Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
INSECTS | BUILDING - BED BUG INFESTATION THROUGH OUT. PROPERTY MUST BE EFFECTIVELY TREATED TO EXTERMINATE BED BUGS THROUGHOUT, BY EMPLOYING AN EXSPERIENCED EXTERMINATOR INABATEMENT OF BED BUG INFESTATION. BUILDING DEPARTMENT WILL NOT CONSIDER THIS VILOALTION COMPLIED WITHOUT PROOF OF SAID EXTERMINATION. | 6120 N WASHTENAW AVE | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | BUILDING INTERIOR EXCESSIVE ANT INFESTATION, POSSIBLE DUE TO TREE BRANCHES AGAINST EXTERIOR FRONT OF BUILDING. | 6120 N WASHTENAW AVE | COMPLAINT | FAILED | View |
PARAPET | PARAPET WALL SOUTH AND NORTH ELEVATIONS SPALLING BRICK AND ERODING MORTAR. | 6120 N WASHTENAW AVE | COMPLAINT | FAILED | View |
CHIMNEY | CHIMNSY- SPALLING BRICK AND ERODING MORTAR. | 6120 N WASHTENAW AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | FRONT DOOR DRAGS ON FLOOR AND GETS STUCK. | 6120 N WASHTENAW AVE | COMPLAINT | FAILED | View |
INSECTS | UNIT 1 AND 2- BED BUGS. PROPERTY MSUT BE EFFECTIVELY TREATED TO EXTERMINATE BED BUGS THROUGHOUT, BY EMPLOYING AN EXPERIENCED EXTERMINATOR IN ABATEMENT OF BED BUG INFESTATION. BUILDING DEPARTMENT WILL NOT CONSIDER THIS VIOLATION COMPLIED WITHOUT PROOF OF SAID EXTERMINATION. | 6120 N WASHTENAW AVE | COMPLAINT | FAILED | View |
REMV OBSTR FROM DRAINAGE SYSTM | UNIT 2 WITH CLOGGED BATH TUB AND KITCHEN SINK. | 6120 N WASHTENAW AVE | COMPLAINT | FAILED | View |
REPAIR/REPLACE SMOKE DETECTORS | SMOKE DETECTOR NOT OPERATING UNIT 2. | 6120 N WASHTENAW AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY BASEMENT. | 6120 N WASHTENAW AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | GANG WAY WALL WITH SIGNIFICANT FRACTURES. | 6120 N WASHTENAW AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH- 39'' GUARD RAILS. STRINGERS, POSTS, RAILS, BEAM AND COLUMNS, ALL ANCHORED WITH NAILS ONLY. LANDING BEAM 2X8 SPANS 9'. SINGLE STRINGER HEADER 2X8 SPANS 6' 8''. RAILING COMPONENTS SEPARATING. TWISTING COLUMNS WITH GAPS AT SPLICES. MISSING PICKETS. RAILS SPAN UP TO 6' 8'' WITH NO CENTRAL SUPPORT, DEFLECTING RAILS. OBTAIN PLAN AND PERMIT FOR PORCH REPAIR. | 6120 N WASHTENAW AVE | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | REAR SERVICE WALKS- FRACTURES. | 6120 N WASHTENAW AVE | COMPLAINT | FAILED | View |
REPAIR/REBUILD GARAGE OR SHED | GARAGE- SEVERE MASONRY DAMAGE, FRACTURES AND SHIFTING BRICK AT NORTH WEST CORNER. PARAPET WALL ERODING MORTAR AND SPALLING BRICK. OVER HEAD DOOR FRAMES ROTTING AND BROKEN. SERVICE DOOR WITH ROTTING CASING. PERMIT REQUIRED FOR REPAIRS. | 6120 N WASHTENAW AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING - NO OWNER'S ID SIGN POSTED. | 6120 N WASHTENAW AVE | COMPLAINT | PASSED | View |
PARAPET | NORTH AND SOUTH ELEVATION PARAPET WALLS - SPALLING BRICKS AND WASHED OUT MORTAR. | 6120 N WASHTENAW AVE | COMPLAINT | PASSED | View |
REPAIR ROOF | ROOF LEAKING THROUGHOUT 3RD FLOOR UNIT. | 6120 N WASHTENAW AVE | COMPLAINT | PASSED | View |
