The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
13-12-360 PROVIDE PERMIT TO CORRECT VIOLATIONS. | 4057 W MAYPOLE AVE | COMPLAINT | FAILED | View | |
REPAIR PORCH SYSTEM | WOOD NORTH PORCH HAS HORIZONTAL PICKETS, UNDERSIZED GUARD RAILS, LOOSE HAND RAIL AND TREADS. SOUTH TOW STORY WOOD PORCH UNDERSIZED 2X6 FLOOR JOISTS, UNKNOWN FOOTINGS, MISSING JOIST HANGERS, UNEVEN RISER HEIGHTS, UNDERSIZED GUARD RAILS, MISSING ANCHOR BOLTS AND HEADERS TO BUILDING. | 4057 W MAYPOLE AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | REPAIR OR REPLACE NORTH/SOUTH WOOD PORCHES WILL REQUIRE PLANS AND OR PERMITS. | 4057 W MAYPOLE AVE | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | STEEL PICKET FENCE OVER 5 FEET. REDUCE HEIGHT, REMOVE OR OBTAIN A PERMIT. | 4057 W MAYPOLE AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | 1ST AND 2ND FLOOR INTERIOR STAIRS HAS BROKEN HAND RAIL AT 2ND FLOOR LANDING MISSING PICKETS. | 4057 W MAYPOLE AVE | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | SERVICE WALK HAS BROKEN CONCRETE CAUSING A TRIP HAZARD. | 4057 W MAYPOLE AVE | COMPLAINT | FAILED | View |
CHIMNEY CAPPING | CHIMNEY MISSING CAP. | 4057 W MAYPOLE AVE | COMPLAINT | FAILED | View |
PRV GREASE INTCPT OR CTH BASIN | CATCH BASIN COVER MISSING SOUTH ELEVATION. | 4057 W MAYPOLE AVE | COMPLAINT | FAILED | View |
INSTALL ILLUMINATION | INSTALL ILLUMINATION TO FRONT ENTRY DOORS. | 4057 W MAYPOLE AVE | COMPLAINT | FAILED | View |
DEFECTIVE FIXTURES | REPLACE DEFECTIVE LIGHT FIXTURES AT FRONT AND REAR ENTRY DOORS. ALL FIXTURES AND SUPPORT BOXES MUST BE WEATHERPROOF. | 4057 W MAYPOLE AVE | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | ALL BASEMENT EXIT DOORS EAST AND NORTH HAVE PADLOCKED SECURITY GATES. | 4057 W MAYPOLE AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | BASEMENT MISSING SMOKE DETECTOR. | 4057 W MAYPOLE AVE | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | BASEMENT AND 2ND FLOOR MISSING CO DETECTORS. | 4057 W MAYPOLE AVE | COMPLAINT | FAILED | View |
REPLACE DEFECTIVE FAUCET | HOT AND COLD HANDLES MISSING TUB VALVE, 1ST FLOOR RESTROOM. | 4057 W MAYPOLE AVE | COMPLAINT | FAILED | View |
PROPER MATRL WATER SUPPLY PIPE | REMOVE FLEXIBLE SUPPLIES TO KITCHEN FAUCET, LAVATORY TOILET 1ST FLOOR. | 4057 W MAYPOLE AVE | COMPLAINT | FAILED | View |
INSTALL ILLUMINATION | INSTALL ILLUMINATION TO ALL EXTERIOR ENTRY DOORS. | 4057 W MAYPOLE AVE | COMPLAINT | FAILED | View |
HEAT UNIT ADEQUATELY | 1ST FLOOR APARTMENT - ROOM TEMPERATURE 56 DEGREES F. AT 12:28 PM. HEATING SYSTEM IS OFF AT TIME OF INSPECTION, NO HEAT PROVIDED. GAS SERVICE - SHUT OFF, NO HEAT PROVIDED. | 4057 W MAYPOLE AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | 1ST FLOOR APARTMENT - MISSING SMOKE DETECTOR. | 4057 W MAYPOLE AVE | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | 1ST FLOOR APARTMENT - MISSING CARBON MONOXIDE DETECTOR. | 4057 W MAYPOLE AVE | COMPLAINT | FAILED | View |
