Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
FIRE EXTNGSHR RECHARGE & TAG | EXPIRED TAGS AT EXTINGUISHER SYSTEM FRONT OF STORE | 401 N LARAMIE AVE | COMPLAINT | PASSED | View |
REPAIR EAVES | ROTTED FACCIA BOARD EAST ELEVATION | 401 N LARAMIE AVE | COMPLAINT | PASSED | View |
REPAIR EXTERIOR WALL | OPEN MORTAR JOISTS EAST ELEVATION TOWARD ROOFING NEAR TO COMPRESSOR | 401 N LARAMIE AVE | COMPLAINT | PASSED | View |
CHIMNEY | DANGEROUS LOOSE BRICKS AT EAST CHIMNEY OVER PARKING LOT | 401 N LARAMIE AVE | COMPLAINT | PASSED | View |
CHIMNEY CAPPING | MISSING CHIMNEY CAP EAST ELEVATION | 401 N LARAMIE AVE | COMPLAINT | PASSED | View |
REPAIR FLOOR | MISSING ONE FLOOR TILE AT EAST STORAGE ROOM | 401 N LARAMIE AVE | COMPLAINT | PASSED | View |
REPAIR INTERIOR WALLS/CEILING | HOLE IN SOUTH WALL OF WEST BATHROOM | 401 N LARAMIE AVE | COMPLAINT | PASSED | View |
ILLUMINATE PUBLIC STAIR/HALL | EXIT LIGHT AT SOUTH WALL NOT LIT | 401 N LARAMIE AVE | COMPLAINT | PASSED | View |
INSTALL SMOKE DETECTORS | MISSING SMOKE DETECTOR | 401 N LARAMIE AVE | COMPLAINT | PASSED | View |
CARB MONOX DETECT IN RESID | MISSING CARBON MONOXIDE DETECTOR | 401 N LARAMIE AVE | COMPLAINT | PASSED | View |
SOIL/WASTE,VENT PIPE MATRL | REMOVE PLASTIC WASTE PIPE UNDER HAND SINK AND OUTSIDE BEHIND HAND SINK | 401 N LARAMIE AVE | COMPLAINT | PASSED | View |
RPL CONCEALED COMPR/FLARED FIT | REMOVE COMPRESSION VALVES ON WATER HEATER | 401 N LARAMIE AVE | COMPLAINT | PASSED | View |
PROVIDE AIR CHAMERS | PROVIDE AIR CHAMBERS UNDER LAVATORY AND HAND SINK | 401 N LARAMIE AVE | COMPLAINT | PASSED | View |
REPAIR DEFECTIVE DOWNSPOUT | PROVIDE GUTTER ON REAR OF BUILDING | 401 N LARAMIE AVE | COMPLAINT | PASSED | View |
OBTN PERMIT FOR PLUMBING WORK | (18-29-106.1) | 401 N LARAMIE AVE | COMPLAINT | PASSED | View |
LICENSED BONDED PLMBG CONTRCTR | (18-29-106.1) | 401 N LARAMIE AVE | COMPLAINT | PASSED | View |
UNAPPROVED CORDS | REMOVE UNPROVED CORDS THROUGH OUT STORE | 401 N LARAMIE AVE | COMPLAINT | PASSED | View |
CARB MONOX DETECT IN RESID | CARBON MONOXIDE DETECTOR BEEPING DANGEROUS AND HAZARDOUS 14X-5-504.9 | 401 N LARAMIE AVE | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | AISLES OBSTRUCTED THROUGH OUT WITH EXCESSIVE STORAGE 21,20,-20" DANGEROUS AND HAZARDOUS 14X-5-505.1.2 | 401 N LARAMIE AVE | COMPLAINT | FAILED | View |
ARRANGE FOR REINSPECTION REGAR | PROVIDE ACCESS TO CEILING, REMOVE CEILING TILES FOR FULL INSPECTION STRUCTURAL AND MECHANICAL 14A-1-104.7 | 401 N LARAMIE AVE | COMPLAINT | FAILED | View |
RESTORE EXIT AND EM | PROVIDE MAINTENANCE OF SYSTEM 3 EXIT SIGN AND EM LIGHTS DANGEROUS AND HAZARDOUS CONDITION | 401 N LARAMIE AVE | COMPLAINT | FAILED | View |
