The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR PORCH SYSTEM | REAR PORCH MISSING BOLTS FROM LEDGER BOARDS LOOSE RAILS 2ND TO 3RD FLOOR, NO PLANS NEEDED NO PERMIT NEEDED TO REPAIR | 7411 S EGGLESTON AVE | PERIODIC | FAILED | View |
INSTALL SMOKE DETECTORS | MISSING DETECTOR FRONT STAIRWAY | 7411 S EGGLESTON AVE | PERIODIC | FAILED | View |
INSTALL DOOR VIEWING DEVICE | INTERIOR DOOR/PEEPHOLES MISSING | 7411 S EGGLESTON AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH FOOTING CONCRETE BLOCKS ALUMINUM STEPS AT COLUMN SPLICE UNDER 2X10 BEAM NAILED TO COLUMN AND RIM JOIST GUARDRAIL NAILED TO BUILDING REPAIR PERMIT NEEDED FOR COLUMNS WORK | 7411 S EGGLESTON AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | REAR ROTTED SIDING | 7411 S EGGLESTON AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | REAR BEAM ROTTED 2X4 DOUBLE ACTING AS COLUMN SUPPORTING ADDITION | 7411 S EGGLESTON AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | NORTH WALL SPALLING BRICKS | 7411 S EGGLESTON AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR DOOR HARDWARE | FRONT EXTERIOR/DOOR/LOCK NOT WORKING | 7411 S EGGLESTON AVE | PERIODIC | FAILED | View |
INSTALL SMOKE DETECTORS | SMOKE DETECTOR IS MISSING IN BASEMENT DWELLING UNIT. | 7411 S EGGLESTON AVE | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | BUILDING HAS NOT BEEN REGISTERED FOR YEARS 2010 THRU 2012. | 7411 S EGGLESTON AVE | PERIODIC | FAILED | View |
CARB MONOX DETECT IN RESID | CARBON MONOXIDE DETECTOR IS MISSING IN BASEMENT DWELLING UNIT. | 7411 S EGGLESTON AVE | PERIODIC | FAILED | View |
REPLACE D&H PORCH | BUILDING REAR 3 STORY WOOD PORCH WITH EXPOSED STAIRS BEING USED AS LIVING AREA. 6X6 COLUMNS ON STAIRS DOUBLE CUT FOR RIM JOISTS AND BEAMS, COLUMNS ARE STACKED AT 2ND FLOOR LEVEL. SOUTH CORNER 6X6 COLUMN IS ROTTED AT GRADE, COLUMNS ERECTED ON CONCRETE BLOCKS AND SIDEWALKS. STAIRS STRINGERS ARE ATTACHED TO BEAMS AND JOISTS BY THE CLEATS, SOME STRINGERS WITH BROKEN CLEATS. GUARD RAILS NOT PROPERLY SUPPORTED, ATTACHED TO COLUMNS WITH SCREWS ONLY WEAK AND LOOSE. STAIRS SYSTEM MOVES WHEN WALKED ON. 32' FOOT WIDE PORCH IS BEING SUPPORTED ON ONLY 3- 6X6 COLUMNS. AT 1ST FLOOR LEVEL A SINGLE 2X8 BEAM BEING USED TO SUPPORT FLOOR JOISTS (SOME ARE DOUBLE) ON JOIST HANGERS NOT PROPERLY NAILED ARE PULLING AWAY FROM THE BEAM. MANY ROTTED FLOOR JOISTS VISIBLE ON 1ST FLOOR. DANGEROUS POSTED PLANS AND PERMIT REQUIRED FOR REPLACEMENT. | 7411 S EGGLESTON AVE | PERIODIC | FAILED | View |
STOP/REMOVE NUISANCE | JUNK STOVE AND RADIATOR ON 3RD FLOOR PORCH | 7411 S EGGLESTON AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR DOOR HARDWARE | FRONT EXTERIOR/DOOR/LOCK NOT WORKING | 7411 S EGGLESTON AVE | PERIODIC | FAILED | View |
INSTALL DOOR VIEWING DEVICE | INTERIOR DOOR/PEEPHOLES MISSING | 7411 S EGGLESTON AVE | PERIODIC | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | BROKEN GLASS BLOCK UNITS IN BASEMENT WINDOWS. | 7411 S EGGLESTON AVE | PERIODIC | FAILED | View |