The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
STOP/REMOVE NUISANCE | SR#07-00521207 REAR YARD: LARGE AMOUNTS OF JUNK-MATTRESSES, AUTO BODY PARTS | 1819 N KEYSTONE AVE | COMPLAINT | PASSED | View |
REPAIR EXTERIOR STAIR | WEST STAIRS TO 1: LOOSE RAILINGS | 1819 N KEYSTONE AVE | COMPLAINT | PASSED | View |
CARB MONOX DETECT IN RESID | BASEMENT, 1ST, 2ND FLOORS | 1819 N KEYSTONE AVE | COMPLAINT | PASSED | View |
REPAIR ROOF | REAR PORCH: 2X4 RAFTERS WITH EXCESSIVE DEFLECTION-PLANS AND PERMITS REQUIRED FOR REPAIRS | 1819 N KEYSTONE AVE | COMPLAINT | PASSED | View |
WORK NOT ALLOWED | REMOVE ALL PARTITIONS AND FIXTURES (INCLUDING PLUMBING AND ELECTRIC) INSTALLED IN THE BASEMENT WITHOUT A PERMIT | 1819 N KEYSTONE AVE | COMPLAINT | PASSED | View |
EGRESS -BASEMENT | BASEMENT UNIT: ONLY 1 SOURCE OF EGRESS-THROUGH LAUNDRY ROOM AT EAST | 1819 N KEYSTONE AVE | COMPLAINT | PASSED | View |
SEPARATION OF DWELLING ADEQUAT | BASEMENT UNIT-1/2" DRYWALL-NOT 1 HOUR FIRE RATED | 1819 N KEYSTONE AVE | COMPLAINT | PASSED | View |
HEATING PLANT SEPARATION | BASEMENT: FURNACE ENCLOSURE-ONLY I SIDE FINISHED WITH 1/2" DRYWALL-NO 1 HOUR FIRE RATED | 1819 N KEYSTONE AVE | COMPLAINT | PASSED | View |
BASEMENT, NORTH CENTER BEDROOM: 7'4" X9'=66 SQUARE FEET | 1819 N KEYSTONE AVE | COMPLAINT | PASSED | View | |
INTERIOR FINISH FIRERESISTANCE | 1ST FLOOR: WOOD PANELING IN LIVING/DINING AREAS | 1819 N KEYSTONE AVE | COMPLAINT | PASSED | View |
EXIT THROUGH BEDROOM/BATHROOM | 1ST FLOOR: BEDROOM IN DINING AREA | 1819 N KEYSTONE AVE | COMPLAINT | PASSED | View |
CONNECT GAS APPLIANCE TO VENT | 2ND FLOOR: WALL MOUNTED SPACE HEATER-NO VENT-DANGEROUS AND HAZARDOUS | 1819 N KEYSTONE AVE | COMPLAINT | PASSED | View |
WORKING ON STOP WORK ORDER | REAR PORCH: IN PROCESS OF ENCLOSING REAR PORCH WITH 1/2" O.S.B. PLYWOOD WITHOUT PROPER PERMITS OR PLANS-NOT FIRE RATED | 1819 N KEYSTONE AVE | COMPLAINT | PASSED | View |
REPAIR PORCH SYSTEM | REAR PORCH: 2X8 JOISTS SPANNING 11'-5" AT 20" ON CENTER, JOISTS AT LANDINGS ARE MISSING JOIST HANGERS, 6X6 AND 2X8 BEAMS SPANNING 6'-6", 2X8 BEAMS SPANNING 10'-3" SUPPORTING LANDINGS, ROTTED BEAMS AT ATTIC AT NORTH AND SOUTH, GAPS AT BEAM TO COLUMN CONNECTIONS, 39" GUARDS, 9 1/4" TREADS, NO BOLTS AT STAIR STRINGER CONNECTIONS; PLANS AND PERMITS REQUIRED FOR REPAIRS TO REAR PORCH | 1819 N KEYSTONE AVE | COMPLAINT | PASSED | View |
NO CLOSET/STORAGE UNDER STAIR | JUNK , DEBRIS PILED UNDER REAR PORCH , FIRE HAZARD , RAT HARBORAGE . | 1819 N KEYSTONE AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING NO OWNER ID SIGN POSTED. | 1819 N KEYSTONE AVE | COMPLAINT | CLOSED | View |
REPAIR PORCH SYSTEM | WEST ELEVATION CONCRETE PORCH GRADE TO 1ST FLOOR,METAL HAND RAIL,LOOSE AND PULLING, ONLY 32 INCHES HIGH. | 1819 N KEYSTONE AVE | COMPLAINT | CLOSED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING/NO RESPONSE-UNVERIFIED DETECTORS,NO ENTRY,UNABLE TO VERIFY COMPLAINT OF BASEMENT APARTMENT,ONLY ONE EXIT. | 1819 N KEYSTONE AVE | COMPLAINT | CLOSED | View |
STOP/REMOVE NUISANCE | NORTH AND SOUTH ELEVATIONS , LOOSE , HANGING PHONE AND CABLE LINES , ENTANGLEMENT HAZARD .NORTH SIDE YARD OF REAR GARAGE , JUNK , DEBRIS , HIGH WEEDS , RAT HARBORAGE . | 1819 N KEYSTONE AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | REAR PORCH DOOR AT GRADE , ROTTED , BENT AND BROKEN , BUILDING NOT SECURE . | 1819 N KEYSTONE AVE | COMPLAINT | FAILED | View |