LISTED FOR USE TEMP & LOCATION | PROVIDE WEATHER PROOF COVER FOR WEATHER PROOF LIGHT FIXTURE MISSING COVER AT EXTERIOR AREA OF BUILDING | 401 N LARAMIE AVE | COMPLAINT | FAILED | View |
OBTAIN ELECTRICAL PERMIT AND CONTRACTOR TO CORRECT VIOLATIONS AND LIGHTS ALTERED WITHOUT PERMITS 14A-4-404.6 | 401 N LARAMIE AVE | COMPLAINT | FAILED | View | |
REPAIR**************** | NO ELECTRICAL VIOLATIONS FIXED AT THIS TIME (18-27-110.12) | 401 N LARAMIE AVE | PERMIT | FAILED | View |
REMOVE AND REPLACE***** | NO ELECTRICAL VIOLATIONS FIXED AT THIS TIME (18-27-110.12) | 401 N LARAMIE AVE | PERMIT | CLOSED | View |
PROPER MATRL WATER SUPPLY PIPE | REMOVE FLEXIBLE SUPPLYS TO HAND SINK NEXT TO THREE COMPARTMENT SINK | 401 N LARAMIE AVE | COMPLAINT | FAILED | View |
REPAIR FLOOR | BROKEN FLOOR TILES | 401 N LARAMIE AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | WATER DAMAGED CEILING TILES | 401 N LARAMIE AVE | COMPLAINT | FAILED | View |
PROVIDE | SOUTH REAR EXIT DOOR AT SIX FEET - 7 INCHES (13-160-070, 13-64-050) | 401 N LARAMIE AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | NORTH WALL HAS LOOSE AND MISSING BRICK AND MORTAR | 401 N LARAMIE AVE | COMPLAINT | FAILED | View |
REPAIR DOWNSPOUT | NORTH DOWNSPOUT MISSING A SECTION | 401 N LARAMIE AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | NEW STRUCTURAL ROOF TRUSSES AND SHEATHING REPLACE AT EAST ELEVATIONS A EPP #100466194 WAS APPLIED FOR ON 11/04/12 BUT WAS VOIDED - NOT PAID PROPER PLANS AND PERMITS REQUIRED | 401 N LARAMIE AVE | COMPLAINT | FAILED | View |
SUBMIT STRUCT. ENG. RPT (INT.) | A STRUCTURAL ENGINEERS REPORT IS REQUIRED FOR ROOF REPAIRS | 401 N LARAMIE AVE | COMPLAINT | FAILED | View |
RMV PLBFIX INSTALLD W/0 PERMIT | NO PERMIT TO INSTALL THREE COMPARTMENT SINK AND THREE HANDSINKS | 401 N LARAMIE AVE | COMPLAINT | FAILED | View |
OBTN PERMIT FOR PLUMBING WORK | PERMIT FOR VIOLATION | 401 N LARAMIE AVE | COMPLAINT | FAILED | View |
DEFECTIVE FIXTURES | REPLACE BROKEN AND DEFECTIVE LIGHT FIXTURE ON EXTERIOR UNDER CANOPY STRUCK BY AUTO MOBILE | 401 N LARAMIE AVE | COMPLAINT | FAILED | View |
CORRODED CONDUIT & EQUIP | REPLACE DEFECTIVE AND BROKEN CONDUITS ON EXTERIOR STRUCK BY AUTO MOBILE | 401 N LARAMIE AVE | COMPLAINT | FAILED | View |
REMOVE IMPROPER INSTALLATIONS OF CONDUITS ABOVE ACOUSTICAL CEILING. INSTALL MINIMUM 12X12X6 JUNCTION BOX WHERE MULTIPLE CONDUIT CONNECTIONS 18-27-110.5 | 401 N LARAMIE AVE | COMPLAINT | FAILED | View | |
UNAPPROVED CORDS | REMOVE ALL CORD CONNECTIONS TO LITE FIXTURES AT ROOF LINE. ALL ELECTRICAL EUIPMENT MUST BE WEATHER PROOF INCLUDING SIGN CONNECTION | 401 N LARAMIE AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | WEST ELEVATION/EXTERIOR DOOR-MISSING HANDLE | 401 N LARAMIE AVE | COMPLAINT | PASSED | View |