REPAIR/REBUILD GARAGE OR SHED | GARAGE - OVERHEAD DOOR BROKEN AND OFF TRACK, MISSING BRICKS AT SERVICE DOOR. SERVICE DOOR AND FRAME ARE LOOSE. | 6120 N WASHTENAW AVE | COMPLAINT | PASSED | View |
SERVICE WALK, PASSAGE, AREAWAY | REAR SERVICE WALK - FRACTURED AND BUCKLED CONCRETE. | 6120 N WASHTENAW AVE | COMPLAINT | PASSED | View |
REPAIR PORCH SYSTEM | REAR 3 STORY WOOD PORCH -6X6 COLUMNS SET ON UNDERSIZED CONCRETE BLOCKS SET IN SLAB, FOUNDATION STATUS UNKNOWN.6X6 COLUMNS ARE DOUBLE NOTCHED AT BEAM TO COLUMN CONNECTION AREA,2X8 BEAMS NAILED TO COLUMNS.STRINGERS WRAPPED UNDER HEADERS AND NAILED TO JOIST.LEDGER BEAMS NAILED TO BUILDING.GUARDRAILS NAILED TO BUILDING AND MISSING INTERMEDIATE SUPPORT POST.PLANS AND PERMIT REQUIRED. | 6120 N WASHTENAW AVE | COMPLAINT | PASSED | View |
REPAIR INTERIOR WALLS/CEILING | 1ST FLOOR APARTMENT - FRACTURES IN PLASTER THOUGHOUT.2ND FLOOR, 3RD FLOOR APARTMENTS AND FRONT STAIRWAY - SECTIONS OF MISSING PLASTER, FRACTURES THOUGHOUT 3RD FLOOR APARTMENT CEILING HAS COLLAPSED.FRONT STAIRWAY - FRACTURES THROUGHOUT, CEILING COLLAPSED. EAST WALL OF STAIRWAY HAS SHIFTED AND LEANING, SEVERAL INCHES OUT OF PLUMB. | 6120 N WASHTENAW AVE | COMPLAINT | PASSED | View |
SUBMIT 2 COPY STRUCTURAL RPT | BUILDING - STRUCTURAL ENGINEERS REPORT REQUIRED FOR ENTIRE BUILDING, REPORT TO ADDRESS ALL INTERIOR STRUCTURAL CONDITIONS. | 6120 N WASHTENAW AVE | COMPLAINT | PASSED | View |
REPAIR FLOOR | FRONT LIVING ROOM FLOORS ALL LEVELS - FRONT FOYER FLOOR IS BUCKLED, FRONT LIVINGROOM FLOORS OF ALL UNITS HAVE SUNK SEVERAL INCHES. | 6120 N WASHTENAW AVE | COMPLAINT | PASSED | View |
SAFE WORKING CONDITIONS | BASEMENT - BOILER FOR ENTIRE BUILDING IS NOT WORKING, PARTIALLY DISMANTLED. | 6120 N WASHTENAW AVE | COMPLAINT | PASSED | View |
UNAPPROVED HEATING DEVICE | 1ST FLOOR TENANTS USING ELECTRIC HEATERS THROUGHOUT UNIT. | 6120 N WASHTENAW AVE | COMPLAINT | PASSED | View |
WORK NOT ALLOWED | BASEMENT - REMOVE ALL PARTITIONS AND FIXTURES (INCLUDING ALL ELECTRICAL AND PLUMBING) INSTALLED IN THE BASEMENT WITHOUT A PERMIT. | 6120 N WASHTENAW AVE | COMPLAINT | PASSED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO THE BASEMENT OR RESTORE THE BUILDING TO THE ORIGINAL STATE, ALSO REQUIRED TO DECONVERT BASEMENT. | 6120 N WASHTENAW AVE | COMPLAINT | PASSED | View |
REPAIR INTERIOR STAIR SYSTEM | FRONT INTERIOR STAIRWAY - STRINGERS AND GUARDRAILS ARE SEPERATING FROM SUPPORTS, LOOSE TREADS, DANGEROUS AND HAZARDOUS CONDITIONS. | 6120 N WASHTENAW AVE | COMPLAINT | PASSED | View |
SAFE WORKING CONDITIONS | BOILER NOT WORKING TO PROVIDE INSUFFICIENT HEAT ONLY 63-64 TRUTH OUT 1ST FLOOR APARTMENT (RADIATORS COLD) | 6120 N WASHTENAW AVE | COMPLAINT | FAILED | View |
ARRANGE COMPLETED PERMIT INSP. | 6120 N WASHTENAW AVE | PERMIT | PASSED | View | |
REPAIR EXTERIOR DOOR | 2ND FLOOR REAR DOOR - BROKEN AND MISSING GLASS PANES. | 6120 N WASHTENAW AVE | COMPLAINT | PASSED | View |