HEAT UNIT ADEQUATELY | 6442 1ST FLOOR NO HEAT GAS SHUT OFF 52 DEGREES | 6440 S PARNELL AVE | COMPLAINT | PASSED | View |
INSTALL SMOKE DETECTORS | 6442 1ST FLOOR NO SMOKE DETECTOR | 6440 S PARNELL AVE | COMPLAINT | PASSED | View |
CARB MONOX DETECT IN RESID | 6442 1ST FLOOR NO CARBON MONOXIDE DETECTOR | 6440 S PARNELL AVE | COMPLAINT | PASSED | View |
REPLCE WINDOW PANES, PLEXGLAS | EAST ELEVATION 1ST AND 2ND FLOORS - BROKEN GLASS PANES. | 6440 S PARNELL AVE | COMPLAINT | FAILED | View |
SCREEN OUTER DOORS, WINDOWS | ALL ELEVATIONS AND LEVELS - MISSING WINDOW SCREENS. | 6440 S PARNELL AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | EAST ELEVATION, NORTH AND SOUTHEAST CORNERS 2ND FLOOR BRICKWORK IS BULGING OUT, CREATING A D&H CONDITION. MASONRY PERMIT REQUIRED FOR REPAIRS.INSTALL A HEAVY DUTY CANOPY TO PROTECT TENANTS FROM FALLING MATERIAL. | 6440 S PARNELL AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR 2 STORY WOOD PORCH: COLUMNS ARE ERECTED ON TOP OF CONCRETE BASES, FOUNDATION STATUS UNKNOWN.;UNDERSIZED 6"X6" BEAMS SPAN 6'-6" AND ARE FASTENED TO COLUMNS WITH NAILS ONLY.; UNDERSIZED 2"X6" DECK JOISTS SPAN 11'-4".; TREADS ARE ONLY 9-1/2" DEEP.; GUARDRAILS ARE ONLY 35-1/2" HIGH AND MISSING MANY PICKETS ON 1ST AND 2ND FLOOR, CREATING A DANGEROUS CONDITION.;HANDRAILS 1ST TO 2ND ARE LOOSE.; GUARDRAILS END POST TO WALL, STRINGERS AND RIM JOIST ARE FASTENED WITH NAILS ONLY.; GUARDRAIL SECTIONS OVER 4'-0" LONG INTERMEDI9ATE SUPPORT IS A PICKET.; PLANS AND PERMIT ARE REQUIRED TO REPAIR OR REPLACE PORCH.; ROOF - MISSING HATCH COVER. | 6440 S PARNELL AVE | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | FRONT AND REAR YARD - REFUSE ACCUMULATION. | 6440 S PARNELL AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | EXTERIOR WALL - NORTH EAST FACE BRICK SEPARATED FROM STRUCTURE, NORTH, SOUTH AND REAR ELEVATIONS SPALLED BRICK AND WASHED OUT MORTAR JOINTS PLANS AND PERMIT REQUIRED FOR MASONRY WORK (13.196.530(B), 13-196-641) | 6440 S PARNELL AVE | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | 6442 FIRST FLOOR NO CARBON MONOXIDE DETECTOR (13-64-190, 13-64-00) | 6440 S PARNELL AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW SASH | WINDOW SASHES LOOSE FIRST FLOOR 6442 REAR. (13-196-550(B)) | 6440 S PARNELL AVE | COMPLAINT | FAILED | View |
REPAIR SCREENS | TORN SCREENS ALL ELEVATIONS (13-196-560B) | 6440 S PARNELL AVE | COMPLAINT | FAILED | View |
SCREEN OUTER DOORS, WINDOWS | MISSING SCREEN ALL ELEVATION (13-196-560B) | 6440 S PARNELL AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR WOOD 2-STORY WOOD PORCH FOUNDATION - NOT VERIFIED COLUMNS - OVER NOTCHED FIRE CUT, BUTT JOINT AND TOE NAILED BEAMS - PULLING AWAY, LOOSE BRICK AT BEAM IN BRICK CONNECTION JOIST - UNDERSIZED RAILING - BROKEN PICKETS, LOOSE, TOENAILED, AND BELOW 42 INCHES STAIRS - OVER SPANNED, MISSING HATCH COVER. PLANS AND PERMIT ARE REQUIRED (13-196-570, 13-196-641) | 6440 S PARNELL AVE | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | REAR PORCH - TOILET, DEEP FREEZER, STOVE, REFRIGERATOR. (13-196-580-13-196630) | 6440 S PARNELL AVE | COMPLAINT | FAILED | View |
ABANDONED REFRIGERATOR | REAR PORCH SECOND FLOOR DEEP FREEZER (7-28-040) | 6440 S PARNELL AVE | COMPLAINT | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | REAR BASEMENT REAR STAIRS MISSING HANDRAIL AND PICKETS, HAS HORIZONTAL RAILS. 13-196-570, 13-196-641 | 6440 S PARNELL AVE | COMPLAINT | FAILED | View |
