Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-23 @ 2:00 AM
PIN: 16142240260000
Property Address: 3503 W VAN BUREN ST
City - Zip: CHICAGO - 60624
2023 Property Class: 211
2023 Township: 77 - West Chicago
2023 Neighborhood: 77102
2023 Tax District: 77113
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 17 Violations
Violation Inspector Comments Address Category Status View
REPAIR PORCH SYSTEM REAR PORCH RAILS DEFLECT IMPROPER STRINGER CONNECTIONS 2X8 JOISTS OVER SPANNED CENTER UPRIGHT NOT CENTERED ON FOOTING PLANS & PERMITS REQUIRED FOR REPAIRS PORCH RECENTLY BUILT NO PERMIT ON FILE 3503 W VAN BUREN ST COMPLAINT FAILED View
REPAIR ROOF ROOF OVER 2ND FLOOR BAY WINDOW LEAKING INTO UNIT 3503 W VAN BUREN ST COMPLAINT FAILED View
REPAIR INTERIOR WALLS/CEILING 2ND THRU-OUT ALL CEILING WATER DAMAGE 3503 W VAN BUREN ST COMPLAINT FAILED View
INT WALL/CEILING PEELING PAINT 2ND LIVINGROOM PEELING PAINT 3503 W VAN BUREN ST COMPLAINT FAILED View
CARB MONOX DETECT IN RESID 2ND NO CARBON MONOXIDE 3503 W VAN BUREN ST COMPLAINT FAILED View
INSTALL DOOR VIEWING DEVICE 2ND DOOR NO VIEWING DEVICE 3503 W VAN BUREN ST COMPLAINT FAILED View
REPAIR PORCH SYSTEM REAR PORCH 2ND STRINGER OVERCUT,NO BOLTED TO BRICK WALL,RISERS SIZE VARIOUS,RAIL NOT ANCHOR TO WALL,AT GRADE TREADS CRACKING,2ND MISSING PICKETS REQUIRE PERMIT 3503 W VAN BUREN ST COMPLAINT FAILED View
INSTALL DOOR VIEWING DEVICE 2ND DOOR NO VEIWING DEVICE 3503 W VAN BUREN ST COMPLAINT FAILED View
REPAIR EXTERIOR STAIR FRONT CONCRETE STAIRWAY - STEPS CRUMBLING AND ROOF COLLAPSED - PERMIT REQUIRED FOR REPAIRS. 3503 W VAN BUREN ST COMPLAINT CLOSED View
POST OWNER/MANAGERS NAME/# BLDG. - OWNER'S I.D. SIGN - MISSING 3503 W VAN BUREN ST COMPLAINT CLOSED View
NO POSTED ADDRESS BLDG. - ADDRESS - INCOMPLETE 3503 W VAN BUREN ST COMPLAINT CLOSED View
ARRANGE PREMISE INSPECTION INTERIOR OF BLDG: NO RESPONSE - UNVERIFIED DETECTORS AND CONDITIONS. UNABLE TO INSPECT REAR PORCH AND VERIFY COMPLIANCE TO PREVIOUS VIOLATIONS - SEE INSPECTION # 10332554, WRITTEN ON 09/01/2011. 3503 W VAN BUREN ST COMPLAINT CLOSED View
REPAIR PORCH SYSTEM 2-STORY REAR PORCH ERECTED WITHOUT A PERMIT. 4X4 COLUMNS ERECTED ON CONCRETE SERVICE WALK WITHOUT BASES, AND 6X6 COLUMNS ERECTED ON CONCRETE BLOCKS WITHOUT BASE PLATES - FOUNDATION STATUS UNKNOWN. STRINGERS ARE OVERCUT AND ONLY TOE-NAILED TO MASONRY WALL. CRACKING TREAD AT GRADE, WITH VARYING RISER SIZES. PICKETS AT 2 LOOSE AND MISSING. PLANS AND PERMIT REQUIRED FOR REPAIRS. 3503 W VAN BUREN ST COMPLAINT FAILED View
PROVIDE GUARD RAIL 42 IN HIGH REAR BASEMENT STAIRWAY - GUARDRAIL SECTIONS ARE WOOD LATTICE, WITH ONLY 24 INCHES ABOVE THE GRADE. 3503 W VAN BUREN ST COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION INTERIOR OF BLDG: NO RESPONSE - UNVERIFIED DETECTORS AND CONDITIONS. UNABLE TO VERIFY COMPLIANCE TO PREVIOUS VIOLATIONS - SEE INSPECTION # 10332554, WRITTEN ON 09/01/2011 3503 W VAN BUREN ST COMPLAINT FAILED View
INT WALL/CEILING PEELING PAINT WALL & CEILING DAMAGED AT 2ND FLOOR BAY 3503 W VAN BUREN ST COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION NO ENTRY TO 1ST OR BASEMENT 3503 W VAN BUREN ST COMPLAINT FAILED View