SERVICE DROP OUT OF REACH | INCOMING POWER SERVICE CABLES WITHIN REACH OFF SECOND FLOOR DECK , HAZARD TO TENANTS AND OCCUPANTS . | 1819 N KEYSTONE AVE | COMPLAINT | FAILED | View |
INSPECT CONSTRUCTION WORK | PERMIT # 100603630 ISSUED 7/7/2015 FOR GARAGE , NO PERMIT AVAILABLE FOR INSPECTORS REVIEW AT TIME OF INSPECTION . | 1819 N KEYSTONE AVE | COMPLAINT | FAILED | View |
NO GASOLINE(LPG) STORAGE | GASOLINE LAWNMOWER STORED UNDER WOOD PORCH AT BASEMENT , FIRE AND SAFETY HAZARD . | 1819 N KEYSTONE AVE | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | REAR THREE STORY WOOD PORCH , (PORCH HAS ATTIC STAIR AND DECK ) PREVIOUS REPAIRS POOR AND SUBSTANDARD . PORCH ROOF AT ATTIC ,RAFTERS AND DECKING REPLACED WITHOUT PERMIT . UNKNOWN FOUNDATION STATUS . UPRIGHTS DOUBLE NOTCHED WITH CONNECTIONS ONLY NAILED . BEAMS UNDERSIZED , PULLING OUT AT FIRECUT AND ONLY NAILED . FLOOR JOIST SCABBED , UNDERSIZED AND OVERSPANNED . DECKING UNDERSIZED . NO STAIR HEADER SUPPORT WITH TREADS ONLY NINE INCHES WIDE . ALL GUARDRAILS AND HANDRAILS UNDERSIZED AND ONLY NAILED WITH LOOSE , TWISTED PICKETS . PLANS AND PERMITS REQUIRED . | 1819 N KEYSTONE AVE | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | NORTH AND SOUTH ELEVATIONS , LOOSE , HANGING PHONE AND CABLE LINES , ENTANGLEMENT HAZARD .NORTH SIDE YARD OF REAR GARAGE , JUNK , DEBRIS , HIGH WEEDS , RAT HARBORAGE . | 1819 N KEYSTONE AVE | COMPLAINT | PASSED | View |
NO CLOSET/STORAGE UNDER STAIR | JUNK , DEBRIS PILED UNDER REAR PORCH , FIRE HAZARD , RAT HARBORAGE . | 1819 N KEYSTONE AVE | COMPLAINT | PASSED | View |
POST OWNER/MANAGERS NAME/# | BUILDING - NO OWNER'S I.D. SIGN POSTED . | 1819 N KEYSTONE AVE | COMPLAINT | PASSED | View |
INSPECT CONSTRUCTION WORK | PERMIT # 100603630 ISSUED 7/7/2015 FOR GARAGE , NO PERMIT AVAILABLE FOR INSPECTORS REVIEW AT TIME OF INSPECTION . | 1819 N KEYSTONE AVE | COMPLAINT | PASSED | View |
REPLACE D&H PORCH | REAR THREE STORY WOOD PORCH , (PORCH HAS ATTIC STAIR AND DECK ) PREVIOUS REPAIRS POOR AND SUBSTANDARD . PORCH ROOF AT ATTIC ,RAFTERS AND DECKING REPLACED WITHOUT PERMIT . UNKNOWN FOUNDATION STATUS . UPRIGHTS DOUBLE NOTCHED WITH CONNECTIONS ONLY NAILED . BEAMS UNDERSIZED , PULLING OUT AT FIRECUT AND ONLY NAILED . FLOOR JOIST SCABBED , UNDERSIZED AND OVERSPANNED . DECKING UNDERSIZED . NO STAIR HEADER SUPPORT WITH TREADS ONLY NINE INCHES WIDE . ALL GUARDRAILS AND HANDRAILS UNDERSIZED AND ONLY NAILED WITH LOOSE , TWISTED PICKETS . PLANS AND PERMITS REQUIRED . | 1819 N KEYSTONE AVE | COMPLAINT | PASSED | View |
REPAIR EXTERIOR DOOR | REAR PORCH DOOR AT GRADE , ROTTED , BENT AND BROKEN , BUILDING NOT SECURE . | 1819 N KEYSTONE AVE | COMPLAINT | PASSED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING - UNVERIFIED CONDITIONS , DETECTORS AND OCCUPANCY OF BASEMENT AND ATTIC . | 1819 N KEYSTONE AVE | COMPLAINT | PASSED | View |
INTERIOR FINISH FIRERESISTANCE | REAR WOOD PORCH AT GRADE , EXPOSED WOOD FRAMING AND PLYWOOD SHEETING AT PORCH ENCLOSED PORTION . | 1819 N KEYSTONE AVE | COMPLAINT | PASSED | View |
SERVICE DROP OUT OF REACH | INCOMING POWER SERVICE CABLES WITHIN REACH OFF SECOND FLOOR DECK , HAZARD TO TENANTS AND OCCUPANTS . | 1819 N KEYSTONE AVE | COMPLAINT | PASSED | View |
NO GASOLINE(LPG) STORAGE | GASOLINE LAWNMOWER STORED UNDER WOOD PORCH AT BASEMENT , FIRE AND SAFETY HAZARD . | 1819 N KEYSTONE AVE | COMPLAINT | PASSED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING - UNVERIFIED CONDITIONS , DETECTORS AND OCCUPANCY OF BASEMENT AND ATTIC . | 1819 N KEYSTONE AVE | COMPLAINT | FAILED | View |