Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
MULTIPLE CONDUCTOR TERM | MULTIPLE CONDUCTORS UNDER SINGLE BROKERS | 2331 S MILLARD AVE | COMPLAINT | PASSED | View |
DEFECTIVE DISTRIBUTION | DEFECTIVE PANELS USED AS RACEWAY'S NEUTRAL NOT BONDED | 2331 S MILLARD AVE | COMPLAINT | PASSED | View |
REPAIR DEFECTIVE FITTINGS | (18-29-102.3) KITCHEN SINK 5-TRAP BSMT APT. | 2331 S MILLARD AVE | COMPLAINT | FAILED | View |
REPAIR DEFECTIVE FITTINGS | (18-29-102.3) 1ST FL BATH TUB 5-TRAP | 2331 S MILLARD AVE | COMPLAINT | FAILED | View |
RESET LOOSE FIXTURE | (18-29-102.3) BSMT TOILET | 2331 S MILLARD AVE | COMPLAINT | FAILED | View |
PRV FLUE FOR HOT WATER HEATER | (13-152-400) SECURE HOOD & FLUE PIPE | 2331 S MILLARD AVE | COMPLAINT | FAILED | View |
INSTALL FIXTURES PROPER MATERL | (18-29-402) REMOVE MISSING COUP ON 1ST FL TUB | 2331 S MILLARD AVE | COMPLAINT | FAILED | View |
TEST ALTERED SYSTEM | (18-29-312) SR# | 2331 S MILLARD AVE | COMPLAINT | FAILED | View |
DEFECTIVE FEEDER | BRANCH CIRCUIT WIRING ILLEGAL USE OF NEUTRAL (ALL WHITE WIRING ) | 2331 S MILLARD AVE | COMPLAINT | PASSED | View |
DEFECTIVE POWER SERVICE | SE SERVICE RISER NOT STRAPPED | 2331 S MILLARD AVE | COMPLAINT | PASSED | View |
CIRCUIT ONE UNIT ONLY | 18-27-210.25 PROVIDE SEPARATE PANEL AND METERING TO FEED ALL BUILDING COMMON AREA LOADS | 2331 S MILLARD AVE | COMPLAINT | PASSED | View |
PROPER SIZE GRD ELECTRODE COND | SERVICE AND PANELS IMPROPERLY GROUNDED | 2331 S MILLARD AVE | COMPLAINT | PASSED | View |
DEFECTIVE METER EQUIPMENT | RUSTED AND ILLEGAL SPLICES AND TAP IN METER SOCKET | 2331 S MILLARD AVE | COMPLAINT | PASSED | View |
CORD TO FIXTURE | RANGE HOOD | 2331 S MILLARD AVE | COMPLAINT | PASSED | View |
CORRODED CONDUIT & EQUIP | 2331 S MILLARD AVE | COMPLAINT | PASSED | View | |
CONTINUITY OF RACEWAYS | 2331 S MILLARD AVE | COMPLAINT | PASSED | View | |
SECURE RACEWAY | 2331 S MILLARD AVE | COMPLAINT | PASSED | View | |
ACCESS TO JBS | 2331 S MILLARD AVE | COMPLAINT | PASSED | View | |
TENANT ACCESS TO SERVICE | 2331 S MILLARD AVE | COMPLAINT | PASSED | View | |
SEE INSPECTOR COMMENTS | 18-27-570.8 PROVIDE GFCI PROTECTION ALL KITCHENS AND BATHS | 2331 S MILLARD AVE | COMPLAINT | PASSED | View |
DEFECTIVE OUTLETS | 2331 S MILLARD AVE | COMPLAINT | PASSED | View | |
SUPPORT OUTLET AND JBOX | 2331 S MILLARD AVE | COMPLAINT | PASSED | View | |
INSTALL COVERS | 2331 S MILLARD AVE | COMPLAINT | PASSED | View | |
POST OWNER/MANAGERS NAME/# | SR#702383398-OWNER'S I.D SIGN IS NOT POSTED | 2331 S MILLARD AVE | COMPLAINT | PASSED | View |
NO KEY TO USE EXIT DOOR | FRONT/REAR GATES-DOUBLE KEYS CYLINDER LOCKS | 2331 S MILLARD AVE | COMPLAINT | PASSED | View |
REPAIR EXTERIOR WALL | NORTH-ERODED MORTAR, SPALLED BRICKS | 2331 S MILLARD AVE | COMPLAINT | PASSED | View |