REPAIR FLOOR | BATHROOM/FLOOR-TILE BROKEN | 401 N LARAMIE AVE | COMPLAINT | PASSED | View |
OBSTRUCTIONS IN EXIT WAY | REAR STORAGE AREAS/OVERSTOCK BLOCKING AISLE-ONLY 10"-24" WIDE | 401 N LARAMIE AVE | COMPLAINT | PASSED | View |
BUILDING IN DISREPAIR | EAST ELEVATION/VERTICAL STRESS FRACTURES WALL SUBSTANTIALLY OUT OF PLUMB LEANING. NORTH ELEVATION WASHED OUT MORTAR, AND SHIFTING BRICK (STORE HAS A DRIVE-THRU) (DANGEROUS) | 401 N LARAMIE AVE | COMPLAINT | PASSED | View |
REPAIR GUTTER & DOWNSPOUT | WEST ELEVATION/GUTTERS BENT, NORTH ELEVATION DOWNSPOUT MISSING | 401 N LARAMIE AVE | COMPLAINT | PASSED | View |
CHIMNEY | CHIMNEY/WASHED OUT MORTAR AND VERTICAL FRACTURES PULLING AWAY FROM EXTERIOR WALL | 401 N LARAMIE AVE | COMPLAINT | PASSED | View |
REPAIR INTERIOR WALLS/CEILING | REAR ADDITION/DRYWALL BROKEN, MISSING, LOOSE SECTIONS, CEILING DROPPED ABOUT 4' FEET | 401 N LARAMIE AVE | COMPLAINT | PASSED | View |
INT WALL/CEILING PEELING PAINT | CEILING GRID TIE-OFF SPORADICALLY. TILES LOOSE. | 401 N LARAMIE AVE | COMPLAINT | PASSED | View |
DEBRIS, EXCESSIVE | REAR ACCUMULATION OF TRASH | 401 N LARAMIE AVE | COMPLAINT | PASSED | View |
PLANS & PERMITS REQ - CONTRCTR | INTERIOR/PARTITIONS ERECTED CEILING DROPPED "I" BEAM INSTALLED. REAR ADDITION ERECTED WITHOUT PLAN OR PERMIT. SUBMIT PLANS AND OBTAIN PERMIT FOR ALL ALTERATIONS TO BUILDING. | 401 N LARAMIE AVE | COMPLAINT | PASSED | View |
PROVIDE GREASE INTERCEPTOR | 3 COMPARTMENT SINK-REMOVE THE DOUBLE TRAP AND "S" TRAP AND PIPE THROUGH A GREASE TRAP (18-29-1003.3.1) | 401 N LARAMIE AVE | COMPLAINT | PASSED | View |
REPLACE DEFECTIVE WASTE PIPING | LAUNDRY TUB-REMOVE PVC ACCORDIAN STYLE WASTE PIPING (18-29-102.3) | 401 N LARAMIE AVE | COMPLAINT | PASSED | View |
INSTALL SUFFICIENT FIXTURES | INSTALL HAND SINK IN FOOD PREP AREA (18-29-403.1) | 401 N LARAMIE AVE | COMPLAINT | PASSED | View |
REPLACE DEFECTIVE WATER PIPING | WATER HEATER-WATER PIPE SIZE IS TOO SMALL FOR HEATER AND THE REST OF THE BUILDING (18-29-102.3 | 401 N LARAMIE AVE | COMPLAINT | PASSED | View |
OPEN | WATER HEATER-INSTALL A FLOOR DREAIN WITHIN THE ROOM FOR THE WATER HEATER (18-29-412.4) | 401 N LARAMIE AVE | COMPLAINT | PASSED | View |
PRV DISCHARGE PIPE FROM PRV | WATER HEATER-REMOVE PVC RELIEF PIPING AND REPLACE WITH AN APPROVED MATERIAL (18-29-504.7.1) | 401 N LARAMIE AVE | COMPLAINT | PASSED | View |
REPLACE DEFECTIVE WASTE PIPING | EMPLOYEE BATHROOM-LAVATORY-REMOVE PVC WASTE PIPING (18-29-102.3) | 401 N LARAMIE AVE | COMPLAINT | PASSED | View |
