Chicago Building Violations Data: 64 Violations
Violation Inspector Comments Address Category Status View
OBTAIN OR POST PERMIT 8830 S EXCHANGE AVE COMPLAINT CLOSED View
MAINTAN BLDG IN SAFE CONDITION 8830 S EXCHANGE AVE COMPLAINT CLOSED View
REPAIR/WRECK DANGER RESID PREM 8830 S EXCHANGE AVE COMPLAINT CLOSED View
WATCHMAN 8830 S EXCHANGE AVE COMPLAINT CLOSED View
VACANT BUILDING - REGISTER 8830 S EXCHANGE AVE COMPLAINT CLOSED View
POST OWNER INFO ON ABDN BLDG 8830 S EXCHANGE AVE COMPLAINT CLOSED View
PROVIDE PERMIT(S) TO CORRECT VIOLATIONS. (13-12-360) 8830 S EXCHANGE AVE COMPLAINT FAILED View
EXPOSED WIRING REMOVE OPEN WIRING AND OPEN AIR SPLICES THROUGHOUT BASEMENT AND WHERE REQUIRED THROUGHOUT PREMISES - DANGEROUS AND HAZARDOUS. 8830 S EXCHANGE AVE COMPLAINT FAILED View
WORK NOT ALLOWED REAR OF PROPERTY WOOD PICKET FENCE OVER 5 FT. REMOVE, REDUCE HEIGHT OR OBTAIN PERMIT TO STAND AS IS. 8830 S EXCHANGE AVE COMPLAINT FAILED View
REPLACE D&H PORCH REAR OF PROPERTY OPEN WOOD PORCH POSTED AS DANGEROUS AND HAZARDOUS. 1) ROTTED TREADS; 2) UNEVEN RISERS; 3). STAIRS IMPROPERLY PITCHED; 4). STRINGER NAILED ONLY; 5). MISSING JOIST HANGERS; 6). STAIRS RESTED ON 4X4 POST, NO FOOTING; 7). STRINGER BROKEN, FRACTURED CAUSING IMMEDIATE DANGER WHEN ACCESSED. 8830 S EXCHANGE AVE COMPLAINT FAILED View
PLANS & PERMITS REQ - CONTRCTR PLANS AND PERMITS REQUIRED FOR ALL REPAIRS TO REAR OPEN PORCH, BUT NOT LIMITED TO ALL REPAIRS THROUGHOUT PROPERTY TO CORRECT ALL BUILDING CODE VIOLATIONS. OBTAIN FULL PLANS AND PERMITS REQUIRED FOR ENTIRE PROPERTY. CURRENTLY 2 DWELLING UNIT CONVERSION AT 1ST FLOOR: 1-FRONT, 3 BEDROOM, 1 KITCHEN, 1 BATHROOM; 1-REAR, 2 BEDROOM, 1 BATHROOM, 1 KITCHEN. NO PLANS OR PERMIT FOR CURRENT CONDITIONS. 8830 S EXCHANGE AVE COMPLAINT FAILED View
REPAIR/REBUILD GARAGE OR SHED REAR OF PROPERTY GARAGE REPAIRS REQUIRED: 1). GARAGE WINDOWS BOARDED; 2). GARAGE ROOF SHINGLES BUCKLING; 3). ROTTED FASCIA BOARDS. UNABLE TO DETERMINE INTERIOR CONDITIONS. 8830 S EXCHANGE AVE COMPLAINT FAILED View
REPAIR LINTELS RUSTED LINTELS SOUTH ELEVATION REPAIR ALL FAILING LINTELS THROUGHOUT PROPERTY. 8830 S EXCHANGE AVE COMPLAINT FAILED View
PROVIDE GUARD RAIL 42 IN HIGH GUARDRAIL LOOSE AT SOUTH ELEVATION SERVICE WALK AREA. 8830 S EXCHANGE AVE COMPLAINT FAILED View
REPAIR EXTERIOR WALL WASHED OUT MORTAR, SPALLING BRICK AT NORTH AND SOUTH ELEVATIONS. 8830 S EXCHANGE AVE COMPLAINT FAILED View
