The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
SCREEN OUTER DOORS, WINDOWS | BUILDING / SCREENS - TORN AT VARIOUS LOCATIONS. | 2201 E 70TH ST | PERIODIC | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | 2201 / INTERIOR STAIRWAY CEILING AT SKYLIGHT - WATER DAMAGE. | 2201 E 70TH ST | PERIODIC | FAILED | View |
ARRANGE FOR REINSPECTION REGAR | INTERIOR OF MOST APTS. - NO ENTRY, UNVERIFIED DETECTORS AND CONDITIONS. | 2201 E 70TH ST | PERIODIC | FAILED | View |
REPAIR FLOOR | 7009 / APT 1 / HALLWAY - SAGGING OUT OF LEVEL. | 2201 E 70TH ST | PERIODIC | FAILED | View |
INT WALL/CEILING CHIP PLASTER | 7009 / APT 1 / BATHROOM WALLS AND CEILING - BUBBLING PAINT WITH BLACK SUBSTANCE OBSERVED. | 2201 E 70TH ST | PERIODIC | FAILED | View |
REPAIR OR REPLACE | 7004 / APT 1 / KITCHEN CABINETS - DAMAGED DRAWERS AND UNDER SINK. | 2201 E 70TH ST | PERIODIC | FAILED | View |
CARPETING | 7009 / APT 1 / CARPETING - TORN AT HALLWAY. | 2201 E 70TH ST | PERIODIC | FAILED | View |
REPAIR LINTELS | WEST AND NORTH ELEVATION LINTELS - RUSTED AND DEFLECTING, SOME LINTELS ARE 7 FEET IN LENGTH, PLANS AND MASONRY PERMIT REQUIRED. | 2201 E 70TH ST | PERIODIC | FAILED | View |
REPAIR FLOOR | 7001 S. / APT - 1 / KITCHEN FLOOR - BROKEN AND MISSING TILES. | 2201 E 70TH ST | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | EAST ELEVATION / 3 - 3 STORY WOOD PORCHES / 6X6 COLUMNS OVERNOTCHED 3 INCHES FOR DOUBLE 2X8 BEAM. COLUMNS - TWISTING AND BOWING. 6X6 COLUMNS ERECTED ON CONCRETE BLOCKS. COLUMN BASES PLATES ARE RUSTED. FOUNDATION STATUS UNKNOWN. HALF LAP JOINTS - ONLY 12 INCHES LONG. 2ND FLOOR COLUMN HALF LAP JOINTS ARE LOCATED AT TOP OF 2ND FLOOR DECK. 4 FOOT 6X6 COLUMN HALF LAP JOINT IS AT TOP OF 3RD FLOOR DECK . ENTIRE TOP SECTION OF COLUMN EXTREMELY LOOSE AND UNSTABLE. 2X8 JOISTS ARE 19 INCHES ON CENTER. STAIR TREADS ARE ONLY 9 1/4 INCHES WIDE. ALL RAIL SECTIONS FASTENED WITH NAILS ONLY. GUARD RAIL SECTIONS SPAN UP TO 7 FEET. GUARD RAILS WORN AND ROTTEN. GUARD RAILS HAVE GREEN SUBSTANCE ON ALL RAIL SECTIONS. 3RD FLOOR GUARD RAIL LOOSE AND UNSTABLE AT 7001 S. ALL DEFICIECIES APPLY TO 3 - 3 STORY WOOD PORCHES. PLANS AND PERMIT REQUIRED FOR ALL PORCH REPAIRS. | 2201 E 70TH ST | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | NO RESPONSE TO MOST UNITS, PORCH, AND DETECTORS. | 2201 E 70TH ST | PERIODIC | FAILED | View |
PERMIT REQUIRED | REAR FENCE OVER 5' PERMIT REQUIRED. | 2201 E 70TH ST | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | PROVIDE EVIDENCE OF BUILDING REGISTRATION FOR YEARS 2012. | 2201 E 70TH ST | PERIODIC | FAILED | View |
REPAIR LINTELS | WEST AND NORTH ELEVATION LINTELS - RUSTED AND DEFLECTING, SOME LINTELS ARE 7 FEET IN LENGTH, PLANS AND MASONRY PERMIT REQUIRED. | 2201 E 70TH ST | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | SOUTH ELEVATION UNDER 3RD FLOOR WINDOW - SPALLING BRICKS AND WASHED OUT MORTAR. | 2201 E 70TH ST | PERIODIC | FAILED | View |
NO POSTED ADDRESS | NORTH ELEVATION - POSTED ADDRESS IS MISSING NUMBER. | 2201 E 70TH ST | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING - NO RESPONSE, UNVERIFIED DETECTORS AND CONDITIONS. UNABLE TO VERIFY COMPLAINT OF SEWAGE SMELL THROUGHOUT BUILDING. NO ACCESS TO INSPECT REAR PORCHES. | 2201 E 70TH ST | PERIODIC | FAILED | View |
REPAIR LINTELS | WEST AND NORTH ELEVATION LINTELS - RUSTED AND DEFLECTING, SOME LINTELS ARE 7 FEET IN LENGTH, PLANS AND MASONRY PERMIT REQUIRED. | 2201 E 70TH ST | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | EAST ELEVATION / 3 - 3 STORY WOOD PORCHES / 6X6 COLUMNS OVERNOTCHED 3 INCHES FOR DOUBLE 2X8 BEAM. COLUMNS - TWISTING AND BOWING. 6X6 COLUMNS ERECTED ON CONCRETE BLOCKS. COLUMN BASES PLATES ARE RUSTED. FOUNDATION STATUS UNKNOWN. HALF LAP JOINTS - ONLY 12 INCHES LONG. 2ND FLOOR COLUMN HALF LAP JOINTS ARE LOCATED AT TOP OF 2ND FLOOR DECK. 4 FOOT 6X6 COLUMN HALF LAP JOINT IS AT TOP OF 3RD FLOOR DECK . ENTIRE TOP SECTION OF COLUMN EXTREMELY LOOSE AND UNSTABLE. 2X8 JOISTS ARE 19 INCHES ON CENTER. STAIR TREADS ARE ONLY 9 1/4 INCHES WIDE. ALL RAIL SECTIONS FASTENED WITH NAILS ONLY. GUARD RAIL SECTIONS SPAN UP TO 7 FEET. GUARD RAILS WORN AND ROTTEN. GUARD RAILS HAVE GREEN SUBSTANCE ON ALL RAIL SECTIONS. 3RD FLOOR GUARD RAIL LOOSE AND UNSTABLE AT 7001 S. ALL DEFICIECIES APPLY TO 3 - 3 STORY WOOD PORCHES. PLANS AND PERMIT REQUIRED FOR ALL PORCH REPAIRS. | 2201 E 70TH ST | PERIODIC | FAILED | View |
REPAIR DOOR FRAME, MULLION | 7009 S. / APT. - 2 / BATHROOM DOOR - JAMB ROTTEN AND MISSING STRIKE PLATE. | 2201 E 70TH ST | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | PROVIDE EVIDENCE OF BUILDING REGISTRATION FOR YEARS 2012. | 2201 E 70TH ST | PERIODIC | FAILED | View |
REPAIR OR REPLACE | 7009 S. / APT - 1 / BATHROOM VANITY - MISSING DOOR. | 2201 E 70TH ST | PERIODIC | FAILED | View |