Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPLCE WINDOW PANES, PLEXGLAS | 1ST 2ND FLOOR FRONT WINDOW BROKEN PANES | 7037 S EGGLESTON AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | FRONT PORCH LOOSE HAND RAILS ON BOTH SIDE BROKEN TREADS | 7037 S EGGLESTON AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | 1ST FLOOR BATHROOM WALL AND CEILING BROKEN PLASTER WITH LARGE HOLES | 7037 S EGGLESTON AVE | COMPLAINT | FAILED | View |
REPAIR FLOOR | 1ST AT FLOOR KITCHEN FLOOR ROTTING WOOD WITH MISSING TILES | 7037 S EGGLESTON AVE | COMPLAINT | FAILED | View |
INSTALL DOOR VIEWING DEVICE | 1ST 2ND FLOOR APARTMENTS MISSING VIEWING DEVICE | 7037 S EGGLESTON AVE | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | AROUND BUILDING JUNKS AT DEBRIS | 7037 S EGGLESTON AVE | COMPLAINT | FAILED | View |
CHIMNEY CAPPING | CHIMNEY MISSING CONCRETE CAP | 7037 S EGGLESTON AVE | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | SOUTH SERVICE WALK BROKEN CONCRETE TRIPPING HAZARD | 7037 S EGGLESTON AVE | COMPLAINT | FAILED | View |
REPAIR FENCE | FRONT FENCE GATE BROKEN WITH MISSING & HINGES | 7037 S EGGLESTON AVE | COMPLAINT | FAILED | View |
SUPPLY HOT WTR MIN TEMP 120DEG | NO HOT WATER AT 1ST FLOOR UNIT | 7037 S EGGLESTON AVE | COMPLAINT | FAILED | View |
REPLACE DEFECTIVE WASTE PIPING | MISSING OVERFLOW AT BATHTUB 1ST FLOOR | 7037 S EGGLESTON AVE | COMPLAINT | FAILED | View |
REPLACE DEFECTIVE FAUCET | KITCHEN SINK FAUCET LEAKS UNDER CABINET | 7037 S EGGLESTON AVE | COMPLAINT | FAILED | View |
STOP ODORS RPR DFT SEWAGE SYS | SEWER GASES PRESENT AT 1ST FLOOR UNIT MAY BE COMING FROM BASEMENT | 7037 S EGGLESTON AVE | COMPLAINT | FAILED | View |
ENGAG LIC & BOND PLMBNG CNTRC | A LICENSED & BONDED PLUMBING CONTRACTOR IS REQUIRED | 7037 S EGGLESTON AVE | COMPLAINT | FAILED | View |
SUPPORT FIXTURES | 1ST FLOOR HANGING LIGHT BEDROOM | 7037 S EGGLESTON AVE | COMPLAINT | FAILED | View |
EXPOSED WIRING | EXPOSE WIRE LIVING ROOM SWITCH AREA | 7037 S EGGLESTON AVE | COMPLAINT | FAILED | View |
STAIRWELL ENCLOSURE - BASEMENT | BASEMENT - WOOD, LATH AND PLASTER DOES NOT PROVIDE A (1) ONE HOUR FIRE RATING | 7037 S EGGLESTON AVE | COMPLAINT | CLOSED | View |
SEPARATION OF DWELLING ADEQUAT | BASEMENT - PROVIDE A (1) ONE HOUR FIRE RATING FOR DWELLING SEPARATION | 7037 S EGGLESTON AVE | COMPLAINT | CLOSED | View |
CONTRARY TO ORIGINAL PLAN | BASEMENT STORAGE SPACE HAS BEEN CONVERTED TO (2) TWO FAMILY UNITS. | 7037 S EGGLESTON AVE | COMPLAINT | CLOSED | View |
WORK NOT ALLOWED | BASEMENT - RESTORE SPACE TO ITS ORIGINAL CONFIGURATION | 7037 S EGGLESTON AVE | COMPLAINT | CLOSED | View |
PLANS & PERMITS REQ - CONTRCTR | BASEMENT - SUBMIT PLANS AND PERMIT FOR DECONVERSION | 7037 S EGGLESTON AVE | COMPLAINT | CLOSED | View |
FOUNDATION FOR FURNACE/BOILER | 2ND FLOOR HEATING UNIT MISSING FOUNDATION FOR FORCED AIR UNIT | 7037 S EGGLESTON AVE | COMPLAINT | CLOSED | View |
CEILING HEIGHT - 7' - BASEMENT | BASEMENT - CEILING HEIGHT IS LESS THAN 7 FT. | 7037 S EGGLESTON AVE | COMPLAINT | CLOSED | View |
