ARRANGE PREMISE INSPECTION | ARRANGE FOR INTERIOR INSPECTION OF BUILDING. | 4831 N MULLIGAN AVE | COMPLAINT | PASSED | View |
ADD RECEPTACLES | ADD RECEPTACLES TO EASE EXTENSION CORD USE THROUGHOUT BASEMENT AREAS | 4831 N MULLIGAN AVE | COMPLAINT | PASSED | View |
CONTINUITY OF RACEWAY | PROVIDE GROUND CONTINUITY FOR BARE WIRES TO RECEPTACLES IN BBASEMENT AND ROMEX THROUGHOUT ALL BASEMENT AND 1ST FLOOR AREAS DANGEROUS AND HAZARDOUS CONDITION | 4831 N MULLIGAN AVE | COMPLAINT | PASSED | View |
INSTALL COVERS | PROVIDE PROPER TYPE COVERS FOR OPEN JUNCTION BOXES THROUGHOUT ALL BASEMENT AREAS | 4831 N MULLIGAN AVE | COMPLAINT | PASSED | View |
SECURE RACEWAY | PROPERLY SUPPORT ALL BOXES AND CONDUIT RUNS THROUGHOUT ALL BASEMENT AEAS | 4831 N MULLIGAN AVE | COMPLAINT | PASSED | View |
GROUND EQUIPMENT | PROVIDE A WATER MAIN GROUND CONDUCTOR TO WITHIN 5' OF WATER METER OR VALVE | 4831 N MULLIGAN AVE | COMPLAINT | PASSED | View |
SEE INSPECTOR COMMENTS | PROVIDE GFCI PROTECTION FOR ALL KITCHEN COUNTERTOP AREAS,BATHROOM AND LAUNDDRY AREAS 18-27-210.8 | 4831 N MULLIGAN AVE | COMPLAINT | PASSED | View |
NO PERMIT WIRING | OBTAIN ELECTRICAL PERMIT AND CONTRACTOR TO CORRECT VIOLATIONS AND FOR INSTALLATION OF NEW PANEL AND SUB PANEL WITHOUT PLANS AND PERMITS | 4831 N MULLIGAN AVE | COMPLAINT | PASSED | View |