REPAIR WINDOW SILLS | EAST AT 2ND FLOOR HAS CRACKED WINDOW SILL. | 4057 W MAYPOLE AVE | COMPLAINT | FAILED | View |
BASEMENT, DISCONTINUE | BASEMENT ORIGINAL CONFIGURATION WAS FOR MECHANICALS AND STORAGE. CURRENT CONFIGURATION HAS TWO BEDROOMS AND A BATH. | 4057 W MAYPOLE AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | BASEMENT HAS NON LOAD BEARING PARTITION WALLS FORMING TWO BEDROOMS AND ONE BATH. OBTAIN PLANS AND PERMITS. | 4057 W MAYPOLE AVE | COMPLAINT | FAILED | View |
REPAIR DEFECTIVE FOUNDATION | NORTH GRADE TO BASEMENT HAS BROKEN AND DETERIORATED FOUNDATION WALL. | 4057 W MAYPOLE AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | STRUCTURAL REPAIRS TO BASEMENT FLOOR JOISTS AND SUPPORT COLUMNS WILL REQUIRE PLANS AND PERMITS. | 4057 W MAYPOLE AVE | COMPLAINT | FAILED | View |
VENT SYSTEM TO PRVNT BACK PRES | NO VENT ON DOUBLE COMPARTMENT SINK SOUTH ELEVATION BASEMENT. | 4057 W MAYPOLE AVE | COMPLAINT | FAILED | View |
PROPER MATRL WATER SUPPLY PIPE | REMOVE FLEXIBLE SUPPLIES TO LAVATORY, TOILET, DOUBLE COMPARTMENT SINK AND HOT SIDE OF WATER HEATER BASEMENT. | 4057 W MAYPOLE AVE | COMPLAINT | FAILED | View |
OBTAIN PERMIT FOR PLUMBING | NO PERMIT TO REMOVE CAST IRON WASTE AND VENT PIPING, AND REPLACE WITH PVC WASTE AND VENT PIPING ENTIRE BUILDING, PIPING NOT UP TO CHICAGO CODE. | 4057 W MAYPOLE AVE | COMPLAINT | FAILED | View |
STOP LEAKING WATER | 1 1/2 WASTE LINE FOR DOUBLE COMPARTMENT SINK IS DRAINING ON TO BASEMENT FLOOR. | 4057 W MAYPOLE AVE | COMPLAINT | FAILED | View |
REPLACE DEFECTIVE FAUCET | TUB SPOUT TO FAR AWAY FROM WALL. 1ST FLOOR RESTROOM. | 4057 W MAYPOLE AVE | COMPLAINT | FAILED | View |
LICENSED BONDED PLMBG CONTRCTR | OBTAIN A LICENSE FOR PLUMBER TO DO PLUMBING WORK. | 4057 W MAYPOLE AVE | COMPLAINT | FAILED | View |
DEFECTIVE METER EQUIPMENT | REPLACE DEFECTIVE AND VANDALIZED POWER SERVICE WITH DAMAGED RISER METER SOCKET AND PANELS. INSTALL PUBLIC PANEL AND PUBLIC METER. D&H. | 4057 W MAYPOLE AVE | COMPLAINT | FAILED | View |
DEFECTIVE FIXTURES | REPLACE DEFECTIVE LIGHT FIXTURES MISSING GLOBES, BASEMENT 1ST FLOOR AND 2ND FLOOR. INCLUDING EXTERIOR LIGHT FIXTURE AT REAR PORCH AREA SUPPORT BOXES MUST BE WEATHERPROOF | 4057 W MAYPOLE AVE | COMPLAINT | FAILED | View |
INSTALL COVERS | INSTALL COVERS TO ALL OPEN BOXES AND PANELS IN BASEMENT. D&H. | 4057 W MAYPOLE AVE | COMPLAINT | FAILED | View |
PROVIDE PERMIT TO CORRECT VIOLATIONS. (13.12.360) | 4057 W MAYPOLE AVE | COMPLAINT | FAILED | View | |
ARRANGE PREMISE INSPECTION | NO ENTRY TO INTERIOR OF BUILDING. | 4057 W MAYPOLE AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | NO OWNER POSTING. | 4057 W MAYPOLE AVE | COMPLAINT | FAILED | View |
REMOVE | GANG GRAFFITI ON FRONT ENTRY DOOR (7-28-065) | 4057 W MAYPOLE AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | WEST WALL HAS LOOSE/DETERIORATED BRICK WITH LOOSE AND MISSING MORTAR. | 4057 W MAYPOLE AVE | COMPLAINT | FAILED | View |