ARMORED CABLE | REMOVE DEFECTIVE AND EXCESSIVE USE OF ARMOURED CABLE THRU OUT CEILING AREAS WITH EXPOSE WIRES - DANGEROUS AND HAZARDOUS CONDITION | 401 N LARAMIE AVE | COMPLAINT | PASSED | View |
PROPER MATRL WATER SUPPLY PIPE | EMPLOYEE BATHROOM-LAVATORY-REMOVE PVC WATER SUPPLIES AND INSTALL APPROVED WASTE PIPE MATERIALS (18-29-605) | 401 N LARAMIE AVE | COMPLAINT | PASSED | View |
PROVIDE OPEN FRONT TOILET SEAT | EMPLOYEE BATHROOM-INSTALL OPEN FRONT TOILET SEAT (18-29-420.3) | 401 N LARAMIE AVE | COMPLAINT | PASSED | View |
ENGAG LIC & BOND PLMBNG CNTRC | HIRE A LICENSED PLUMBING CONTRACTOR (18-29-106.3) | 401 N LARAMIE AVE | COMPLAINT | PASSED | View |
OBTN PERMIT FOR PLUMBING WORK | PULL A PLUMBING PERMIT. 18-29-106.1 | 401 N LARAMIE AVE | COMPLAINT | PASSED | View |
WORKING SPACE | PROVIDE PROPER CLEARANCE FOR ELECTRICAL PANEL | 401 N LARAMIE AVE | COMPLAINT | PASSED | View |
CONTINUITY OF RACEWAY | PROVIDE GROUND CONTINUITY FOR ARMOURED CABLE THRU OUT CEILING AREAS AND EXTERIOR LITES AROUND BUILDING - DANGEROUS AND HAZARDOUS CONDITION | 401 N LARAMIE AVE | COMPLAINT | PASSED | View |
SUPPORT FIXTURES | PROPERLY SUPPORT LIFE FIXTURES THRU OUT STORE AREAS | 401 N LARAMIE AVE | COMPLAINT | PASSED | View |
SECURE RACEWAY | PROPERLY SUPPORT ALL CONDUIT RUNS AT ELECTRICAL PANEL AREA AND THRU OUT ALL CEILING AREAS | 401 N LARAMIE AVE | COMPLAINT | PASSED | View |
SEE INSPECTOR COMMENTS | ALL BOXES SHALL BE ACCESSIBLE, COVERED, COMPLY WITH THE DIMENSION REQUIREMENTS OF ARTICLE 370-JUNCTION BOXES BURRIED UP IN ALL CEILING AREAS-18-27-370 | 401 N LARAMIE AVE | COMPLAINT | PASSED | View |
STOP/REMOVE NUISANCE | EXCESSIVE STORAGE THROUGHOUT, FLOOR AND LOFT AREA CAUSING FIRE HAZARD 14X-3-307 | 401 N LARAMIE AVE | COMPLAINT | FAILED | View |
1/2HR FLR OVER BSMT,3+DU,PRE57 | FURNACE ROOM DOOR MISSING CLOSER DANGEROUS AND HAZARDOUS 14X-5-502.8 | 401 N LARAMIE AVE | COMPLAINT | FAILED | View |
REPAIR GUTTER & DOWNSPOUT | GUTTERS SOUTH DAMAGED AND MISSING DOWNSPOUT 14X-3-303.7 | 401 N LARAMIE AVE | COMPLAINT | FAILED | View |
PROVIDE OPEN FRONT TOILET SEAT | NO OPEN FRONT TOILET SEAT | 401 N LARAMIE AVE | COMPLAINT | FAILED | View |
COMPLETE WORK | PROVIDE FULL STRUCTURAL REPORT PLANS AND PERMIT FROM 8-14-20218 #100777710 PERMIT OPEN 14A-4-413.9 | 401 N LARAMIE AVE | COMPLAINT | FAILED | View |
PROVIDE ADEQUATE DRAINAGE | ROOF EVIDENCE OF WATER PENETRATION, WATER DAMAGED CEILING TILES 14X-3-303.7 | 401 N LARAMIE AVE | COMPLAINT | FAILED | View |
DEFECTIVE FIXTURES | ALTERED LIGHT FIXTURES WITH EXPOSE WIRING DANGEROUS AND HAZARDOUS CONDITION | 401 N LARAMIE AVE | COMPLAINT | FAILED | View |
WORKING SPACE | PROVIDE PROPER CLEARANCE FOR ELECTRICAL PANELS, NEED TO MOVE ALL DEBRIS AND STOCK FROM PANEL AREA DANGEROUS AND HAZARDOUS | 401 N LARAMIE AVE | COMPLAINT | FAILED | View |