REPLCE WINDOW PANES, PLEXGLAS BOARDED BASEMENT WINDOWS WITH PLYWOOD MATERIAL. REMOVE AND REPAIR WINDOWS WHERE NEEDED. 8830 S EXCHANGE AVE COMPLAINT FAILED View
REPAIR EXTERIOR STAIR EXTERIOR STAIR SYSTEM LOCATED AT THE SOUTH ELEVATION SERVICE WALK AREA. 1). UNEVEN RISERS; 2). TREADS LOOSE UPON LIVE LOADS; 3). STRINGER PULLING AWAY FROM PROPERTY; 4).ALL CONNECTIONS NAILED ONLY. 8830 S EXCHANGE AVE COMPLAINT FAILED View
REPAIR EXTERIOR DOOR REAR OF PROPERTY (1 REAR) EXTERIOR DOOR BROKEN AT STRIKE AND ROTTED, REPLACEMENT REQUIRED. 8830 S EXCHANGE AVE COMPLAINT FAILED View
INSTALL SMOKE DETECTORS MISSING SMOKE DETECTORS THROUGHOUT PROPERTY - DANGEROUS AND HAZARDOUS. 8830 S EXCHANGE AVE COMPLAINT FAILED View
CARB MONOX DETECT IN RESID MISSING CARBON MONOXIDE DETECTORS THROUGHOUT PROPERTY - DANGEROUS AND HAZARDOUS. 8830 S EXCHANGE AVE COMPLAINT FAILED View
MICE/RODENTS MICE/RODENT INFESTATION THROUGHOUT PROPERTY, EXTERMINATOR REQUIRED. 8830 S EXCHANGE AVE COMPLAINT FAILED View
SUBMIT STRUCT. ENG. RPT (INT.) KNOTCHED FLOOR JOISTS THROUGHOUT BASEMENT AREA, MISSING SECTIONS OF SUB FLOORING MATERIAL BELOW BATHROOM AREA. 8830 S EXCHANGE AVE COMPLAINT FAILED View
CEMENT BASEMENT FLOOR CEMENT BASEMENT FLOOR AT CRAWL SPACE FRONT SECTION OF PROPERTY TO PREVENT RAT INFESTATION AND RAT BURROUGHING. 8830 S EXCHANGE AVE COMPLAINT FAILED View
RATS RAT INFESTATION THROUGHOUT PROPERTY. VISIBLE RAT DROPPINGS IN BASEMENT AREA. RAT PROOFING REQUIRED. 8830 S EXCHANGE AVE COMPLAINT FAILED View
CONNECT GAS APPLIANCE TO VENT FLEX LINE FOR GAS OPERATED DRYER BEING VENTED INTO BASEMENT AND NOT CONNECTED TO AN OUTSIDE VENT. 8830 S EXCHANGE AVE COMPLAINT FAILED View
PROPER MATRL WATER SUPPLY PIPE UNAPPROVED FLEXIBLE WATER SUPPLY PIPING TO BATHROOM TOILETS, LAVATORIES AND KITCHEN SINKS THROUGHOUT PREMISES. 8830 S EXCHANGE AVE COMPLAINT FAILED View
PROVIDE TRAP FOR FIXTURE MISSING TRAP AT REAR UNIT SHOWER EXPOSING PREMISES TO DANGEROUS AND HAZARDOUS SEWER GAS. 8830 S EXCHANGE AVE COMPLAINT FAILED View
STOP ODORS RPR DFT SEWAGE SYS OPEN SEWERS THROUGHOUT BASEMENT AREA EXPOSING PREMISES TO DANGEROUS AND HAZARDOUS SEWER GAS. 8830 S EXCHANGE AVE COMPLAINT FAILED View
PRV FLUE FOR HOT WATER HEATER BACKPITCHED FLUE PIPING TO WATER HEATER AT BASEMENT ELEVATION EXPOSING PREMISES TO DANGEROUS AND HAZARDOUS CARBON MONOXIDE GAS. 8830 S EXCHANGE AVE COMPLAINT FAILED View
