The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
NO PERMIT WIRING | INSTALLATION OF NEW METER CABINET WITHOUT PROPER PERMIT | 5744 S GREEN ST | COMPLAINT | FAILED | View |
INSTALL COVERS | REPLACE MISSING METER COVERS DANGEROUS AND HAZARDOUS LIVE WIRE EXPOSED TO MOISTURE AND PUBLIC | 5744 S GREEN ST | COMPLAINT | FAILED | View |
SEE INSPECTOR COMMENTS | PROVIDE REQUIRED SUPPLEMENTAL GROUND AT METER 18-27-250.50 & 30 | 5744 S GREEN ST | COMPLAINT | FAILED | View |
SEE INSPECTOR COMMENTS | REPLACE ROTTED CORRODED SERVICE ENTRANCE CABLE FROM METER TO PANELS DANGEROUS AND HAZARDOUS 18-27-110.7 A PERMIT IS REQUIRED TO CORRECT VIOLATIONS | 5744 S GREEN ST | COMPLAINT | FAILED | View |
SEPARATION OF DWELLING ADEQUAT | BASEMENT CEILING FURNACE AREA WOOD LATH | 5744 S GREEN ST | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | WINDOW BURGLARS | 5744 S GREEN ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | EXTERIOR WALLS MORTAR MISSING | 5744 S GREEN ST | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | REAR PORCH UPRIGHTS 4X4 POST RAILS PICKETS TREADS RISER DECKING DECK JOIST STRINGER ROTTED DECKING SLOPE TO MUCH NO FOOTING RAILS LOOSE LOOKOUTS NOT SEAL IN WALL PROPERLY SUBMIT PLANS AND PERMITS FOR REPAIRS DANGEROUS AND HAZARDOUS | 5744 S GREEN ST | COMPLAINT | FAILED | View |
REPAIR AREAWAY WALL | BASEMENT STAIR RETAINING WALL BUCKLING AND MORTAR MISSING | 5744 S GREEN ST | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | BUILDING YARD AREA JUNK AND DEBRIS | 5744 S GREEN ST | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | SERVICE WALK BROKEN CONCRETE | 5744 S GREEN ST | COMPLAINT | FAILED | View |
REPAIR COPING | COPING TILES LOOSE AND BROKEN | 5744 S GREEN ST | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | POST OWNERSHIP | 5744 S GREEN ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | FRONT PORCH WING WALL RISER OPEN JOINTS LIME STONE CAP AND LANDING BROKEN CONCRETE | 5744 S GREEN ST | COMPLAINT | FAILED | View |
CHIMNEY | CHIMNEY FRACTURE AND LEANING SOUTH ELEVATION | 5744 S GREEN ST | COMPLAINT | FAILED | View |
CUT OR REMOVE HIGH WEEDS | YARD FENCE WEEDS AND OVER GROWN TREES | 5744 S GREEN ST | COMPLAINT | FAILED | View |
REPAIR FENCE | REAR FENCE BENT AND LOOSE | 5744 S GREEN ST | COMPLAINT | FAILED | View |
REPAIR DOOR, INT. | BASEMENT APARTMENT DOOR FRAME BROKEN | 5744 S GREEN ST | COMPLAINT | FAILED | View |
BASEMENT, DISCONTINUE | BASEMENT ALTER | 5744 S GREEN ST | COMPLAINT | FAILED | View |
STAIRWELL ENCLOSURE - BASEMENT | BASEMENT STAIRWELL OPEN | 5744 S GREEN ST | COMPLAINT | FAILED | View |
PARTITIONS, N/L/B - BASEMENT | BASEMENT PARTITION WALL FURNACE AREA EXPOSE STUDS | 5744 S GREEN ST | COMPLAINT | FAILED | View |
