Chicago Building Violations Data: 59 Violations
Violation Inspector Comments Address Category Status View
REPLACE D&H PORCH COLLAPSED STAIRS FRONT PORCH MISSING TREADS AND MISSING STRINGERS OBTAIN PERMIT ONLY NO PLANS NEEDED SR800371055 1247 N PARKSIDE AVE COMPLAINT FAILED View
REPAIR DEFECTIVE FOUNDATION NORTH AND WEST FOUNDATION WALL;BROKEN AND SHIFTED 1247 N PARKSIDE AVE COMPLAINT CLOSED View
REPAIR EXTERIOR WALL EXTERIOR WALLS SIDING;LOOSE 1247 N PARKSIDE AVE COMPLAINT CLOSED View
REPAIR ROOF NORTH ELEVATION HOLE IN THE ROOF,SOUTH AND EAST ELEVATION ROOF SHINGLES DETERIORATING 1247 N PARKSIDE AVE COMPLAINT CLOSED View
UNSANITARY CONDITIONS-ANIMALS IN ROOF LINE SQUIRREL AND BIRDS NESTING 1247 N PARKSIDE AVE COMPLAINT CLOSED View
REPAIR EAVES ALL ELEVATION SOFFIT AND FASCIA BOARD;ROTTED AND BROKEN OFF 1247 N PARKSIDE AVE COMPLAINT CLOSED View
DEBRIS, EXCESSIVE YARD AREA JUNK AND DEBRIS 1247 N PARKSIDE AVE COMPLAINT CLOSED View
CUT OR REMOVE HIGH WEEDS BUILDING AND YARD AREA;HIGH WEEDS 1247 N PARKSIDE AVE COMPLAINT CLOSED View
REPAIR EXTERIOR STAIR REAR STAIR TOP RISER IMPROPER HEIGHT,STRINGER NOT SUPPORTED PROPERLY SITTING ON 4X4 AND LEANING ON HEADER,FRONT STAIR TREADS NOT LEVEL. 1247 N PARKSIDE AVE COMPLAINT CLOSED View
REPAIR FLOOR KITCHEN FLOOR TILES BROKEN,BATHROOM FLOOR ROTTED AND WESK 1247 N PARKSIDE AVE COMPLAINT CLOSED View
INT WALL/CEILING CHIP PLASTER DINING ROOM CEILING;BROKEN PLASTER [HOLE IN THE CEILING] 1247 N PARKSIDE AVE COMPLAINT CLOSED View
REPAIR INTERIOR WALLS/CEILING BASEMENT WALLS DRYWALL HAS MOLD 1247 N PARKSIDE AVE COMPLAINT CLOSED View
SUPPORT FIXTURES BASEMENT LIGHT FIXTURE;HANGING 1247 N PARKSIDE AVE COMPLAINT CLOSED View
PLANS & PERMITS REQ - CONTRCTR BASEMENT REHAB AND ALTER INTO BEDROOM;NO PLANS AND PERMITS 1247 N PARKSIDE AVE COMPLAINT CLOSED View
REPAIR EXTERIOR WALL ALL ELEVATIONS - EXTERIOR WALL SIDING LOOSE. 1247 N PARKSIDE AVE COMPLAINT FAILED View
REPAIR ROOF ALL ELEVATIONS - ROOF SHINGLES ROTTING, WRAPED AND DETERIORATING. 1247 N PARKSIDE AVE COMPLAINT FAILED View
REPAIR GUTTER & DOWNSPOUT SOUTH GUTTER AND DOWNSPOUT - LOOSE, DISCONNECTED AND MISSING SECTIONS. 1247 N PARKSIDE AVE COMPLAINT FAILED View
UNSANITARY CONDITIONS-ANIMALS ROOF LINES - SQUIRREL AND BIRDS NESTING. 1247 N PARKSIDE AVE COMPLAINT FAILED View
REPAIR EAVES ALL ELEVATIONS - SOFFIT AND FASCIA BOARDS - ROTTING AND BROKEN, WITH HOLES. 1247 N PARKSIDE AVE COMPLAINT FAILED View
CUT OR REMOVE HIGH WEEDS REAR YARD - HIGH WEEDS 1247 N PARKSIDE AVE COMPLAINT FAILED View
REPAIR GUTTER & DOWNSPOUT SOUTH GUTTER AND DOWNSPOUT - LOOSE, DISCONNECTED AND MISSING SECTIONS. 1247 N PARKSIDE AVE COMPLAINT FAILED View
REPAIR DEFECTIVE FOUNDATION NORTH AND WEST AT GRADE - FOUNDATION WALLS - BROKEN AND SHIFTED. 1247 N PARKSIDE AVE COMPLAINT FAILED View
ARRANGE COMPLETED PERMIT INSP. 1247 N PARKSIDE AVE PERMIT FAILED View