SOIL/WASTE,VENT PIPE MATRL UNAPPROVED PVC UNDERGROUND DRAINAGE PIPING THROUGHOUT BASEMENT AREA. UNAPPROVED CORRUGATED PVC DRAINAGE TUBULAR PIPING IN 1ST FLOOR FRONT UNIT BATHROOM LAVATORY AND KITCHEN SINK. 8830 S EXCHANGE AVE COMPLAINT FAILED View
REPLACE DEFECTIVE FAUCET LEAKING BATHROOM LAVATORY FAUCETS, KITCHEN SINKS AND SHOWER VALVES THROUGHOUT PREMISES. 8830 S EXCHANGE AVE COMPLAINT FAILED View
REPLACE DEFECTIVE SOIL PIPING REAR BATHROOM LAVATORY NOT DRAINING WATER DUE TO BLOCKAGE IN DRAIN. 8830 S EXCHANGE AVE COMPLAINT FAILED View
REPLACE DEFECTIVE PLBG FIXTURE MISSING FLUSH HANDLE AT REAR UNIT BATHROOM TOILET. 8830 S EXCHANGE AVE COMPLAINT FAILED View
SUBMIT PLANS FOR PLUMBING PRMT SUBMIT PLANS TO BUILDING, SEWER AND WATER DEPARTMENTS FOR APPROVAL AND PERMIT BEFORE CONSTRUCTING, ALTERING OR USING PLUMBING SYSTEM. SPECIFICALLY ENTIRE PLUMBING SYSTEM WAS CONSTRUCTED WITHOUT PLANS OR PERMITS. 8830 S EXCHANGE AVE COMPLAINT FAILED View
ENGAG LIC & BOND PLMBNG CNTRC ENGAGE LICENSED AND BONDED PLUMBING CONTRACTOR TO INSTALL PLUMBING. 8830 S EXCHANGE AVE COMPLAINT FAILED View
DEFECTIVE SERVICE HAPHAZARDLY INSTALLED ELECTRICAL SERVICE. SERVICE RISER CONDUCTORS APPEAR UNDERSIZED. UNAPPROVED RISER SUPPORTS. LOOSE SERVICE RISER CONDUCTOR TERMINATIONS AT METER ENCLOSURE. GREEN WIRE BEING USED AS SERVICE CONDUCTOR IN RISER. DAMAGED HAPHAZARDLY INSTALLED MAIN DISCONNECTS. DANGEROUS AND HAZARDOUS. 8830 S EXCHANGE AVE COMPLAINT FAILED View
PROPER SIZE GRD ELECTRODE COND SERVICE NOT GROUNDED - DANGEROUS AND HAZARDOUS. 8830 S EXCHANGE AVE COMPLAINT FAILED View
DEFECTIVE METER EQUIPMENT DAMAGED METER ENCLOSURE. MISSING METER COVERS. JUMPED METERS. DANGEROUS AND HAZARDOUS. 8830 S EXCHANGE AVE COMPLAINT FAILED View
DEFECTIVE DISTRIBUTION DAMAGED PANELS. PANEL COVERS MISSING. PANELS INSTALLED UPSIDE DOWN. LOOSE CONDUCTOR TERMINATIONS. DANGEROUS AND HAZARDOUS. 8830 S EXCHANGE AVE COMPLAINT FAILED View
NO PERMIT WIRING NEW SERVICE INSTALLED WITHOUT PERMIT. 8830 S EXCHANGE AVE COMPLAINT FAILED View
CONTINUITY OF RACEWAYS REPAIR RACEWAYS PULLED APART AT FITTINGS, RACEWAYS PULLED AWAY FROM BOXES, RACEWAYS NOT CONNECTED TO PANELS, OPEN AIR SPLICES BETWEEN PIECES OF FLEXIBLE METAL CONDUIT THROUGHOUT BASEMENT AND AT REAR EXTERIOR AND ENSURE GROUND CONTINUITY WHERE REQUIRED THROUGHOUT PREMISES. DANGEROUS AND HAZARDOUS. 8830 S EXCHANGE AVE COMPLAINT FAILED View