CEILING HEIGHT - 7' - BASEMENT | BASEMENT CEILING HEIGHT 6'2 | 5744 S GREEN ST | COMPLAINT | FAILED | View |
INT WALL/CEILING PEELING PAINT | BASEMENT GLASS BLOCK WINDOW | 5744 S GREEN ST | COMPLAINT | FAILED | View |
PAINT SHUT | BASEMENT GLASS BLOCK WINDOW | 5744 S GREEN ST | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | BASEMENT DECONVERT | 5744 S GREEN ST | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | BASEMENT REMOVE PARTITION | 5744 S GREEN ST | COMPLAINT | FAILED | View |
RMV PLBFIX INSTALLD W/0 PERMIT | BASEMENT REMOVE PLUMBING AND CAP BEHIND WALL | 5744 S GREEN ST | COMPLAINT | FAILED | View |
REMOVE GAS LINE AND JET | BASEMENT REMOVE GASLING AND CAP BEHIND WALL | 5744 S GREEN ST | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | JOIST AND BEAMS UNDERSIZED AND ROTTED. GUARDRAILS WITH EXCESSIVE GAPS, LOOSE RAILS AND PICKETS. BEAM TO COLUMN CONNECTION ROTTED. MISSING ALL NECESSARY HARDWARE SUCH AS BOLTS, BRACKETS, JOIST HANGERS AND TIE STRAPS. STRINGERS ROTTED, CRACKED AND PULLING OUT OF POSITION. COLUMNS OVERNOTCHED, STACKED, AND ROTTED OBTAIN PLANS AND PERMITS TO REPLACE DANGEROUS AND HAZARDOUS PORCH SYSTEM | 5744 S GREEN ST | COMPLAINT | FAILED | View |
PARAPET | ERODED MORTAR, SPALLED MASONRY, LOOSE, MISSING, BRICKS AT NORTH AND SOUTH ELEVATIONS. OPEN JOINTS LOOSE LIMESTONE UNITS AT EAST ELEVATION. | 5744 S GREEN ST | COMPLAINT | FAILED | View |
REPAIR COPING | COPING TILES LOOSE AT NORTH AND SOUTH ELEVATION. | 5744 S GREEN ST | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | NUMEROUS ABANDONED AUTOS IN REAR YARD. | 5744 S GREEN ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | FRONT LIMESTONE PORCH SYSTEM - LOOSE LIMESTONE UNITS. COLUMNS SHIFTING. OPEN JOINTS AT STAIRS LOOSE WINGWALLS. | 5744 S GREEN ST | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | POST MANAGEMENT INFO IN CONSPICUOUS PLACE. | 5744 S GREEN ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO INTERIOR. | 5744 S GREEN ST | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | WEST BASEMENT DOOR BROKEN DON'T CLOSE | 5744 S GREEN ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH - LOOSE, ROTTED, DETACHED STAIR TREADS AND BANISTERS. CENTER BEAM - COLUMN JOINTS IS PULLING APART. THE WOOD IS ROTTED AT THIS CRITICAL STRUCTURAL CONNECTION. PERMIT REQUIRED FOR REPAIRS | 5744 S GREEN ST | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | REAR JUNK, DEBRIS. | 5744 S GREEN ST | COMPLAINT | FAILED | View |
WATCHMAN | 5744 S GREEN ST | COMPLAINT | CLOSED | View | |
POST OWNER NAME OF VACNT BLDG | 5744 S GREEN ST | COMPLAINT | CLOSED | View | |
SUBMIT FOR APPROVAL PLANS | 5744 S GREEN ST | COMPLAINT | CLOSED | View | |