REPAIR EXTERIOR STAIR REAR STAIR SYSTEM: DETERIORATED STRINGER SYSTEM, MISSING HAND RAIL. MISSING RISERS, DETERIORATED THREADS. JUST NAILED, PERMIT REQUIRED FOR REPLACEMENT. POSTED. EMERGENCY USE ONLY 1247 N PARKSIDE AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM FRONT PORCH SYSTEM: BROKEN SECTIONS OF STRINGERS SYSTEM, UNABLE TO VERIFY ANCHOR SYSTEM OF STRINGERS MISSING RISERS, LOOSE THREAD, IMPROPER SIZE THREADS. PERMIT REQUIRED FOR REPLACEMENT CAUSING DANGEROUS AND HAZARDOUS CONDITIONS 1247 N PARKSIDE AVE COMPLAINT FAILED View
REPAIR ROOF ROOF DETERIORATED SHINGLES 1247 N PARKSIDE AVE COMPLAINT FAILED View
PROVIDE GUTTER & DOWNSPOUT DOWNSPOUTS AND GUTTERS MISSING SOUTH ELEVATION 1247 N PARKSIDE AVE COMPLAINT FAILED View
REPAIR GUTTER & DOWNSPOUT DOWNSPOUTS AND GUTTERS HANGING NORTH ELEVATION CAUSING DANGEROUS AND HAZARDOUS CONDITIONS 1247 N PARKSIDE AVE COMPLAINT FAILED View
REPAIR EXTERIOR WALL MISSING, BROKEN SECTIONS OF SIDING NORTH ELEVATION 1247 N PARKSIDE AVE COMPLAINT FAILED View
DEFECTIVE METER EQUIPMENT METER BOX NOT SUPPORTED PROPERLY HANGING BY CONDUIT RISER- 1247 N PARKSIDE AVE COMPLAINT FAILED View
SEE INSPECTOR COMMENTS PROVIDE INTERIOR INSPECTION TO VERIFY THE LOCATION AND CONDITION OF ELECTRICAL PANEL 18-27-110.3 1247 N PARKSIDE AVE COMPLAINT FAILED View
INSTALL ILLUMINATION PROVIDE ILLUMINATION FOR FRONT AND REAR EXTERIOR AREA'S- 1247 N PARKSIDE AVE COMPLAINT FAILED View
REMOVE EXTENSION CORDS BETWEEN HOUSE AND ILLEGAL SPLICE WIRES AT SERVICE HEAD FEEDING NEIGHBORS HOUSE-DANGEROUS AND HAZARDOUS CONDITION* 18-27-110.3 1247 N PARKSIDE AVE COMPLAINT FAILED View
OBTAIN ELECTRICAL PERMIT AND CONTRACTOR TO CORRECT VIOLATIONS 1247 N PARKSIDE AVE COMPLAINT FAILED View
NO SUPPLY AIR F/BSMNT/CELLAR 13-40-140 FURNACE PERMIT REQUIRED 13-32-270 1) IT SHALL BE UNLAWFUL FOR ANY PERSON TO CONSTRUCT, REPLACE OR INSTALL ANY WARM AIR HEATING FURNACE WITH APPURTENANCES, DUCTS OR REGISTERS WITHOUT FIRST OBTAINING PERMITS FROM THE COMMISSIONER OF BUILDING FOR SUCH WORK 2) EVERY APPLICATION FOR A PERMIT TO CONSTRUCT, REPLACE OR INSTALL ANY WARM AIR HEATING FURNACE SHALL BE MADE TO THE COMMISSIONER OF BUILDINGS AND SHALL BE ACCOMPANIED BY DRAWINGS OR PLANS 1247 N PARKSIDE AVE COMPLAINT FAILED View
ARRANGE COMPLETED PERMIT INSP. 18-28-106.1 INSPECTION REQUIRED 13-32-270 WARM AIR FURNACE ARRANGE FOR COMPLETE PERMIT INSPECTIONS TO OBTAIN PERMITS FOR WARM AIR HEATING SYSTEM 1247 N PARKSIDE AVE COMPLAINT FAILED View
ARRANGE COMPLETED PERMIT INSP. 1247 N PARKSIDE AVE PERMIT FAILED View
DEFECTIVE OUTLETS BASEMENT WALL OUTLET AND WAL SWITCHES;HANG OFF THE WALL 1247 N PARKSIDE AVE COMPLAINT CLOSED View
REPAIR INTERIOR STAIR SYSTEM BASEMENT INTERIOR STAIR TREADS;BROKEN 1247 N PARKSIDE AVE COMPLAINT CLOSED View
STOP STORING GARBAGE REAR YARD - JUNK AND DEBRIS ACCUMULATION. 1247 N PARKSIDE AVE COMPLAINT FAILED View
REPLCE WINDOW PANES, PLEXGLAS MISSING WINDOW PANE REAR ELEVATION (BOARDED) 1247 N PARKSIDE AVE COMPLAINT FAILED View
SECURE RACEWAY PROPERLY SUPPORT CONDUIT RISER 1247 N PARKSIDE AVE COMPLAINT FAILED View
