The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
| Violation | Inspector Comments | Address | Category | Status | View |
|---|---|---|---|---|---|
| REPAIR FENCE | FRONT / CHAIN LINK FENCE - LOOSE AND LEANING | 9351 S UNIVERSITY AVE | COMPLAINT | FAILED | View |
| EXPOSED WIRING | FRONT HOUSE 1ST FL / EXPOSE WIRES- BATHROOM CEILING AND WALLS | 9351 S UNIVERSITY AVE | COMPLAINT | FAILED | View |
| REPAIR INTERIOR WALLS/CEILING | FRONT HOUSE / 1ST FL BATHROOM - CEILING AND WALL WOOD LATH ONLY . | 9351 S UNIVERSITY AVE | COMPLAINT | FAILED | View |
| REPLACE DEFECTIVE FAUCET | FRONT HOUSE / 1ST FL BATHROOM - BATH TUB AND SINK BROKEN | 9351 S UNIVERSITY AVE | COMPLAINT | FAILED | View |
| WINDOW REPAIR FOR AIR SEEPAGE | FRONT HOUSE / FRONT AND REAR /AIRSEEPAGE - EXTERIOR DOORS.FRONT HOUSE APT 1/ SOUTH AND WEST ELEVATION /AIR SEEPAGE - WINDOWS .PER SECTION CODE (14X-3-303.13 AND 14X-12-1202.4.3.3) | 9351 S UNIVERSITY AVE | COMPLAINT | FAILED | View |
| SAFE WORKING CONDITIONS | FRONT HOUSE / FURNACE - BROKEN .PER SECTION CODE (.1, 14X-8-80414X-3-305.1, 14X-8-804.4 AND 14X-8-804.5) BHA CODES | 9351 S UNIVERSITY AVE | COMPLAINT | FAILED | View |
| REPAIR ROOF STRUCTURE | FRONT HOUSE / 1ST FL ROOF - 8X8 BEAM ROTTED AND SCAB .PERMIT REQUIRED TO REPLACE BEAM | 9351 S UNIVERSITY AVE | COMPLAINT | FAILED | View |
| INSTALL SMOKE DETECTORS | FRONT HOUSE / 1ST FL AND ATTIC / SMOKE DETECTOR - MISSING.PER SECTION CODE 14X-5-504.8,14X-5-504.8.4, 14B-9-907.2.10.1 THROUGH 14B-9-907.2.10.7, 14B-9-915.4.4, AND 14R-11-1104 | 9351 S UNIVERSITY AVE | COMPLAINT | FAILED | View |
| REPAIR CATCH BASIN | REAR YARD / CATCH BASIN - BROKEN | 9351 S UNIVERSITY AVE | COMPLAINT | FAILED | View |
| OBSTRUCTIONS IN EXIT WAY | FRONT HOUSE / FRONT EGRESS - DOES NOT OPEN FRONT HOUSE / REAR ATTIC EGRESS - DOES NOT OPEN | 9351 S UNIVERSITY AVE | COMPLAINT | FAILED | View |
| REPAIR EXTERIOR WALL | REAR YARD / EXTERIOR WALL - UNDER PORCH WASHED OUT MORTAR | 9351 S UNIVERSITY AVE | COMPLAINT | FAILED | View |
| STOP/REMOVE NUISANCE | FRONT HOUSE/ NUISANCE- REAR PORCH CAR PARTS UNDER PORCH . | 9351 S UNIVERSITY AVE | COMPLAINT | FAILED | View |
| MAINTAIN WINDOW | FRONT HOUSE / NORTH ELEVATION / WINDOW -1ST FL BOARD UP | 9351 S UNIVERSITY AVE | COMPLAINT | FAILED | View |
| PROVIDE COLD WATER TO FICTURES | FRONT HOUSE / 1ST FL BATHROOM / COLD WATER TURN OFF . PER SECTION CODE . (14X-9-905.4) BHA CODES | 9351 S UNIVERSITY AVE | COMPLAINT | FAILED | View |
