REPAIR/REBUILD GARAGE OR SHED | BRICK GARAGE WITH THE FOLLOWING DEFECTS.1.-NORTH AND SOUTH ELEVATIONS ARE BOWED OUT AND WITH SEVERE MORTAR JOINT EROSION AND SPALLED BRICKS.2.-EAST ELEVATION IS SINKING DUE TO THE UNDER GROUND EROSION CAUSED BY THE BUILDINGS DOWNSPOUT. SEE STEP CRACKS AND OPEN JOINTS.3.-ROOF IS DETIRIORATED AND PEELING OFF THE PARAPETS, AS SEEN FROM ATOP OF EXTERIOR STAIR SYSTEM.THE FRONT ROOF EAVE IS SEVERELY ROTTED.4.-WEST VEHICLE ENTRY DOOR FRAME COMPONENTS SEVERELY ROTTED. SOUTH SERVICE ENTRY DOOR AND FRAME SEVERELY ROTTED, ASSEMBLIES BEYOND REPAIRS.5.-SEVERELY RUSTED, CRUSHED GUTTER AND DOWNSPOUT.6.-EAST WINDOW COMPONENTS SEVERELY ROTTED, BROKEN PANES.7.-MASON'S PERMIT REQUIRED. | 7730 S EAST END AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH GRADE TO 3RD FLOOR 3RD FLOOR TOP GUARD RAIL CRACKED2ND TO 3RD FLOOR STRINGER CRACKED.2ND FLOOR GUARD RAIL LOOSE. | 7730 S EAST END AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | THREE STORY OPEN WOOD STAIR WITH ROOF AND BASEMENT ACCESS -(1) UNTREATED WOOD IS BEGINNING TO SHOW WEAR AND EXHIBIT MODERATE STAGES OF ROTT WITH SOME MEMBERS WARPED AND/OR SPLIT(2) STAIR STRINGERS HAVE ONLY ONE BOLT AT THE TOP AND BOTTOM CONNECTIONS TO POST AND COLUMNS(3) MANY CLIPS AND BOLTS EXHIBIT VARYING DEGREES OF RUST(4) REPAIR PERMIT REQUIRED - A PASSED PERMIT INSPECTION WITH THE DEPARTMENT OF BUILDINGS IS REQUIRED TO COMPLY THE VIOLATION | 7730 S EAST END AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR STAIR | WEST EXTERIOR STAIR SYSTEM WITH THE FOLLOWING DEFECTS.1.-UNKNOWN FOOTING DEPTH, SEE CONCRETE WRAPED AROUND THE BASE OF COLUMNS.2.-COLUMNS ARE DRY ROTTED, BOWED. A.- LAP JOINTS AT 15'' IN LENGHT AND WITH UNDERSIZED BOLTS. SEE RUST.3.-EXTERIOR JOISTS TOE NAILED AND IMBEDDED IN COLUMNS. A.- MISSING HANGERS WHERE REQUIRED.4.-STRINGERS TOE NAILED AT ENDS, WALL SECTIONS WITH CUT NAILS. A.- BOTTOM FLIGHT OF STAIRS NOT ANCHORED AT GRADE, EASY TO SWAY. B.-STAIR TREADS ARE DRY ROTTED AND SPLIT AT MULTIPLE LOCATIONS.5.-GUARD AND HAND RAILS WITH TOE NAILED ANCHOR ENDS, SEE RUSTED NAILS. A.-PICKETS NAILED FROM TOP OF HAND RAILING. SEE LOOSE AND WEAK PICKETS. B.-GRADE TO BASEMENT WITH OUT A HAND RAIL. C.-MISSING GUARD RAIL PICKETS AT MID 2ND AND 3RD FLOOR LANDING.6.-4X4 GUARD AND HAND RAIL TRANSSITION POST TOE NAILED, EASY TO MOVE/DEFLECT.7.-ROOF'S SCUTTLE HATCH COVER MISSING.8.-PLANS AND PERMITS REQUIRED. | 7730 S EAST END AVE | PERIODIC | FAILED | View |
PARAPET | NORTH AND SOUTH PARAPETS WITH ERODED MORTAR JOINTS. A.-NORTHWEST CORNER WITH LOOSE BRICKS. | 7730 S EAST END AVE | PERIODIC | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | REAR YARD WITH SEVERELY BROKEN AND CONCAVED SECTIONS. | 7730 S EAST END AVE | PERIODIC | FAILED | View |
REPAIR GUTTER & DOWNSPOUT | WEST.-SEVERELY RUSTED, SEE HOLES, GUTTER AND DOWNSPOUT.A.-SEWER CONNECTION UNDER SERVICE WALK BROKEN CAUSING SEVERE UNDER GROUND EROSION THUS AFFECTING SERVICE WALKS AND GARAGE. | 7730 S EAST END AVE | PERIODIC | FAILED | View |
REPAIR SCREENS | ALL ELEVATIONS.-MISSING OR TORN WINDOW SCREENS. | 7730 S EAST END AVE | PERIODIC | FAILED | View |
REGISTER/SECURE/INSURE-VACANT | BUILDING IS NOW VACANT AND SECURE, NO REGISTRATION AS SUCH IN ARCHIVES. | 7730 S EAST END AVE | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | MISSING INFORMATION PLACARD. | 7730 S EAST END AVE | PERIODIC | FAILED | View |
PRV CAST IRON COVER FOR BASIN | REAR YARD CATCH BASIN COVER MISSING. | 7730 S EAST END AVE | PERIODIC | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | SOUTH ELEVATION - 1ST FLOOR WINDOW BOARD UP. | 7730 S EAST END AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | REAR 1ST FLOOR STEP CRACKED.REAR 3RD FLOOR SPALLING BRICK. | 7730 S EAST END AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING - NO RESPONSE UNVERIFIED DETECTORS AND CONDITIONS | 7730 S EAST END AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH GRADE TO 3RD FLOOR 3RD FLOOR TOP GUARD RAIL CRACKED2ND TO 3RD FLOOR STRINGER CRACKED.2ND FLOOR GUARD RAIL LOOSE. | 7730 S EAST END AVE | PERIODIC | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | SOUTH ELEVATION - 1ST FLOOR WINDOW BOARD UP. | 7730 S EAST END AVE | PERIODIC | FAILED | View |
REPAIR WINDOW SILLS | EAST ELEVATION / SILLS - WASHED OUT MORTAR. | 7730 S EAST END AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR O BUILDING - NO RESPONSE, UNVERIFIED DETECTORS AND CONDITIONS. | 7730 S EAST END AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | WEST ELEVATION / 3 STORY WOOD PORCH / STRINGERS - WORN AND CRACKING. STEEL HARDWARE - RUSTED AND DETERIORATED. | 7730 S EAST END AVE | COMPLAINT | FAILED | View |
UNAPPROVED CORDS | REAR 1ST FLOOR - RUNNING 2 EXTENSION CORDS FROM BASEMENT INTO APT. DANGEROUS AND HAZARDOUS PER SECTION CODE : REMOVE UNAPPROVED FLEXIBLE CORD. (14E-4-400.12) | 7730 S EAST END AVE | COMPLAINT | FAILED | View |