Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR PORCH SYSTEM | NORTHWEST PORCH FOOTING UNKNOWN, STRINGERS NOT BOLTED TO SUPPORTS, 2X4 USED TO SUPPORT STRINGERS, 2X8 JOIST OVER SPANNED LEDGERBOARDS NOT BOLTED, MISSING JOIST HANGERS, RAILINGS TOO LOW AND NOT BOLTED TO BUILDING, IMPROPER BEAM TO COLUMN CONNECTION NO ANGLE BRACKETS, 6X6 COLUMN WITH FIRECUT AT LAP JOINT 4X4 COLUMN NOT BOLTED AT LAP JOINT PLANS AND PERMIT REQUIRED. | 6045 N TALMAN AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | SOUTH ELEVATION VERTICAL FRACTURES 1ST TO 2ND. | 6045 N TALMAN AVE | PERIODIC | FAILED | View |
REPAIR WINDOW SILLS | SOUTH ELEVATION WINDOW SILLS WITH OPEN MORTAR JOINTS. | 6045 N TALMAN AVE | PERIODIC | FAILED | View |
CARB MONOX DETECT IN RESID | LAUNDRY ROOM NO CARBON MONOXIDE DETECTOR. | 6045 N TALMAN AVE | PERIODIC | FAILED | View |
INSTALL SMOKE DETECTORS | LAUNDRY ROOM NO SMOKE DETECTOR | 6045 N TALMAN AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO MEET DWELLING UNITS TO VERIFY DETECTORS OR ACCESS OR NORTHEAST PORCH. | 6045 N TALMAN AVE | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | (SR#07-02420320) BUILDING NOT REGISTERED FROM 2005 THRU 2008 | 6045 N TALMAN AVE | PERIODIC | FAILED | View |
INSPECT CONSTRUCTION WORK | PLANS AND PERMIT FOR PORCH REPAIRS NOT AVAILABLE FOR INSPECTOR'S REVIEW AT TIME OF INSPECTION | 6045 N TALMAN AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO INTERIORS TO CHECK DETECTORS, NO ACCESS/ ENTRY TO REAR PORCHES. | 6045 N TALMAN AVE | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING/ OWNERS ID SIGN- MISSING. | 6045 N TALMAN AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | NORTH ELEVATION/ REAR EXTERIOR 3 STORY PORCH/ STAIR HEADER BEAMS- WEAK, SAGGING, AND FASTENED TO COLUMNS WITH TOE NAILS ONLY. WINDER STRINGERS- FASTENED WITH MENDING PLATES AND NAILED ONLY [WEAK, AND SAGGING]. TREADS- ROTTING. ALL COLUMNS AND BEAMS HAVE SCABBED SECTIONS. PLANS AND PERMIT REQUIRED FOR ALL REPAIRS TO: NORTH ELEVATION/ REAR EXTERIOR 3 STORY PORCH. | 6045 N TALMAN AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | MOST APARTMENTS- NO RESPONSE, UNVERIFIED DETECTORS,. AND CONDITIONS. UNABLE TO INSPECT SOME INTERIOR STAIRWAYS. UNVERIFIED COMPLAINT OF: ROOF LEAKING, AND MOLD. | 6045 N TALMAN AVE | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | BUILDING NOT REGISTERED FROM 2008 THRU 2014. | 6045 N TALMAN AVE | PERIODIC | FAILED | View |
ARRANGE FOR REINSPECTION REGAR | INTERIOR OF BUILDING MOST APARTMENTS NO RESPONSE. UNVERIFIED DETECTORS AND CONDITIONS. | 6045 N TALMAN AVE | PERIODIC | FAILED | View |