Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-08-30 @ 5:26 PM
PIN: 21314240200000
Property Address: 8610 S EXCHANGE AVE
City - Zip: CHICAGO - 60617
2023 Property Class: 241
2023 Township: 70 - Hyde Park
2023 Neighborhood: 70100
2023 Tax District: 70001
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 17 Violations
Violation Inspector Comments Address Category Status View
REPAIR INTERIOR WALLS/CEILING PAINT FLAKING.BASEBOARD LOOSE. 8610 S EXCHANGE AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION NO ENTRY. UNVERIFIED DETECTORS AND CONDITIONS. 8610 S EXCHANGE AVE COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# BUILDING OWNER'S ID. SIGN NOT POSTED. 8610 S EXCHANGE AVE COMPLAINT FAILED View
REPAIR SCREENS ALL ELEVATIONS /SCREENS - RIPPED - MISSING; 8610 S EXCHANGE AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION INTERIOR OF BUILDING ¿ NO RESPONSE;UNABLE TO VERIFY DETECTORS, CONDITIONS AND OCCUPANCY;UNABLE TO INSPECT INTERIOR STAIRWAY, BASEMENT, ATTIC; NOTE: OPEN VIOLATIONS - 08-23-10 - A/P# 264065; 8610 S EXCHANGE AVE COMPLAINT FAILED View
REPAIR LINTELS FRONT AND NORTH ELEVATION 1ST. AND 2ND. FL.] /METAL BALCONY LINTEL /"I" BEAM - BENT, SAGGING, WITH GAPS ABOVE IT;GARAGE /OVER-HEAD DOOR /METAL LINTEL /"I" BEAM - BENT, SAGGING, WITH GAPS ABOVE IT;PLANS AND MASONRY PERMIT REQUIRED; 8610 S EXCHANGE AVE COMPLAINT FAILED View
REPAIR/REBUILD GARAGE OR SHED GARAGE /OVER-HEAD DOOR /METAL LINTEL /"I" BEAM - BENT, SAGGING, WITH GAPS ABOVE IT; SOUTH ELEVATION /EXTERIOR WALL AND PARAPET WALL - OUT OF PLUMB - LEANING INWARD; EAST ELEVATION /EXTERIOR WALL AND PARAPET WALL - WASHED OUT MORTAR; EAST ELEVATION /SERVICE DOOR - ROTTED;PLANS AND MASONRY PERMIT REQUIRED; 8610 S EXCHANGE AVE COMPLAINT FAILED View
REPAIR STOOP FRONT ELEVATION /STONE STOOP - STEP - CRACKED WITH LARGE HOLE; 8610 S EXCHANGE AVE COMPLAINT FAILED View
REPAIR GUTTER & DOWNSPOUT ALL ELEVATIONS /ROOF GUTTERS AND DOWNSPOUTS - RUSTED WITH HOLES, DEBRIS; 8610 S EXCHANGE AVE COMPLAINT FAILED View
REPAIR WINDOW SILLS FRONT AND SOUTH ELEVATION /STONE WINDOW SILLS - WASHED OUT MORTAR; 8610 S EXCHANGE AVE COMPLAINT FAILED View
REPAIR BALCONY FRONT ELEVATION /1ST. FL. [UNDERSIDE] BALCONY - WOOD - WATER DAMAGE - ROTTED;FRONT AND NORTH ELEVATION 1ST. AND 2ND. FL.] /METAL BALCONY LINTEL /"I" BEAM - BENT, SAGGING, WITH GAPS ABOVE IT;PLANS AND MASONRY PERMIT REQUIRED; 8610 S EXCHANGE AVE COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# BUILDING /OWNER¿S I.D. SIGN ¿ MISSING; 8610 S EXCHANGE AVE COMPLAINT FAILED View
REPAIR EAVES ALL ELEVATIONS /EAVES, SOFFIT, FASCIA - ROTTED; 8610 S EXCHANGE AVE COMPLAINT FAILED View
REPAIR EXTERIOR WALL FRONT ELEVATION /EXTERIOR WALL [AT 1ST. FL. BALCONY METAL LINTEL /"I" BEAM] - FRACTURED WASHED OUT MORTAR; WING WALL - LOOSE, SHIFTED, FRACTURED, WASHED OUT MORTAR; NORTH ELEVATION /EXTERIOR WALL [AT FRONT PORCH] - FRACTURED WASHED OUT MORTAR; NORTHEAST ELEVATION /EXTERIOR [PIER] WALL [AT BALOCNY] - SHIFTED, FRACTURED, WASHED OUT MORTAR;MASONRY PERMIT REQUIRED; 8610 S EXCHANGE AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM REAR ELEVATION /2 STORY WOOD BALCONY WITH ROOF;FOUNDATIONS /BASES FORMED BY CONCRETE POURED IN AROUND COLUMN; FOUNDATION STATUS UNKNOWN;COLUMNS /6X6 COLUMNS STACKED UP ON TOP OF ONE ANOTHER, FASTENED WITH NAILS ONLY; COLUMNS /INADEQUATE HALF-LAP JOINTS WITH OVERLAP OF ONLY 6 INCHES, WITH ONLY 2 BOLTS; ; COLUMNS /OVER NOTCHED WITH FIRE CUTS AND RIM JOISTS CONNECTIONS OCCURRING AT THE SAME LOCATION OR IN CLOSE PROXIMITY AND ONLY 4 INCHES APART; SOUTHWEST ELEVATION /6X6 - WAVY; ALL CONNECTIONS - GAPS UP TO 1/2 INCH;LEDGER BEAMS /ATTACHED TO BUILDING EXTERIOR WALLS, WITH NAILS ONLY; BEAMS /PULLING OUT OF FIRE CUTS; IMPROPERLY SUPPORTED AT FIRE CUTS; BEAMS TOE NAILED TO COLUMNS; DECK JOISTS /UNDERSIZED 2X8 DECK JOISTS SPAN 8 FEET 10 INCHES; RAILINGS /ALL RAILING SECTIONS FASTENED TO COLUMNS AND EXTERIOR WALL WITH NAILS /SCREWS ONLY; ROOF CONNECTION MUST BE ON PLANS;PLANS AND PERMIT REQUIRED; 8610 S EXCHANGE AVE COMPLAINT FAILED View
REPAIR FENCE FRONT ELEVATION /METAL GATE - OFF HINGES; 8610 S EXCHANGE AVE COMPLAINT FAILED View
RAT STOP AROUND EXTERIOR FRONT ELEVATION /STONE STOOP - STEP - CRACKED WITH LARGE HOLE; 8610 S EXCHANGE AVE COMPLAINT FAILED View