Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-26 @ 1:43 AM
PIN: 13344150140000
Property Address: 1819 N KEYSTONE AVE
City - Zip: CHICAGO - 60639
2023 Property Class: 211
2023 Township: 71 - Jefferson
2023 Neighborhood: 71520
2023 Tax District: 71163
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 35 Violations
Violation Inspector Comments Address Category Status View
STOP/REMOVE NUISANCE SR#07-00521207 REAR YARD: LARGE AMOUNTS OF JUNK-MATTRESSES, AUTO BODY PARTS 1819 N KEYSTONE AVE COMPLAINT PASSED View
REPAIR EXTERIOR STAIR WEST STAIRS TO 1: LOOSE RAILINGS 1819 N KEYSTONE AVE COMPLAINT PASSED View
CARB MONOX DETECT IN RESID BASEMENT, 1ST, 2ND FLOORS 1819 N KEYSTONE AVE COMPLAINT PASSED View
REPAIR ROOF REAR PORCH: 2X4 RAFTERS WITH EXCESSIVE DEFLECTION-PLANS AND PERMITS REQUIRED FOR REPAIRS 1819 N KEYSTONE AVE COMPLAINT PASSED View
WORK NOT ALLOWED REMOVE ALL PARTITIONS AND FIXTURES (INCLUDING PLUMBING AND ELECTRIC) INSTALLED IN THE BASEMENT WITHOUT A PERMIT 1819 N KEYSTONE AVE COMPLAINT PASSED View
EGRESS -BASEMENT BASEMENT UNIT: ONLY 1 SOURCE OF EGRESS-THROUGH LAUNDRY ROOM AT EAST 1819 N KEYSTONE AVE COMPLAINT PASSED View
SEPARATION OF DWELLING ADEQUAT BASEMENT UNIT-1/2" DRYWALL-NOT 1 HOUR FIRE RATED 1819 N KEYSTONE AVE COMPLAINT PASSED View
HEATING PLANT SEPARATION BASEMENT: FURNACE ENCLOSURE-ONLY I SIDE FINISHED WITH 1/2" DRYWALL-NO 1 HOUR FIRE RATED 1819 N KEYSTONE AVE COMPLAINT PASSED View
BASEMENT, NORTH CENTER BEDROOM: 7'4" X9'=66 SQUARE FEET 1819 N KEYSTONE AVE COMPLAINT PASSED View
INTERIOR FINISH FIRERESISTANCE 1ST FLOOR: WOOD PANELING IN LIVING/DINING AREAS 1819 N KEYSTONE AVE COMPLAINT PASSED View
EXIT THROUGH BEDROOM/BATHROOM 1ST FLOOR: BEDROOM IN DINING AREA 1819 N KEYSTONE AVE COMPLAINT PASSED View
CONNECT GAS APPLIANCE TO VENT 2ND FLOOR: WALL MOUNTED SPACE HEATER-NO VENT-DANGEROUS AND HAZARDOUS 1819 N KEYSTONE AVE COMPLAINT PASSED View
WORKING ON STOP WORK ORDER REAR PORCH: IN PROCESS OF ENCLOSING REAR PORCH WITH 1/2" O.S.B. PLYWOOD WITHOUT PROPER PERMITS OR PLANS-NOT FIRE RATED 1819 N KEYSTONE AVE COMPLAINT PASSED View
REPAIR PORCH SYSTEM REAR PORCH: 2X8 JOISTS SPANNING 11'-5" AT 20" ON CENTER, JOISTS AT LANDINGS ARE MISSING JOIST HANGERS, 6X6 AND 2X8 BEAMS SPANNING 6'-6", 2X8 BEAMS SPANNING 10'-3" SUPPORTING LANDINGS, ROTTED BEAMS AT ATTIC AT NORTH AND SOUTH, GAPS AT BEAM TO COLUMN CONNECTIONS, 39" GUARDS, 9 1/4" TREADS, NO BOLTS AT STAIR STRINGER CONNECTIONS; PLANS AND PERMITS REQUIRED FOR REPAIRS TO REAR PORCH 1819 N KEYSTONE AVE COMPLAINT PASSED View
NO CLOSET/STORAGE UNDER STAIR JUNK , DEBRIS PILED UNDER REAR PORCH , FIRE HAZARD , RAT HARBORAGE . 1819 N KEYSTONE AVE COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# BUILDING NO OWNER ID SIGN POSTED. 1819 N KEYSTONE AVE COMPLAINT CLOSED View
REPAIR PORCH SYSTEM WEST ELEVATION CONCRETE PORCH GRADE TO 1ST FLOOR,METAL HAND RAIL,LOOSE AND PULLING, ONLY 32 INCHES HIGH. 1819 N KEYSTONE AVE COMPLAINT CLOSED View
ARRANGE PREMISE INSPECTION INTERIOR OF BUILDING/NO RESPONSE-UNVERIFIED DETECTORS,NO ENTRY,UNABLE TO VERIFY COMPLAINT OF BASEMENT APARTMENT,ONLY ONE EXIT. 1819 N KEYSTONE AVE COMPLAINT CLOSED View
STOP/REMOVE NUISANCE NORTH AND SOUTH ELEVATIONS , LOOSE , HANGING PHONE AND CABLE LINES , ENTANGLEMENT HAZARD .NORTH SIDE YARD OF REAR GARAGE , JUNK , DEBRIS , HIGH WEEDS , RAT HARBORAGE . 1819 N KEYSTONE AVE COMPLAINT FAILED View
