Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-23 @ 6:38 AM
PIN: 20081150090000
Property Address: 4817 S ELIZABETH ST
City - Zip: CHICAGO - 60609
2023 Property Class: 205
2023 Township: 72 - Lake
2023 Neighborhood: 72051
2023 Tax District: 72018
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 17 Violations
Violation Inspector Comments Address Category Status View
CARB MONOX DETECT IN RESID 1ST FLOOR APT., CARBON MONOXIDE DETECTOR - MISSING BATTERY. 4817 S ELIZABETH ST COMPLAINT FAILED View
REPAIR/REPLACE SMOKE DETECTORS 1ST FLOOR APT. SMOKE DETECTOR - MISSING BATTERY AND WAS ON TOP OF FURNITURE. 4817 S ELIZABETH ST COMPLAINT FAILED View
SCREEN OUTER DOORS, WINDOWS NORTH ELEVATION / 2ND FLOOR - MISSING WINDOW SCREEN. 4817 S ELIZABETH ST COMPLAINT PASSED View
POST OWNER/MANAGERS NAME/# BUILDING OWNER'S IDENTIFICATION SIGN MISSING. 4817 S ELIZABETH ST COMPLAINT PASSED View
CHIMNEY CAPPING CHIMNEY / CAPPING - MISSING. 4817 S ELIZABETH ST COMPLAINT PASSED View
REPAIR EXTERIOR DOOR WEST ELEVATION / COMMON ENTRY DOOR - DELAMINATING. 4817 S ELIZABETH ST COMPLAINT PASSED View
INSTALL SMOKE DETECTORS 2ND FLOOR APARTMENT AND TOP OF INTERIOR STAIRWAY - SMOKE DETECTOR MISSING. 4817 S ELIZABETH ST COMPLAINT PASSED View
CARB MONOX DETECT IN RESID 2ND FLOOR APARTMENT - CARBON MONOXIDE DETECTOR MISSING. 4817 S ELIZABETH ST COMPLAINT PASSED View
OBSTRUCTIONS IN EXIT WAY 1ST AND 2ND FLOOR APARTMENTS / PRIMARY AND SECONDARY EGRESS - BURGLAR GATES. 4817 S ELIZABETH ST COMPLAINT PASSED View
REPAIR FLOOR 2ND FLOOR APARTMENT - UNEVEN FLOOR THROUGHOUT. 4817 S ELIZABETH ST COMPLAINT PASSED View
DWELLING CLEAN AND SANITARY 2ND FLOOR APARTMENT - UNSANITARY CONDITIONS THROUGHOUT. 4817 S ELIZABETH ST COMPLAINT PASSED View
CUT OR REMOVE HIGH WEEDS REAR YARD - HIGH WEEDS THROUGHOUT. 4817 S ELIZABETH ST COMPLAINT PASSED View
PRV CAST IRON COVER FOR BASIN REAR YARD / CATCH BASING - MISSING CAST IRON COVER. 4817 S ELIZABETH ST COMPLAINT PASSED View
CONNECT DOWNSPOUT TO SEWER NORTH AND SOUTH ELEVATIONS / DOWNSPOUTS - NOT CONNECTED TO SEWER. 4817 S ELIZABETH ST COMPLAINT PASSED View
REPLACE D&H PORCH WEST ELEVATION / 2 STORY OPEN WOOD PORCH - DANGEROUS AND HAZARDOUS - (2)4X6 POSTS ON SOIL, WITH NO FOUNDATION. (2) 4X6 POSTS ON CONCERETE PIER, FOUNDATION STATUS UNKNOWN. 4X6 POST SUPPORTING 1ST FLOOR EXTERIOR STAIR AND 2ND FLOOR LANDING ROTTING AND MISSING SECTION AT 30 INCHES ABOVE GRADE. UPPER AND LOWER SECTIONS OF STRINGER INADEQUATELY ANCHORED TO POSTS, BEAMS AND EXTERIOR WALL WITH NAILS ONLY. LOOSE AND PULLING RAILINGS THROUGHOUT. LADDER TYPE RAILING SYSTEM AT LANDING GUARDRAILS WITH HORIZONTAL TIES SPACED 6 INCHES APART. 2ND FLOOR STAIR FLIGHT SHIFTING TOWARDS EAST. PORCH SYSTEM SWAYS WITH LIVE LOAD. STAIR RAILINGS AT HEIGHT OF ONLY 24 INCHES THROUGHOUT, GUARDRAILINGS AT HEIGHT OF ONLY 30 INCHES THROUGHOUT. UNEVEN RISERS THROUGHOUT RANGING IN SIZE FROM 4 INCHES TO 7 INCHES. ROTTING FLOORBOARDS, TREADS, RISERS AND RAILING THROUGHOUT.PLANS AND PERMIT REQUIRED FOR 2 STORY OPEN WOOD PORCH REPLACEMENT. 4817 S ELIZABETH ST COMPLAINT PASSED View
REPAIR EXTERIOR STAIR EAST ELEVATION / 1 STORY EXTERIOR STAIR - DANGEROUS AND HAZARDOUS - (2) 4X6 POSTS ON CONCERETE PIER, FOUNDATION STATUS UNKNOWN. 4X6 POST SUPPORTING 1ST FLOOR EXTERIOR STAIR AND 2ND FLOOR LANDING ROTTING AND MISSING SECTION AT 30 INCHES ABOVE GRADE. UPPER AND LOWER SECTIONS OF STRINGER INADEQUATELY ANCHORED TO POSTS WITH NAILS ONLY. LOOSE AND PULLING RAILINGS THROUGHOUT. RAILING SYSTEM AT HEIGHT OF ONLY 30 INCHES THROUGHOUT. ROTTING FLOORBOARDS, TREADS, RISERS AND RAILING THROUGHOUT.PLANS AND PERMIT REQUIRED FOR 1 STORY EXTERIOR STAIR REPLACEMENT. 4817 S ELIZABETH ST COMPLAINT PASSED View
ARRANGE PREMISE INSPECTION 1ST FLOOR APARTMENT, NO RESPONSE. UNABLE TO VERIFY DETECTORS, CONDITIONS AND OCCUPANCY. 4817 S ELIZABETH ST COMPLAINT PASSED View