The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
ARRANGE PREMISE INSPECTION | UNABLE TO GAIN ENTRY TO VERIFY OCCUPANCY,DETECTORS AND COMPLAINT OF BEDBUGS AND ONE EXIT. | 2441 W HADDON AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | NO OWNER I.D SIGN POSTED. | 2441 W HADDON AVE | COMPLAINT | FAILED | View |
NO KEY TO USE EXIT DOOR | NORTH ELEVATION FRONT WROUGHT IRON GATE DOUBLE CYLINDER LOCK. | 2441 W HADDON AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | 1ST FLOOR APARTMENT AND ATTIC / SMOKE DETECTORS - MISSING. | 2441 W HADDON AVE | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | EAST ELEVATION / SERVICE WALK - SEVERELY CRACKED AND UNEVEN. TRIPPING HAZARD. | 2441 W HADDON AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | SOUTH ELEVATION / 3-STORY INTERIOR STAIRWAY - ALL COLUMNS ERECTED ON CONCRETE SLAB, FOUNDATION STATUS UNKNOWN; COLUMNS - ROTTING WOOD. ALL DECKING WEAK WITH ROTTING WOOD; PULLING AWAY FROM BUILDING. UPPER AND LOWER ENDS OF STRINGERS INADEQUATELY SUPPORTED AT HEADER JOISTS AND AT COLUMNS WITH NAILS ONLY. ALL RAILING SECTIONS - LOOSE, WEAK, PULLING; ATTACHED TO COLUMNS AND BUILDING'S WALLS WITH NAILS ONLY. TREADS - WORN OUT, CRACKED AND WEAK. ENTIRE INTERIOR STAIRWAY STRUCTURE - WEAK. PLANS AND PERMIT REQUIRED FOR REAR INTERIOR STAIRWAY REPLACEMENT. | 2441 W HADDON AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO ATTIC OR RESTORE BUILDING TO THE ORIGINAL STATE. | 2441 W HADDON AVE | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | REMOVE ALL PARTITIONS AND FIXTURES (INCLUDING PLUMBING AND ELECTRIC) INSTALLED IN THE ATTIC WITHOUT THE PERMIT. | 2441 W HADDON AVE | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | SOUTH ELEVATION / 3-STORY INTERIOR STAIRWAY / ALL LEVELS - ACCUMULATION OF HOUSEHOLD ITEMS, BOXES, ETC. - OBSTRUCTING PATH OF EGRESS. | 2441 W HADDON AVE | COMPLAINT | FAILED | View |
REPAIR EAVES | ALL ELEVATIONS / SOFFIT AND EAVES - ROTTING WOOD. | 2441 W HADDON AVE | COMPLAINT | FAILED | View |
RAT PROOF OPENINGS | NORTH ELEVATION SIDEWALK HAS LARGE CRACKS. | 2441 W HADDON AVE | COMPLAINT | FAILED | View |
REPAIR GUTTER | EAST AND WEST ELEVATIONS / GUTTERS - CLOGGED AND FULL OF VEGETATION. | 2441 W HADDON AVE | COMPLAINT | FAILED | View |