Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR PORCH SYSTEM | NO BOLTS AT SUPPORT CONNECTIONS NO BOLTS AT STRINGER CONNECTIONS AT 3126-3128 1ST THRU 3RD FLOORS NO STRAP AT LOOKOUT TO COLUMN AT 3128 INADEQUATE AMOUNT OF BOLTS IN ALL LEDGERS THRU-OUT OBTAIN PERMITS FOR REPAIRS | 3126 N SPAULDING AVE | PERIODIC | PASSED | View |
REPAIR WINDOW SILLS | STONE SILLS HAVE OPEN MORTAR JOINTS AT 3126-28 DOUBLE WINDOW SILLS. | 3126 N SPAULDING AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH AT 3126 2ND TO 3RD FLOOR; STAIRS MISSING BALUSTERS, 4X6 COLUMN AT STAIRS IS BOWED OUTWARD. RAILS AT 3RD FLOOR DEFLECT UNDER PRESSURE. SUBMIT PLANS AND OBTAIN PERMIT FOR 3126 PORCH. | 3126 N SPAULDING AVE | PERIODIC | FAILED | View |
REPAIR STOOP | STOOP AT FRONT DOOR 3126 EAST IS CRACKED AND BROKEN. | 3126 N SPAULDING AVE | PERIODIC | FAILED | View |
MAINTAIN WINDOW SASH | ROTTED WINDOW SASH AT REAR (ALLEY SIDE) OF 3128 1ST AND 2ND FLOOR. | 3126 N SPAULDING AVE | PERIODIC | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | MISSING BALUSTERS AT 3RD FLOOR, 3126 EAST. | 3126 N SPAULDING AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | SSOUTHEAST PORCH WITH SEVERAL 6X6 COLUMNS NOTCHED ON 2 SIDES AS WELL AS A NOTCH CUT INTO COLUMN IN ERROR AND THEN PLUGGED, AND THE COLUMN SPLICE IN CLOSE PROXIMITY. ALSO PLAN SHOW 2 COLUMNS BEING "EXISTING 4X6 COLUMNS" WHEN THESE 2 COLUMNS ARE 4X4. | 3126 N SPAULDING AVE | PERMIT | PASSED | View |
PARAPET | SOUTH ELEVATION / PARAPET WALL-WASHED OUT MORTAR. | 3126 N SPAULDING AVE | PERIODIC | FAILED | View |
REPAIR COPING | SOUTH ELEVATION / PARAPET WALL MISSING COPING AT CELLULAR TOWER I-BEAM SUPPORTS. | 3126 N SPAULDING AVE | PERIODIC | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | NORTH ELEVATION / SERVICE WALK-CRACKED WITH MISSING SECTIONS. | 3126 N SPAULDING AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING / NO ENTRY UNVERIFIED DETECTORS,NO ENTRY UNABLE TO VERIFY COMPLAINT OF-LOCKED DOORS,BROKEN KNOBS AND LOCKS. | 3126 N SPAULDING AVE | PERIODIC | FAILED | View |
PARAPET | SOUTH ELEVATION / PARAPET WALL-WASHED OUT MORTAR. | 3126 N SPAULDING AVE | PERIODIC | FAILED | View |
MAINTAIN WINDOW SASH | BUILDING /NORTH AND SOUTH ELEVATIONS -WINDOW SASHES , PEELING FLAKING PAINT. | 3126 N SPAULDING AVE | PERIODIC | FAILED | View |
REPAIR COPING | SOUTH ELEVATION / PARAPET WALL MISSING COPING AT CELLULAR TOWER I-BEAM SUPPORTS. | 3126 N SPAULDING AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR DOOR | 3128 N /FRONT DOOR -BULLET HOLE IN GLASS PANEL. | 3126 N SPAULDING AVE | PERIODIC | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | NORTH ELEVATION / SERVICE WALK-CRACKED WITH MISSING SECTIONS. | 3126 N SPAULDING AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING / NO ENTRY UNVERIFIED DETECTORS,NO ENTRY UNABLE TO VERIFY COMPLAINT OF-LOCKED DOORS,BROKEN KNOBS AND LOCKS. | 3126 N SPAULDING AVE | PERIODIC | FAILED | View |
ARRANGE FOR REINSPECTION REGAR | BUILDING /NO RESPONSE, NO ENTRY TO VERIFY DETECTORS AND COMPLAINT OF ROOF LEAK 3126 N APT 3E. | 3126 N SPAULDING AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY | 3126 N SPAULDING AVE | PERIODIC | PASSED | View |