FILE BLDG REGISTRATION | 5744 S GREEN ST | COMPLAINT | CLOSED | View | |
MAINTAN BLDG IN SAFE CONDITION | 5744 S GREEN ST | COMPLAINT | CLOSED | View | |
REPAIR PORCH SYSTEM | 2 STORY WOOD PORCH: NO VISIBLE FOOTING ON NORTH COLUMN.; UNDERSIZED 2"X6" DECK JOISTS SPAN 11'-7".; UNDERSIZED 2"X8" RIM JOIST SPAN 10'-6".; SOUTH COLUMN IS BUCKLING OUT, COLUMN SECTIONS ARE ERECTED ON ON TOP OF OTHER AND FASTENED WITH NAILS ONLY.; SOUTH BEAM IS FASTENED TO COLUMN WITH LIGHT GAGE TIE STRAP.; GUARDRAILS ARE ONLY 32" HIGH.; RAILINGS, STRINGERS AND RIM JOIST ARE FASTENED WITH NAILS ONLY.; STAIRS AND LANDING HAVE EXCESSIVE PITCH.; TREADS ARE ONLY 9-1/2" DEEP. PLANS AND PERMIT ARE REQUIRED FOR PORCH REPAIRS. | 5744 S GREEN ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | 2 STORY WOOD PORCH: NO VISIBLE FOOTING ON NORTH COLUMN.; UNDERSIZED 2"X6" DECK JOISTS SPAN 11'-7".; UNDERSIZED 2"X8" RIM JOIST SPAN 10'-6".; SOUTH COLUMN IS BUCKLING OUT, COLUMN SECTIONS ARE ERECTED ON ON TOP OF OTHER AND FASTENED WITH NAILS ONLY.; SOUTH BEAM IS FASTENED TO COLUMN WITH LIGHT GAGE TIE STRAP.; GUARDRAILS ARE ONLY 32" HIGH.; RAILINGS, STRINGERS AND RIM JOIST ARE FASTENED WITH NAILS ONLY.; STAIRS AND LANDING HAVE EXCESSIVE PITCH.; TREADS ARE ONLY 9-1/2" DEEP. PLANS AND PERMIT ARE REQUIRED FOR PORCH REPAIRS. | 5744 S GREEN ST | COMPLAINT | CLOSED | View |
DEBRIS, EXCESSIVE | REAR YARD - CONSTRUCTION DEBRI. | 5744 S GREEN ST | COMPLAINT | FAILED | View |
CUT OR REMOVE HIGH WEEDS | REAR YARD - HIGH WEEDS. | 5744 S GREEN ST | COMPLAINT | FAILED | View |
SCREEN OUTER DOORS, WINDOWS | SOUTH AND EAST ELEVATIONS - MISSING WINDOW SCREENS. | 5744 S GREEN ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING - NO RESPONSE, UNABLE TO VERIFY DETECTORS. | 5744 S GREEN ST | COMPLAINT | FAILED | View |
PARAPET | PARAPET WALLS MORTAR MISSING | 5744 S GREEN ST | COMPLAINT | FAILED | View |
REPAIR/WRECK DANGER RESID PREM | 5744 S GREEN ST | COMPLAINT | CLOSED | View | |
REPAIR ROOF | SECOND FLOOR APARTMENT -(1) KITCHEN AND REAR BEDROOM - WATER DAMAGED CEILING AND WALLS FROM ROOF LEAKS(2) HALL ADJACENT TO BATHROOM - WATER INSIDE OF LIGHT FIXTURE GLOBE FROM ROOF LEAKS(3) REAR EXTERIOR WALL - ROTTED WOOD BEHIND THE GUTTER - RAPIDLY LEAKING WHEN RAINING | 5744 S GREEN ST | COMPLAINT | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | SECOND FLOOR APARTMENT AT KITCHEN AND REAR BEDROOM - WATER DAMAGED CEILING AND WALLS WITH DISCOLORED AND BUBBLED PAINT | 5744 S GREEN ST | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | INTERIOR FRONT STAIRWAY 2ND FLOOR - SMOKE DETECTOR MISSING (14X-5-504.8, 14X-5-504.8.4, 14B-9-907.2.10.1 THROUGH 14B-9-907.2.10.7, 14B-9-915.4.4, AND 14R-11-1104) | 5744 S GREEN ST | COMPLAINT | FAILED | View |