Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR PORCH SYSTEM | REAR PORCHES (2) PARTIALLY ENCLOSED-ROTTED COLUMNS ARE SEPERATING AT THE BEAM CONNECTIONS; GAPS. 6X6 BEAMS ARE NOT CENTERED ON THE COLUMN CONNECTIONS. UNDERSIZED 2X6 DECK JOISTS FOR A 13 FEET 9 INCH SPAN. EDGE BEAMS ARE ONLY NAILED AT THE COLUMN CONNECTIONS. STRINGERS ARE ONLY NAILED INTO THE COLUMN/NEWELL POST/HEADER BEAM CONNECTIONS; WEST STRINGER FROM (GRADE) TO (1) OF NORTH PORCH IS FRACTURED. WORN TREADS. GUARDRAILS SHIFT UPON LOAD; ARE ONLY 32 INCHES IN HEIGHT. RAILS WITH BROKEN LOOSE AND MISSING PICKETS. MOST MEMBERS WITH NAILS PROTRUDING OUT. MOST MEMBERS ARE ONLY TOE NAILED AT THE CONNECTIONS. PLANS AND PERMIT REQUIRED FOR REPAIRS. | 8116 S EVANS AVE | COMPLAINT | FAILED | View |
REPAIR/REBUILD GARAGE OR SHED | GARAGE-BROKEN OVERHEAD DOOR; REMAINS IN THE OPEN POSITION. SERVICE DOOR IS OUT OF PLUMB; DOES NOT CLOSE. | 8116 S EVANS AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO RESPONSE-UNVERIFIED DETECTORS. | 8116 S EVANS AVE | COMPLAINT | FAILED | View |
FILE BLDG REGISTRATION | BUILDING-NOT REGISTERED FROM: 2005 THRU 2010. | 8116 S EVANS AVE | COMPLAINT | FAILED | View |
EXPOSED WIRING | CEILING LIGHT-EXPOSED WIRING. | 8116 S EVANS AVE | COMPLAINT | FAILED | View |
INT WALL/CEILING CHIP PLASTER | 8118 1ST ALL AREA CEILING BUCKLING AND CRACKED PLASTER | 8116 S EVANS AVE | COMPLAINT | FAILED | View |
CARPETING | 8118 1ST CARPET UNSANITARY | 8116 S EVANS AVE | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | 8118 PORCH NO FOOTING PICKETS BOWED AND LOOSE LOOKOUT ROTTED AND PULLING AWAY FROM FIRE CUT UPRIGHT ROTTED AND SPLIT STRINGER SCAB WORK NO JOIST HANGER RAILS LOOSE IMPROPER SUPPORT FOR STRINGER 8116 LOOKOUTS 6X6 UPRIGHTS ROTTED WOOD SPLIT RAILS LOOSE PICKETS BOWED AND LOOSE IMPROPER SUPPORT FOR STRINGERS 4X4 AND 6X6 TWISTED 6X6 UPRIGHTS IMPROPER CONNECTION SUBMIT PLANS AND PERMITS FOR REPAIRS | 8116 S EVANS AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | POST OWNERSHIP | 8116 S EVANS AVE | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | SERVICE WALK BROKEN CONCRETE | 8116 S EVANS AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | BASEMENT WINDOW BOARDED UP | 8116 S EVANS AVE | COMPLAINT | FAILED | View |
SCREEN OUTER DOORS, WINDOWS | WINDOW SCREENS MISSING | 8116 S EVANS AVE | COMPLAINT | FAILED | View |
REPAIR/REBUILD GARAGE OR SHED | GARAGE WEST CHIMNEY LOOSE BRICKS ENTRANCE DOOR AND FRAME ROTTED | 8116 S EVANS AVE | COMPLAINT | FAILED | View |
REPAIR SCREENS | WINDOW SCREENS TORN | 8116 S EVANS AVE | COMPLAINT | FAILED | View |
NO KEY TO USE EXIT DOOR | IRON GATES KEYLOCKS | 8116 S EVANS AVE | COMPLAINT | FAILED | View |
FILE BLDG REGISTRATION | REGISTER BUILDING 2005 2006 | 8116 S EVANS AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | OWNER'S I.D. SIGN-NOT POSTED. | 8116 S EVANS AVE | COMPLAINT | FAILED | View |