| HEAT UNIT ADEQUATELY | FRONT HOUSE /1ST FL / TEMP AT 554 PM LIVING ROOM 41 AND 1ST BEDROOM 43 DEGREES.ATTIC BEDROOM 43 DEGREES . PER SECTION CODE 14X-8-802.2, 14X-8-802.2.1AND 14X-8-802.2.2) BHA CODES | 9351 S UNIVERSITY AVE | COMPLAINT | FAILED | View |
| SERVICE WALK, PASSAGE, AREAWAY | REAR YARD / SERVICE WALK - BROKEN | 9351 S UNIVERSITY AVE | COMPLAINT | FAILED | View |
| CHIMNEY CAPPING | FRONT HOUSE / CHIMNEY CAP - MISSING | 9351 S UNIVERSITY AVE | COMPLAINT | FAILED | View |
| REPAIR FLOOR | FRONT HOUSE / 1ST FL FLOORS LIVING ROOM HOLES AND KITCHEN TILE BROKEN | 9351 S UNIVERSITY AVE | COMPLAINT | FAILED | View |
| REPAIR PORCH SYSTEM | FRONT HOUSE / REAR / EXTERIOR PORCH- GRADE 2ND FL .4X4 POST BY STRINGER ERECTED ON DIRT. LEDGER BOARD NAILED TO WALL .BEAM TOE NAILED TO WALL .JOIST NAILED TO HEADERS. 1ST RISER 12 INCH HIGH.GUARDRAILS AND STRINGERS NAILED ONLY TO COLUMNS,HEADERS AND WALL.PICKETS LOOSE AND GUARDRAILS OVER SPAN .PLANS AND PERMIT REQUIRED TO REPAIR REAR PORCH .FRONT HOUSE / FRONT PORCH - GRADE TO 1ST FL LEDGER BOARD NAILED TO WALL BEAM NAILED TO WALL JOIST NAILE TO HEADERS. JOIST OVER 24 ON CENTER JOIST 1END HANGING DOWN FROM DECKING 2FT JOIST AND DECKING ROTTED .LANDING NOT STABLE AND DECKING LEFTING UP .PICKETS LOOSE .CEMENT STEP BROKEN GUARDRAIL AND STRINGERS NAILED ONLY TO GUARDRAILS AND STRINGERS .PERMIT REQUIRED TO REPAIR FRONT PORCH | 9351 S UNIVERSITY AVE | COMPLAINT | FAILED | View |
| ILLUMINATE EXIT AREAS | FRONT AND REAR HOUSE ./4 EXIT LIGHTS - OUT OF SERVICE. | 9351 S UNIVERSITY AVE | COMPLAINT | FAILED | View |
| REPL DEFECTIVE BATHROOM FLOOR | FRONT HOUSE / 1ST FL BATHROOM FLOOR - 1X1 FT HOLE AND NO TILE ON THE FLOOR | 9351 S UNIVERSITY AVE | COMPLAINT | FAILED | View |
| REPAIR INTERIOR STAIR SYSTEM | FRONT HOUSE / 1ST FL INTERIOR STAIR - 1ST TO ATTIC SPIRAL STAIRCASE TREADS LOOSE .GUARDRAILS LOOSE .PICKETS MISSING AND NOT STABLE .PLANS AND PERMIT REQUIRED FR INTERIOR STAIRS | 9351 S UNIVERSITY AVE | COMPLAINT | FAILED | View |
| SUPPLY HOT WTR MIN TEMP 120DEG | FRONT HOUSE / 1ST FL BATHROOM / HOT WATER - TURN OFF ,PER SECTION CODE ) ) (14X-9-905.2, 14X-9-905.2.1 AND 14X-9BHA CODES | 9351 S UNIVERSITY AVE | COMPLAINT | FAILED | View |
| CARB MONOX DETECT IN RESID | FRONT HOUSE /1ST FL / CARBON MONOXIDE - MISSING .PER SECTION CODE . (14X-5-504.9, 14B-9-915.1.1, 14B-9-915.2 , AND 14R-11-1105) | 9351 S UNIVERSITY AVE | COMPLAINT | FAILED | View |