVELS ) ARE LOOSE, CREATING A DANGEROUS CONDITION.GUARD AND STAIR RAILING SECTIONS FASTENED TO EXTERIOR WALLS WITH WOOD SCREWS ONLY. GUARD AND STAIR RAILINGS SECTIONS FASTENED TO 4"X4" RAILINGS POSTS AND COLUMNS WITH NAILS AND WOOD SCREWS ONLY.GUARD RAILINGS SECTIONS OVER 4'-0" LONG - BOTTOM LOOSE AND PULLING.STRINGERS FASTENED TO HEADERS, 4"X4" RAILING POSTS AND COLUMNS WITH WOOD SCREWS AND NAILS ONLY.PERMIT ONLY REQUIRED FOR REPAIRS. | 4941 W WEST END AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING UNVERIFIED DETECTORS | 4941 W WEST END AVE | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | BUILDING NOT REGISTERED YEARS 2011 AND 2012. | 4941 W WEST END AVE | PERIODIC | FAILED | View |