Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
OWNER OR LICENSED CONTRACTOR | 1606 E 50TH PL | PERIODIC | PASSED | View | |
STOP/REMOVE NUISANCE | DEMO DEBRIS/JUNK-GARBAGE REAR | 1606 E 50TH PL | PERIODIC | FAILED | View |
RATS-ELEVATE MATERIAL 18" | PALLETS STACKED AT THE REAR OF BUILDING | 1606 E 50TH PL | PERIODIC | FAILED | View |
TEST G & S ALL ELE | EV008095 | 1606 E 50TH PL | PERIODIC | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | REPAIR OR REPLACE EMERGENCY ALARM BELL PASSENGER ELEVATORS | 1606 E 50TH PL | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PERFORM CATEGORY1 AND CATEGORY5 TEST ALL ELEVATORS | 1606 E 50TH PL | PERIODIC | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE CODE DATA PLATE ALL ELEVATORS | 1606 E 50TH PL | PERIODIC | PASSED | View |
EXPOSED WIRING | PARALLEL OPEN TEMPORARY FEEDERS FROM SWITCH GEAR ROOM THROUGH BIKE STORAGE AREA DANGEROUS & HAZARDOUS HAS BEEN TEMPORARY FOR 7 YEARS | 1606 E 50TH PL | COMPLAINT | FAILED | View |
GROUND EQUIPMENT | BASEMENT STORAGE AREA DISCONNECT ON FLOOR NO GROUND DANGEROUS AND HAZARDOUS | 1606 E 50TH PL | COMPLAINT | FAILED | View |
REMOVE EXPOSED CABLE | BASEMENT | 1606 E 50TH PL | COMPLAINT | FAILED | View |
PIPE OPENING W/NONCOMBUST MATL | AT ALL ELECTRICAL CLOSETS, ALL FLOORS, THROUGHOUT ENTIRE BASEMENT INCLUDING MECHANICAL AND ELECTRICAL ROOMS, REMOVE NOT APPROVED COMBUSTIBLE MATERIAL AND PROVIDE APPROVED FIRE MATERIAL TO FIRE STOP PROPERLY ALL PIPE AND EQUIPMENT PENETRATIONS.OPENINGS AROUND EXPOSED PIPES OR POWER SHAFTING SHALL BE FILLED WITH APPROVED NONCOMBUSTIBLE MATERIAL, OR SHALL BE CLOSED OFF BY CLOSE-FITTING METAL CAPS AT THE CEILING AND FLOOR LINE, AND ON EACH SIDE OF A WALL, CEILING OR PARTITION.AS PER BUILDING CODE 15-8-640 | 1606 E 50TH PL | PERIODIC | FAILED | View |
1HR ENCL FLR TO FLR SHAFT/DUCT | AT BASEMENT LEVEL, STARTING AT GARBAGE CHUTE, PENETRATING EVERY FLOOR ALL THE WAY UP TO THE ROOF SLAB, CLOSE, SEAL ALL PENETRATIONS WITH APPROVED FIRE STOPPING MATERIALS. | 1606 E 50TH PL | PERIODIC | FAILED | View |
PROVIDE | STAIRWELL IDENTIFICATIONAS PER CBC SECTION 13-76-075 PROVIDE STAIRWELL IDENTIFICATION AT EACH FLOOR ON INTERIOR OF STAIRWELL AND CORRIDOR | 1606 E 50TH PL | PERIODIC | FAILED | View |
NO POSTED ADDRESS | MISSING OWNER¿S IDENTIFICATION SIGN | 1606 E 50TH PL | PERIODIC | FAILED | View |
PROVIDE | AS PER SECTION 13-196-204 ONE AND TWO WAY VOICE COMMUNICATION SYSTEMAT THE TIME OF INSPECTION THE ONE AND TWO WAY VOICE COMMUNICATION SYSTEM INSTALLATION NOT COMPLETED AT THE TIME OF INSPECTION.SYSTEM IN PLACE BUT NOT WORKING "OFF" | 1606 E 50TH PL | PERIODIC | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | AT BOTH STAIRWELLS, INTERIOR HAND RAIL AND INTERIOR GURAD RAILING ARE OF LADDER TYPE WITH HORIZONTAL BARS SPACED 18" APART, GUARD RAIL IS ONLY 36" PERMIT REQUIRED TO REPAIR BOTH STAIRWELLS. | 1606 E 50TH PL | PERIODIC | FAILED | View |
SELF-CLOSE CLASS B FIRE DOOR | AT BOTH STAIRWELLS ALL DOORS, ALL FLOORS STAIRWELL DOORS ONLY HAVE SPRING LOADED HINGE DOORS CLOSERS. PROVIDE AT ALL FLOORS BOTH STAIRWELLS HEAVY DUTY UL APPROVED SELF CLOSING DEVICE.AT BOILER ROOM, PROVIDE SELF CLOSING / LATCHING "B" FIRE DOOR ASSEMBLY EXISTING DOOR NOT PROPERLY LABEL.AS PER ARCHITECTS RECOMENDATION AT BOILER ROOM REPAIR / REPLACE / PROVIDE PANIC BAR RELEASE. | 1606 E 50TH PL | PERIODIC | FAILED | View |