INSTALL COVERS CLOSE OPEN BOXES VARIOUS LOCATIONS BASEMENT AND WHERE REQUIRED THROUGHOUT PREMISES - DANGEROUS AND HAZARDOUS. 8830 S EXCHANGE AVE COMPLAINT FAILED View
ARMORED CABLE REMOVE UNAPPROVED, BROKEN, CORRODED ARMORED CABLE VARIOUS LOCATIONS BASEMENT AND WHERE REQUIRED THROUGHOUT PREMISES. DANGEROUS AND HAZARDOUS. 8830 S EXCHANGE AVE COMPLAINT FAILED View
SECURE RACEWAY SECURE UNSUPPORTED RACEWAYS IN BASEMENT AND WHERE REQUIRED THROUGHOUT PREMISES. 8830 S EXCHANGE AVE COMPLAINT FAILED View
SUPPORT OUTLET AND BOX SECURE UNSUPPORTED BOXES VARIOUS LOCATIONS BASEMENT AND WHERE REQUIRED THROUGHOUT PREMISES. 8830 S EXCHANGE AVE COMPLAINT FAILED View
SEE INSPECTOR COMMENTS REMOVE UNAPPROVED FLEXIBLE METAL CONDUIT THROUGHOUT BASEMENT AND WHERE REQUIRED THROUGHOUT PREMISES - DANGEROUS AND HAZARDOUS. (14E-3-348.12) 8830 S EXCHANGE AVE COMPLAINT FAILED View
ALL EXTERIOR LIGHT FIXTURES, BOXES, FITTINGS, RACEWAYS, DEVICES MUST BE SUITABLE FOR WET LOCATION. (14E-1-110.3) 8830 S EXCHANGE AVE COMPLAINT FAILED View
ACCESS TO JBS PROVIDE ACCESS TO BURIED AND/OR PARTIALLY BURIED BOXES IN CENTER INTERIOR STAIRWELL, APARTMENT 1R BEDROOM AND WHERE REQUIRED THROUGHOUT PREMISES. 8830 S EXCHANGE AVE COMPLAINT FAILED View
EXPOSED WIRING FIXTURES REPAIR LIGHT FIXTURE HANGING FROM BOX BY WIRES AT TOP OF MIDDLE INTERIOR STAIRS, OPEN WIRES AT LIGHT FIXTURES IN BASEMENT AND REMOVE/REPAIR OPEN WIRE AT LIGHT FIXTURES WHERE REQUIRED THROUGHOUT PREMISES. DANGEROUS AND HAZARDOUS. 8830 S EXCHANGE AVE COMPLAINT FAILED View
DETERIORATED CONDUCTORS REPLACE DAMAGED WIRING AT PANELS, DETERIORATED WIRE VISIBLE AT LOCATIONS IN BASEMENT AND REPLACE DAMAGED/DETERIORATED WIRING WHERE REQUIRED THROUGHOUT PREMISES - DANGEROUS AND HAZARDOUS. 8830 S EXCHANGE AVE COMPLAINT FAILED View
DEFECTIVE OUTLETS REPLACE DAMAGED/BURIED RECEPTACLE IN APARTMENT 1R KITCHEN, VARIOUS LOCATIONS BASEMENT AND REPLACE DAMAGED/BROKEN DEVICES WHERE REQUIRED THROUGHOUT PREMISES. 8830 S EXCHANGE AVE COMPLAINT FAILED View
DEFECTIVE FIXTURES INSTALL GLOBES AND REPLACE DAMAGED LIGHT FIXTURES IN APARTMENT 1R, VARIOUS LOCATIONS BASEMENT AND WHERE REQUIRED THROUGHOUT PREMISES. 8830 S EXCHANGE AVE COMPLAINT FAILED View
CORRODED CONDUIT & EQUIP REPLACE CORRODED RACEWAYS, BOXES, EQUIPMENT THROUGHOUT BASEMENT AND WHERE REQUIRED THROUGHOUT PREMISES. 8830 S EXCHANGE AVE COMPLAINT FAILED View