CHIMNEY | SOUTH-(2) CHIMNEYS-ERODED MORTAR, MISSING, CAPS | 2331 S MILLARD AVE | COMPLAINT | PASSED | View |
REPAIR PORCH SYSTEM | FRONT-BEAM POCKETS ARE MISSING MORTAR POTTED ROOF COLUMNS. ROTTED JOISTS. ONLY PERMIT IS REQUIRED FOR REPAIRS | 2331 S MILLARD AVE | COMPLAINT | PASSED | View |
REPAIR WINDOW SILLS | SOUTH-ERODED MORTAR,REAR ENCLOSED PORCH-FEW ROTTED | 2331 S MILLARD AVE | COMPLAINT | PASSED | View |
REPLCE WINDOW PANES, PLEXGLAS | ALL ELEVATIONS-SEVERAL BROKEN PANES | 2331 S MILLARD AVE | COMPLAINT | PASSED | View |
MAINTAIN WINDOW SASH | SOUTH AT (2) REAR PORCH-BROKEN SASH | 2331 S MILLARD AVE | COMPLAINT | PASSED | View |
MAINTAIN WINDOW | REAR PORCH/NORTH AT (2)REAR-PEELING PAINT | 2331 S MILLARD AVE | COMPLAINT | PASSED | View |
REPUTTY WINDOW PANES | REAR PORCH/NORTH AT (2)REAR-LOOSE,CRACKED AND MISSING PUTTY | 2331 S MILLARD AVE | COMPLAINT | PASSED | View |
REPLACE D&H PORCH | REAR ENCLOSED PORCH-COLUMNS ARE PULLING AWAY FROM THE BEAMS,CENTER COLUMN AND CENTER/NORTH BEAMS IS ONLY SUPPORTED BUY 2 2X8 MEMBERS AT GRADE STRINGERS ARE NOT BOLTED INTO THE STRUCTURE OR NEWEL POSTS LOOSE TREADS, SCABBED WINDERS,STAIRS AND LANDING AT(3) ARE EXCESSIVELY PITCHED IMPROPER CONNECTIONS-MOST MEMBERS ARE ONLY TOE NAILED TOGETHER, SIGN POSTED FOR DANGEROUS AND HAZARDOUS CONDITIONS, SUBMIT PLANS AND OBTAIN PERMIT TO REPLACE REAR PORCH | 2331 S MILLARD AVE | COMPLAINT | PASSED | View |
FLAM LIQ TANK FRONTAGE CONSENT | REAR PORCH AT GRADE-LOW MOWER AND STEEL CYLINDER TANK FILLED WITH AN UNKNOWN SUBSTANCE | 2331 S MILLARD AVE | COMPLAINT | PASSED | View |
RATS | REAR PORCH AT GRADE-LARGE AMOUNT OF RAT DROPPINGS ADJACENT THE CATCH BASIN | 2331 S MILLARD AVE | COMPLAINT | PASSED | View |
INSTALL SMOKE DETECTORS | REAR PORCH AT (3)-MISSING DETECTOR | 2331 S MILLARD AVE | COMPLAINT | PASSED | View |
DEBRIS, EXCESSIVE | REAR PORCH AT (3)-EXCESSIVE AMOUNT OF PERSONAL ITEM INCLUDING A CLOTHES DRYER | 2331 S MILLARD AVE | COMPLAINT | PASSED | View |
DEFECTIVE OUTLETS | REAR PORCH AT (3)-FIRE DAMAGED OUTLET | 2331 S MILLARD AVE | COMPLAINT | PASSED | View |
REPAIR INTERIOR WALLS/CEILING | REAR PORCH AT (3)-DRY WALLED CEILING IS DAMAGED | 2331 S MILLARD AVE | COMPLAINT | PASSED | View |
ARRANGE PREMISE INSPECTION | BUILDING INTERIOR-NO RESPONSE, UNVERIFIED DETECTORS,OCCUPANCY AND CONDITIONS, UNVERIFIED COMPLAINT OF ONE ENTRANCE | 2331 S MILLARD AVE | COMPLAINT | PASSED | View |
ILLUMINATE EXIT AREAS | REAR PORCH AT (3)-LIGHTING IS OUT OF SERVICE | 2331 S MILLARD AVE | COMPLAINT | PASSED | View |
BOX UNUSED OPENINGS | PANELS | 2331 S MILLARD AVE | COMPLAINT | PASSED | View |
SEE INSPECTOR COMMENTS | 2331 S MILLARD AVE | PERMIT | FAILED | View | |
PROVIDE ADEQUATE SUPPORT | (18-29-303.2) 1ST FL BATH WASTE | 2331 S MILLARD AVE | COMPLAINT | FAILED | View |