HEATING PLANT/BOILER ROOM DOOR | AT BOILER ROOM PROVIDE SELF CLOSING, SELF LATCHING CLASS "B" FIRE DOOR ASSAMBLY, EXISTING DOOR MISSING TAG AND SELF CLOSER. | 1606 E 50TH PL | PERIODIC | FAILED | View |
SELF-CLOSE DOOR >4 STORY RES. | AT THE FOLLOWING APARTMENTS ENTRY DOORS NOT CLOSING PROPERLY.13D, 11B, 10E, 10B. | 1606 E 50TH PL | PERIODIC | FAILED | View |
FIRE EXTNGSHR RECHARGE & TAG | AT WEST BASEMENT, TENANT STORAGE ROOM,FIRE EXTINGUISHERS MISSING TAG, RE CHARGE AND RE TAG ALL EXTIGUISHERS MISSING SERVICE TAG. | 1606 E 50TH PL | PERIODIC | FAILED | View |
MAINTAIN EXIT SIGN ILLUMINATED | AT BASEMENT LEVEL, THROUGHOUT ENTIRE STORAGE ROOM, PROVIDE EXIT AND DIRECTIONAL EXIST SIGNS.PROVIDE EMERGENCY EXIT SIGN AT BIKE ROOM. | 1606 E 50TH PL | PERIODIC | FAILED | View |
DOOR SWING IN DIR. OF TRAVEL | AT FITNESS ROOM EXTERIOR DOOR, DOOR SWING IS INCORRECT, PROVIDE SWING IN THE DIRECTION OF EXIT TRAVEL. | 1606 E 50TH PL | PERIODIC | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | EXTERIOR BASEMENT TO GRADE STAIRWAY, EXISTING GUARDRAIL ARE OF LADDER TYPE CONSTRUCTION WITH HORIZONTAL BARS SPACE 18" APART AND 36" IN HEIGHT. | 1606 E 50TH PL | PERIODIC | FAILED | View |
PROVIDE | SUBMIT DOCUMENTATION THAT RECESSED FOLDING STAIR SYSTEM ASSEMBLY IN CEILING AT 14TH FOURTEEN FLOOR TO MECHANICAL PENTHOUSE PROVIDES REQUIRED FIRE RESISTIVE SEPARATION AS PER 3 (13-64-020) (A) (B) | 1606 E 50TH PL | PERIODIC | FAILED | View |
UNAPPROVED HEATING DEVICE | UNIT 10E - USING STOVE AS HEATING DEVICE. | 1606 E 50TH PL | COMPLAINT | FAILED | View |
HEAT UNIT ADEQUATELY | UNIT 10E - LIVING ROOM 64 DEGREES F. BEDROOM 70 DEGREES F. HEATING SYSTEM IS ON AT TIME OF INSPECTION, HEAT IS INSUFFICIENT. | 1606 E 50TH PL | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | UNIT 10E - MISSING CARBON MONOXIDE DETECTOR. | 1606 E 50TH PL | COMPLAINT | FAILED | View |
PROVIDE | FAILED TO OBTAIN APPROVAL FOR IMPLEMENTATION OF LIFE SAFETY EVALUATION COMPLIANCE PLAN. (13-196-206D) | 1606 E 50TH PL | COMPLAINT | PASSED | View |
PROVIDE | FAILED TO OBTAIN APPROVAL FOR IMPLEMENTATION OF LIFE SAFETY EVALUATION COMPLIANCE PLAN. (13-196-206D) | 1606 E 50TH PL | COMPLAINT | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PERFORM CATAGORY 1 SAFETY TEST. | 1606 E 50TH PL | PERIODIC | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PERFORM CATEGORY 1 TEST ON BOTH ELEVATORS | 1606 E 50TH PL | PERIODIC | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | UPDATE FIRE SERVICE/ MAINTENANCE LOGS IN MACHINE ROOM | 1606 E 50TH PL | PERIODIC | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE ANTI-ROTATION DEVICE IN SHACKLES FOR ELEVATOR #2( FREIGHT) | 1606 E 50TH PL | PERIODIC | PASSED | View |
SUBMIT REVISED PLANS FOR PERMT | 1606 E 50TH PL | COMPLAINT | FAILED | View | |
REPLACE | GAS VALVE ON #1 FITZGERALD FIRE BOX BOILER. | 1606 E 50TH PL | PERIODIC | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | INSTALL CODE DATA PLATES ON CONTROLLERS PASSENGER AND FREIGHT | 1606 E 50TH PL | PERIODIC | FAILED | View |
CONTINUITY OF RACEWAYS | NO RACEWAY FOR FEEDERS | 1606 E 50TH PL | COMPLAINT | FAILED | View |
REMOVE TEMPS | TEMPORARY HAS BEEN THIS WAY FOR 7 YEARS | 1606 E 50TH PL | COMPLAINT | FAILED | View |