WINDOW AREA ABOVE GROUND | BASEMENT - PROVIDE (8) EIGHT PERCENT NATURAL LIGHT AND 4 PERCENT VENTILATION | 7037 S EGGLESTON AVE | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR WALL | SOUTH ELEVATION AT GRADE - ERODED MORTAR JOINT | 7037 S EGGLESTON AVE | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR DOOR FRAME | 2ND FLOOR DOOR FRAME FRONT BROKEN | 7037 S EGGLESTON AVE | COMPLAINT | CLOSED | View |
REPLCE WINDOW PANES, PLEXGLAS | 2ND FLOOR PORCH - WINDOW PANES MISSING | 7037 S EGGLESTON AVE | COMPLAINT | CLOSED | View |
STOP/REMOVE NUISANCE | 2ND FLOOR VACANT AND OPEN - DANGER | 7037 S EGGLESTON AVE | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR DOOR HARDWARE | REAR DOOR TO 1ST FLOOR MISSING DOORKNOB | 7037 S EGGLESTON AVE | COMPLAINT | CLOSED | View |
INSTALL SMOKE DETECTORS | ALL APARTMENTS - NO SMOKE DETECTORS AND HEAT BASEMENT | 7037 S EGGLESTON AVE | COMPLAINT | CLOSED | View |
REPAIR FENCE | FRONT SERVICE WALK GATE OFF HINGE POST OF FENCE | 7037 S EGGLESTON AVE | COMPLAINT | CLOSED | View |
OBSTRUCTIONS IN EXIT WAY | REAR PORCH - REMOVE OLD REFRIGERATOR, OBSTRUCTION OF EGRESS | 7037 S EGGLESTON AVE | COMPLAINT | CLOSED | View |
CARB MONOX DETECT IN RESID | ALL APARTMENTS MISSING CARBON MONOXIDE DETECTORS | 7037 S EGGLESTON AVE | COMPLAINT | CLOSED | View |
CONNECT GAS APPLIANCE TO VENT | HEAT FLUE NOT CONNECTED TO CHIMNEY - DANGER | 7037 S EGGLESTON AVE | COMPLAINT | CLOSED | View |
REPLACE DEFECTIVE PLBG FIXTURE | BROKEN LAVATORY VANITY 1ST FLOOR | 7037 S EGGLESTON AVE | COMPLAINT | CLOSED | View |
PRV WATER AT PLUMBING FIXTURE | LOW HOT WATER PRESSURE THROUGHOUT HOUSE | 7037 S EGGLESTON AVE | COMPLAINT | CLOSED | View |
RMV PLBFIX INSTALLD W/0 PERMIT | REMOVE ALL PLUMBING AND RELATED PIPING ILLEGALLY AND IMPROPERLY INSTALLED WITHOUT PERMIT AT 2 BASEMENT UNITS. | 7037 S EGGLESTON AVE | COMPLAINT | CLOSED | View |
PRV DISCHARGE PIPE FROM PRV | PROPERLY SIZE RELIEF VALVE DISCHARGE PIPE AT (1) WATER HEATER PRESENTLY 1/2" SIZE. | 7037 S EGGLESTON AVE | COMPLAINT | CLOSED | View |
CONNECT GAS APPLIANCE TO VENT | DISCONNECTED FLUE AT MAIN TRUNK LINE. PICKING UP 3 WATER HEATERS AND FURNACE IN BASEMENT. | 7037 S EGGLESTON AVE | COMPLAINT | CLOSED | View |
PRV WATER PIPES PROPER SIZE | PROPERLY SIZE WATER SUPPLY PIPES IN BASEMENT. SUSPENDED PIPING. DANGEROUS AND HAZARDOUS. | 7037 S EGGLESTON AVE | COMPLAINT | CLOSED | View |
CONNECT DOWNSPOUT TO SEWER | CONNECT DOWNSPOUT TO SEWER IN REAR | 7037 S EGGLESTON AVE | COMPLAINT | CLOSED | View |
OBTAIN PERMIT FOR PLUMBING | TO CORRECT ALL PLUMBING VIOLATIONS | 7037 S EGGLESTON AVE | COMPLAINT | CLOSED | View |
ENGAG LIC & BOND PLMBNG CNTRC | A LICENSED AND BONDED PLUMBING CONTRACTOR IS REQUIRED. | 7037 S EGGLESTON AVE | COMPLAINT | CLOSED | View |
DEFECTIVE METER EQUIPMENT | METER BOX COVER MISSING | 7037 S EGGLESTON AVE | COMPLAINT | CLOSED | View |
SEE INSPECTOR COMMENTS | RAINTITE FITTINGS MISSING ON SIDE OF METER BOX (18-27-230.54)A&G | 7037 S EGGLESTON AVE | COMPLAINT | CLOSED | View |
DEFECTIVE FIXTURES | BROKEN LITE FIXTURE TOP OF STAIRS GOING DOWN | 7037 S EGGLESTON AVE | COMPLAINT | CLOSED | View |
DEFECTIVE FIXTURES | BAD FIXTURE ENTRY WAY 1ST FLOOR | 7037 S EGGLESTON AVE | COMPLAINT | CLOSED | View |
DEFECTIVE FIXTURES | BAD FIXTURE BACK PORCH 2ND FLOOR | 7037 S EGGLESTON AVE | COMPLAINT | CLOSED | View |