REPAIR EAVES ALL ELEVATIONS EAVES ROTTED OUT MISSING SECTIONS 1247 N PARKSIDE AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION REFUSED ENTRY BY TENANT POSTED BACK PORCH, UNSAFE 1247 N PARKSIDE AVE COMPLAINT FAILED View
OPEN 1247 N PARKSIDE AVE PERMIT FAILED View
STOP LEAKING WATER BATHROOM TOLIET LEAKS 1247 N PARKSIDE AVE COMPLAINT CLOSED View
ARRANGE PREMISE INSPECTION REFUSED ENTRY BY TENANT 1247 N PARKSIDE AVE COMPLAINT FAILED View
PROVIDE GUARD RAIL 42 IN HIGH REAR BASEMENT TO GRADE / STAIRWAY - GUARDRAIL SECTIONS - MISSING AT GRADE. 1247 N PARKSIDE AVE COMPLAINT FAILED View
REPAIR ROOF ALL ELEVATIONS - ROOF SHINGLES ROTTING, WRAPED AND DETERIORATING. 1247 N PARKSIDE AVE COMPLAINT FAILED View
REPLACE D&H PORCH GRADE TO 1 / FRONT AND REAR PORCHES ARE IN DANGEROUS AND HAZARDOUS CONDITIONS: FRONT PORCH - STRINGERS LOOSE, SHIFTED AND BROKEN. TREADS UNLEVED, LOOSE, BROKEN AND SAGGING. RIM BEAMS SCABBED. 12X12 WOOD COLUMN BOWED. REAR PORCH - STRUCTURE PARTLY COLLAPSED, LOOSE AND DISCONNECTED. RISERS NOT UNIFORM THRU-OUT; STRINGERS SITTING ON LEANING 4X4 HEADER; 4X4 COLUMNS ERECTED ON BROKEN RETAINING WALLS WITHOUT BASES - FOUNDATION STATUS UNKNOWN. ENTIRE STRUCTURES ARE UNSAFE, UNSTABLE, LEANING AND SWAYING. PERMIT ONLY (NO PLANS) REQUIRED TO REPLACE FRONT AND REAR PORCHES. 1247 N PARKSIDE AVE COMPLAINT FAILED View
REPAIR EXTERIOR STAIR REAR BASEMENT TO GRADE / STAIRWAY - HANDRAIL - MISSING. 1247 N PARKSIDE AVE COMPLAINT FAILED View
REPAIR DEFECTIVE FOUNDATION NORTH AND WEST AT GRADE - FOUNDATION WALLS - BROKEN AND SHIFTED. 1247 N PARKSIDE AVE COMPLAINT FAILED View
STOP STORING GARBAGE REAR YARD - JUNK AND DEBRIS ACCUMULATION. 1247 N PARKSIDE AVE COMPLAINT FAILED View
PLANS & PERMITS REQ - CONTRCTR SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO BASEMENT AND 1ST FLOOR, OR RESTORE BUILDING TO THE ORIGINAL STATE. WORKING BEYOND SCOPE OF PERMIT #100650233 ISSUED ON 5/16/2016 TO: ERECT 6'-0" HIGH WOOD FENCE, DECONVERT BASEMENT PER BUILDING VIOLATIONS DATED 8/10/2011 (NO ROOMS IN BSMT) SIDING, FASCIA, EXTERIOR SOFFITS, GUTTERS, DOWNSPOUTS, PAINT, REPAIR/REPLACE DRYWALL, TILE CABINETS-ALL WORK SAME AS EXISTING SUBJECT TO FIELD INSPECTIONS. GUT REHAB ONGOING WITH PLUMBING, HVAC, FRAMING AND DRYWALL. PLANS NOW REQUIRED FOR ALL WORK. 1247 N PARKSIDE AVE COMPLAINT FAILED View
REPAIR EXTERIOR WALL ALL ELEVATIONS - EXTERIOR WALL SIDING LOOSE. 1247 N PARKSIDE AVE COMPLAINT FAILED View
REPAIR GUTTER & DOWNSPOUT SOUTH GUTTER AND DOWNSPOUT - LOOSE, DISCONNECTED AND MISSING SECTIONS. 1247 N PARKSIDE AVE COMPLAINT FAILED View
UNSANITARY CONDITIONS-ANIMALS ROOF LINES - SQUIRREL AND BIRDS NESTING. 1247 N PARKSIDE AVE COMPLAINT FAILED View
REPAIR EAVES ALL ELEVATIONS - SOFFIT AND FASCIA BOARDS - ROTTING AND BROKEN, WITH HOLES. 1247 N PARKSIDE AVE COMPLAINT FAILED View
CUT OR REMOVE HIGH WEEDS REAR YARD - HIGH WEEDS 1247 N PARKSIDE AVE COMPLAINT FAILED View