REPAIR/REPLACE SMOKE DETECTORS | 6442 FIRST FLOOR SMOKE DETECTOR "CHIRPING" MAINTENANCE REQUIRED 13-196-130, 13-196-140 | 6440 S PARNELL AVE | COMPLAINT | FAILED | View |
PROPER MATRL WATER SUPPLY PIPE | REMOVE UNAPPROVED FLEXIBLE SUPPLY LINES AT TOILET, LAVATORY AND KITCHEN SINK AT FIRST FLOOR AND THROUGHOUT THE PREMISES. 18-29-605 | 6440 S PARNELL AVE | COMPLAINT | FAILED | View |
INSTALL ILLUMINATION | INSTALL WEATHERPROOF ILLUMINATION AT EXTERIOR ENTRIES. (14E-7-700.6) | 6440 S PARNELL AVE | COMPLAINT | FAILED | View |
INSTALL COVERS | EXTERIOR BOXES, FITTING, FIXTURES MUST BE SUITABLE FOR WET LOCATION. (14E-1-110.3) | 6440 S PARNELL AVE | COMPLAINT | FAILED | View |
INSTALL COVERS | OPEN DISCONNECT LOWER REAR EXTERIOR. OPEN BOX REAR EXTERIOR. (14E-3-314.25) ALL DANGEROUS AND HAZARDOUS | 6440 S PARNELL AVE | COMPLAINT | FAILED | View |
DEFECTIVE FIXTURES | BROKEN LIGHT FIXTURES REAR EXTERIOR. (14E-4-410.20) | 6440 S PARNELL AVE | COMPLAINT | FAILED | View |
ABANDONED EQUIPMENT | ABANDONED SERVICE ENTRANCE CABLE REAR EXTERIOR. (14E-1-110.1 C) | 6440 S PARNELL AVE | COMPLAINT | FAILED | View |
DEFECTIVE SERVICE | SERVICE ENTRANCE CONDUCTORS DETERIORATED AT REAR 6440. (14E-2-230) | 6440 S PARNELL AVE | COMPLAINT | FAILED | View |
WORKING SPACE | PROVIDE WORKING SPACE AT METER ENCLOSURES REAR EXTERIOR. (14E-1-110.26) | 6440 S PARNELL AVE | COMPLAINT | FAILED | View |
NO PERMIT WIRING | PROVIDE PERMIT(S) FOR ELECTRICAL SERVICES INSTALLED WITHOUT PERMIT(S). (13-12-360) | 6440 S PARNELL AVE | COMPLAINT | FAILED | View |
CONTINUITY OF RACEWAYS | CONDUIT PULLED AWAY FROM BOX AT FROM EXTERIOR. (14E-3-300.1) DANGEROUS AND HAZARDOUS | 6440 S PARNELL AVE | COMPLAINT | FAILED | View |
SEE INSPECTOR COMMENTS | PROVIDE ACCESS TO INSPECT CONDITION OF ELECTRICAL SERVICE EQUIPMENT AND CONDITION OF APARTMENTS. (13-12-380) | 6440 S PARNELL AVE | COMPLAINT | FAILED | View |
TENANT ACCESS TO SERVICE | NO TENANT ACCESS TO SERVICE EQUIPMENT. (14E-2-230.72 C) | 6440 S PARNELL AVE | COMPLAINT | FAILED | View |
DEFECTIVE OUTLETS | REPLACE BROKEN DEVICES 6442 FIRST FLOOR AND WHERE REQUIRED IN TYPICAL UNITS THROUGHOUT FIRST FLOOR, SECOND FLOOR AND BASEMENT. (14E-4-406.4) | 6440 S PARNELL AVE | COMPLAINT | FAILED | View |
PROVIDE PERMIT(S) TO CORRECT VIOLATIONS. (13-12-360) | 6440 S PARNELL AVE | COMPLAINT | FAILED | View | |
STRAP SERVICE CONDUIT | SERVICE RISER SUPPORTS RUSTED. (14E-1-110.12 A) | 6440 S PARNELL AVE | COMPLAINT | FAILED | View |
PARAPET | PARAPET WALL - NORTH AND SOUTH ELEVATIONS, STRESS FRACTURES, SPALLED BRICK AND WASHED OUT MORTAR (13-196-530 (E) AND 13-196-641) | 6440 S PARNELL AVE | COMPLAINT | FAILED | View |
SUPPLY HOT WTR MIN TEMP 120DEG | 6442 1ST FLOOR NO HOT WATER GAS SHUT OFF | 6440 S PARNELL AVE | COMPLAINT | PASSED | View |
REPLCE WINDOW PANES, PLEXGLAS | BROKEN WINDOW PANES FRONT AND SECOND FLOOR NORTH (13-196-5504) | 6440 S PARNELL AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO BASEMENT SECOND UNITS AND 6440 FIRST SEE # (13-12-100) | 6440 S PARNELL AVE | COMPLAINT | FAILED | View |
PRV BALLCOCK,VB,OR AIR GAP | NO VACUUM BREAKER ON HOSEBIBS AT EAST ELEVATION. PROVIDE VACUUM BREAKER. 18-29-606.5.6 | 6440 S PARNELL AVE | COMPLAINT | FAILED | View |