THE LOCATION OF SERVICE DISCONNECT PANEL SHALL NOT BE LOCATED IN BATHROOM AREA DANGEROUS AND HAZARDOUS CONDITION 14E-2-230.70 A 3 | 401 N LARAMIE AVE | COMPLAINT | FAILED | View | |
REPLACE DEFECTIVE FAUCET | LAUNDRY TUB FAUCET LEAKING | 401 N LARAMIE AVE | COMPLAINT | FAILED | View |
REPAIR ROOF | TORN ROOFING SOUTH ELEVATION | 401 N LARAMIE AVE | COMPLAINT | PASSED | View |
PROPER MATRL WATER SUPPLY PIPE | REMOVE FLEX WATER SUPPLY ON WATER HEATER | 401 N LARAMIE AVE | COMPLAINT | PASSED | View |
UNINTERRUPTED EXIT AT GRADE | MERCHANTILE/BEHIND COUNTER-EXIT DOOR BLOCKED WITH STOCK. | 401 N LARAMIE AVE | COMPLAINT | PASSED | View |
ALL ELECTRICAL CONDUIT BOXES WIRING AND ELECTRICAL EQUIPMENT SHALL BE INSTALLED IN A NEAT AND WORKMAN LIKE MANNER-18-27-110.12-CONDUIT RUNS, BOXES THRU OUT CEILING AND STORE AREAS. | 401 N LARAMIE AVE | COMPLAINT | PASSED | View | |
RATS | RAT DROPPING | 401 N LARAMIE AVE | COMPLAINT | PASSED | View |
ADD RECEPTACLES | ADD RECEPTACLES TO EASE EXTENSION CORD USE THRU OUT STORE AREA-DANGEROUS AND HAZARDOUS CONDITIONS | 401 N LARAMIE AVE | COMPLAINT | PASSED | View |
REPAIR**************** | MAIN BREAKER OF ELECTRICAL PANEL SHALL NOT EXCEED HEIGHT 6 FOOT 7 INCHES-18-27-380.8 | 401 N LARAMIE AVE | COMPLAINT | PASSED | View |
INSTALL COVERS | PROVIDE PROPER TYPE COVERS FOR OPEN BOXES WITH EXPOSE WIRES THRU OUT CEILING AREAS | 401 N LARAMIE AVE | COMPLAINT | PASSED | View |
REMOVE************** | OBTAIN ELECTRICAL PERMIT AND CONTRACTOR TO CORRECT VIOLATIONS 13-12-360 | 401 N LARAMIE AVE | COMPLAINT | PASSED | View |
HEATING PLANT/BOILER ROOM DOOR | HEATING PLANT ROOM/DOOR RATING NOT VISIBLE | 401 N LARAMIE AVE | COMPLAINT | PASSED | View |
REPAIR OR REPLACE | MERCHANTILE-DRUG WRAPPING (PLASTIC BAGS) | 401 N LARAMIE AVE | COMPLAINT | PASSED | View |
PROVIDE WEATHER PROOF BOXES, LITES, FITTINGS, AND APPROVED RACEWAYS FOR ALL EXTERIOR LITES-18-27-110.11 | 401 N LARAMIE AVE | COMPLAINT | PASSED | View | |
PROVIDE | VARIOUS AISLES BEHIND EMPLOYEE AREA AT TWENTY-SIX INCHES, TWENTY-EIGHT INCHES, TWENTY-SIX INCHES (15-4-880, 15-4-900) | 401 N LARAMIE AVE | COMPLAINT | FAILED | View |
REMV OBSTR FROM DRAINAGE SYSTM | HAND SINK NORTH ELEVATION DOES NOT DRAIN | 401 N LARAMIE AVE | COMPLAINT | FAILED | View |
RESET LOOSE FIXTURE | HAND SINK NEXT TO THREE COMPARTMENT SINK | 401 N LARAMIE AVE | COMPLAINT | FAILED | View |
LICENSED BONDED PLMBG CONTRCTR | OBTAIN A LICENSE PLUMBER TO DO PLUMBING WORK | 401 N LARAMIE AVE | COMPLAINT | FAILED | View |
PROVIDE PERMIT TO CORRECT VIOLATIONS 13-12-360 | 401 N LARAMIE AVE | COMPLAINT | FAILED | View |