REPAIR EXTERIOR DOOR REAR PORCH DOOR AT GRADE , ROTTED , BENT AND BROKEN , BUILDING NOT SECURE . 1819 N KEYSTONE AVE COMPLAINT FAILED View
SERVICE DROP OUT OF REACH INCOMING POWER SERVICE CABLES WITHIN REACH OFF SECOND FLOOR DECK , HAZARD TO TENANTS AND OCCUPANTS . 1819 N KEYSTONE AVE COMPLAINT FAILED View
INSPECT CONSTRUCTION WORK PERMIT # 100603630 ISSUED 7/7/2015 FOR GARAGE , NO PERMIT AVAILABLE FOR INSPECTORS REVIEW AT TIME OF INSPECTION . 1819 N KEYSTONE AVE COMPLAINT FAILED View
NO GASOLINE(LPG) STORAGE GASOLINE LAWNMOWER STORED UNDER WOOD PORCH AT BASEMENT , FIRE AND SAFETY HAZARD . 1819 N KEYSTONE AVE COMPLAINT FAILED View
REPLACE D&H PORCH REAR THREE STORY WOOD PORCH , (PORCH HAS ATTIC STAIR AND DECK ) PREVIOUS REPAIRS POOR AND SUBSTANDARD . PORCH ROOF AT ATTIC ,RAFTERS AND DECKING REPLACED WITHOUT PERMIT . UNKNOWN FOUNDATION STATUS . UPRIGHTS DOUBLE NOTCHED WITH CONNECTIONS ONLY NAILED . BEAMS UNDERSIZED , PULLING OUT AT FIRECUT AND ONLY NAILED . FLOOR JOIST SCABBED , UNDERSIZED AND OVERSPANNED . DECKING UNDERSIZED . NO STAIR HEADER SUPPORT WITH TREADS ONLY NINE INCHES WIDE . ALL GUARDRAILS AND HANDRAILS UNDERSIZED AND ONLY NAILED WITH LOOSE , TWISTED PICKETS . PLANS AND PERMITS REQUIRED . 1819 N KEYSTONE AVE COMPLAINT FAILED View
STOP/REMOVE NUISANCE NORTH AND SOUTH ELEVATIONS , LOOSE , HANGING PHONE AND CABLE LINES , ENTANGLEMENT HAZARD .NORTH SIDE YARD OF REAR GARAGE , JUNK , DEBRIS , HIGH WEEDS , RAT HARBORAGE . 1819 N KEYSTONE AVE COMPLAINT PASSED View
NO CLOSET/STORAGE UNDER STAIR JUNK , DEBRIS PILED UNDER REAR PORCH , FIRE HAZARD , RAT HARBORAGE . 1819 N KEYSTONE AVE COMPLAINT PASSED View
POST OWNER/MANAGERS NAME/# BUILDING - NO OWNER'S I.D. SIGN POSTED . 1819 N KEYSTONE AVE COMPLAINT PASSED View
INSPECT CONSTRUCTION WORK PERMIT # 100603630 ISSUED 7/7/2015 FOR GARAGE , NO PERMIT AVAILABLE FOR INSPECTORS REVIEW AT TIME OF INSPECTION . 1819 N KEYSTONE AVE COMPLAINT PASSED View
REPLACE D&H PORCH REAR THREE STORY WOOD PORCH , (PORCH HAS ATTIC STAIR AND DECK ) PREVIOUS REPAIRS POOR AND SUBSTANDARD . PORCH ROOF AT ATTIC ,RAFTERS AND DECKING REPLACED WITHOUT PERMIT . UNKNOWN FOUNDATION STATUS . UPRIGHTS DOUBLE NOTCHED WITH CONNECTIONS ONLY NAILED . BEAMS UNDERSIZED , PULLING OUT AT FIRECUT AND ONLY NAILED . FLOOR JOIST SCABBED , UNDERSIZED AND OVERSPANNED . DECKING UNDERSIZED . NO STAIR HEADER SUPPORT WITH TREADS ONLY NINE INCHES WIDE . ALL GUARDRAILS AND HANDRAILS UNDERSIZED AND ONLY NAILED WITH LOOSE , TWISTED PICKETS . PLANS AND PERMITS REQUIRED . 1819 N KEYSTONE AVE COMPLAINT PASSED View
REPAIR EXTERIOR DOOR REAR PORCH DOOR AT GRADE , ROTTED , BENT AND BROKEN , BUILDING NOT SECURE . 1819 N KEYSTONE AVE COMPLAINT PASSED View
ARRANGE PREMISE INSPECTION INTERIOR OF BUILDING - UNVERIFIED CONDITIONS , DETECTORS AND OCCUPANCY OF BASEMENT AND ATTIC . 1819 N KEYSTONE AVE COMPLAINT PASSED View
INTERIOR FINISH FIRERESISTANCE REAR WOOD PORCH AT GRADE , EXPOSED WOOD FRAMING AND PLYWOOD SHEETING AT PORCH ENCLOSED PORTION . 1819 N KEYSTONE AVE COMPLAINT PASSED View
SERVICE DROP OUT OF REACH INCOMING POWER SERVICE CABLES WITHIN REACH OFF SECOND FLOOR DECK , HAZARD TO TENANTS AND OCCUPANTS . 1819 N KEYSTONE AVE COMPLAINT PASSED View
NO GASOLINE(LPG) STORAGE GASOLINE LAWNMOWER STORED UNDER WOOD PORCH AT BASEMENT , FIRE AND SAFETY HAZARD . 1819 N KEYSTONE AVE COMPLAINT PASSED View
ARRANGE PREMISE INSPECTION INTERIOR OF BUILDING - UNVERIFIED CONDITIONS , DETECTORS AND OCCUPANCY OF BASEMENT AND ATTIC . 1819 N KEYSTONE AVE COMPLAINT FAILED View