DEFECTIVE METER EQUIPMENT | REPLACE DEFECTIVE RISER AND IMPROPERLY INSTALLED SERVICE RISER. MUST BE PIPED TO END OF OPEN PORCH. | 4057 W MAYPOLE AVE | COMPLAINT | FAILED | View |
SERVICE DROP OUT OF REACH | RELOCATE SERVICE DROP OUT OF NORMAL REACH. | 4057 W MAYPOLE AVE | COMPLAINT | FAILED | View |
REPAIR FLOOR | 1 FLOOR KITCHEN FLOOR HAS HOLE AT SINK BASE. ROTTED AND WATER SOAKED SUB FLOORING KITCHEN AND HALL HAS DEFLECTION WHEN WALKED ON. SUB FLOOR AT 1ST/2ND FLOOR IS OSB MATERIAL. 2ND FLOOR FLOOR AT KITCHEN/HALL IS STARTING TO ROT AND SPLIT. ALSO HAS DEFLECTION. THE 1ST/2ND FLOOR KITCHEN AND HALLWAY ARE OF A DANGEROUS AND HAZARDOUS CONDITION. 2ND FLOOR HALL FLOOR DROPS 1 INCH. | 4057 W MAYPOLE AVE | COMPLAINT | FAILED | View |
SUBMIT STRUCT. ENG. RPT (INT.) | BASEMENT UTILITY ROOM HAS 6 ROTTED AND DETERIORATED 2 BY 10 FLOOR JOISTS SEVERAL HAVE BEEN SISTERED WITH NEWER 2 BY 10'S BUT WORKMANSHIP IS OF POOR QUALITY. 1 5 BY 8 WOOD SUPPORT COLUMN IS SPLIT DOWN CENTER WITH GAPS AT 1/4TH INCH AND ROTTED AT BASED. 1 5 BY 8 WOOD SUPPORT COLUMN IS OUT OF PLUMB. A INTERIOR STRUCTURAL ENGINEERS REPORT IS REQUIRED. | 4057 W MAYPOLE AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | WEST INTERIOR STAIRS 1ST FLOOR TO BASEMENT HAVE INCORRECT TREAD WIDTHS ARE AT 7 INCHES AND THE RISERS ARE AT 9 INCHES. SOME TREADS ARE LOOSE AND COVERED IN CARPET. USE OF THESE STAIRS ARE DANGEROUS AND HAZARDOUS. | 4057 W MAYPOLE AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | 2ND FLOOR SOUTH AND 1ST FLOOR NORTH HAVE BROKEN WINDOWS. | 4057 W MAYPOLE AVE | COMPLAINT | FAILED | View |
CHIMNEY | CHIMNEY HAS LOOSE/MISSING MORTAR. | 4057 W MAYPOLE AVE | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | DRUG WRAPPERS IN COMMON STAIRWAY. | 4057 W MAYPOLE AVE | COMPLAINT | FAILED | View |
STOP LEAKING WATER | 1ST FLOOR KITCHEN SINK LEAKS. | 4057 W MAYPOLE AVE | COMPLAINT | FAILED | View |
SUPPLY HOT WTR MIN TEMP 120DEG | 1ST FLOOR APARTMENT - GAS SERVICE SHUT OFF, NO HOT WATER PROVIDED. | 4057 W MAYPOLE AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | GRADE TO BASEMENT MISSING HAND RAIL. | 4057 W MAYPOLE AVE | COMPLAINT | FAILED | View |
RMV PLBFIX INSTALLD W/0 PERMIT | NO PERMIT FOR LAVATORY, TOILET, TUB AND DOUBLE COMPARTMENT SINK. BASEMENT. | 4057 W MAYPOLE AVE | COMPLAINT | FAILED | View |
CLEAN CATCH BASIN | CATCH BASIN FULL OF DEBRIS | 4057 W MAYPOLE AVE | COMPLAINT | FAILED | View |
INSTALL DOOR VIEWING DEVICE | ENTRY DOORS MISSING PEEP HOLES. | 4057 W MAYPOLE AVE | COMPLAINT | FAILED | View |
OBTN PERMIT FOR PLUMBING WORK | PERMIT FOR VIOLATIONS. | 4057 W MAYPOLE AVE | COMPLAINT | FAILED | View |
PROPERLY GROUND SERVICE TO LINE SIDE OF WATER/MAIN. (18.27.250.50) | 4057 W MAYPOLE AVE | COMPLAINT | FAILED | View |