ABANDONED EQUIPMENT REPLACE ABANDONED RACEWAY, BOXES, EQUIPMENT THROUGHOUT BASEMENT AND WHERE REQUIRED THROUGHOUT PREMISES. 8830 S EXCHANGE AVE COMPLAINT FAILED View
ADD RECEPTACLES ADD RECEPTACLES TO EASE CORD USAGE IN APARTMENT 1R, 2R AND WHERE REQUIRED THROUGHOUT PREMISES. 8830 S EXCHANGE AVE COMPLAINT FAILED View
ADD BRANCH CIRCUITS ADD CIRCUITS TO PREVENT OVERLOAD IN APARTMENT 1R, 2R AND WHERE REQUIRED THROUGHOUT PREMISES - DANGEROUS AND HAZARDOUS. 8830 S EXCHANGE AVE COMPLAINT FAILED View
REMOVE EXPOSED CABLE REMOVE UNAPPROVED OPEN AIR SPLICED NM CABLE (ROMEX) THROUGHOUT BASEMENT AND WHERE REQUIRED THROUGHOUT ENTIRE PREMISES - DANGEROUS AND HAZARDOUS. 8830 S EXCHANGE AVE COMPLAINT FAILED View
PROVIDE PERMIT TO REPAIR WATER DAMAGED ELECTRICAL RACEWAYS, BOXES, WIRE, EQUIPMENT AT CENTER BASEMENT AREA AND WHERE REQUIRED THROUGHOUT PREMISES - DANGEROUS AND HAZARDOUS. (13-12-360) 8830 S EXCHANGE AVE COMPLAINT FAILED View
PROVIDE PERMIT FOR THE INSTALLATION OF ELECTRICAL CONDUIT, BOXES, WIRE, DEVICES AND EQUIPMENT INSTALLED THROUGHOUT 1ST FLOOR AND BASEMENT. NEW SERVICE - NO PERMITS. NEW RACEWAYS, FIXTURES, BOXES, WIRING THROUGHOUT BASEMENT EXTENDING INTO FIRST FLOOR AREAS - NO PERMITS. NEW FIXTURES THROUGHOUT 1ST FLOOR AREAS - NO PERMITS. (13-12-360) 8830 S EXCHANGE AVE COMPLAINT FAILED View
PROVIDE REQUIRED ROUGH INSPECTIONS FOR THE INSTALLATION OF ELECTRICAL CONDUIT, BOXES, WIRE, DEVICES AND EQUIPMENT INSTALLED THROUGHOUT 1ST FLOOR AND BASEMENT. NEW SERVICE - NO PERMITS. NEW RACEWAYS, FIXTURES, BOXES, WIRING THROUGHOUT BASEMENT EXTENDING INTO FIRST FLOOR AREAS - NO PERMITS. NEW FIXTURES THROUGHOUT 1ST FLOOR AREAS - NO PERMITS. (13-12-380) 8830 S EXCHANGE AVE COMPLAINT FAILED View
STOP LEAKING WATER WATER LEAKING THROUGHOUT BASEMENT. 8830 S EXCHANGE AVE COMPLAINT FAILED View
REMOVE UNAPPROVED FLOOR RECEPTACLE IN APARTMENT 1R BEDROOM AND WHERE REQUIRED THROUGHOUT - DANGEROUS AND HAZARDOUS. (14E-4-406.4) 8830 S EXCHANGE AVE COMPLAINT FAILED View
SERVICE WALK, PASSAGE, AREAWAY ELEVATED WOODEN SERVICE WALK LOCATED AT THE SOUTH ELEVATION MISSING BOARDS, UNEVEN, CAUSING TRIP HAZARDS. 8830 S EXCHANGE AVE COMPLAINT FAILED View
INSTALL ILLUMINATION INSTALL OPERABLE ILLUMINATION AT ALL EXTERIOR ENTRIES AND GARAGE ENTRY. 8830 S EXCHANGE AVE COMPLAINT FAILED View