Last Modification Date: 2024-08-30 @ 4:41 PM
PIN: 16043270160000
Property Address: 5415 W RICE ST
City - Zip: CHICAGO - 60651
2023 Property Class: 203
2023 Township: 77 - West Chicago
2023 Neighborhood: 77013
2023 Tax District: 77001
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 110 Violations
Violation Inspector Comments Address Category Status View
SAFE WORKING CONDITIONS BOILER NOT WORKING, GAS SHUT OFF. RADIATORS MISSING IN 1ST AND 2ND FLOOR APARTMENTS. 5415 W RICE ST COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION INTERIOR OF BUILDING,NO RESPONSE,UNVERIFIED DETECTORS. 5415 W RICE ST COMPLAINT FAILED View
REPAIR EXTERIOR PLATFORM FRONT WOOD RAMP - UNEVEN SECTION. 5415 W RICE ST COMPLAINT FAILED View
REPAIR EAVES WEST ROOF EAVES - LOOSE SOFFIT BOARDS. 5415 W RICE ST COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# BUILDING - MISSING OWNER'S ID. SIGN. 5415 W RICE ST COMPLAINT FAILED View
COVER OUTLETS AND JBS BASEMENT - OPEN JUNCTION BOXES WITH EXPOSED WIRES; COVERS MISSING 5415 W RICE ST COMPLAINT FAILED View
EXPOSED WIRING BASEMENT - OPEN JUNCTION BOXES WITH EXPOSED WIRES; COVERS MISSING 5415 W RICE ST COMPLAINT FAILED View
SUBMIT 2 COPY STRUCTURAL RPT MAIN WOOD SUPPORT BEAM FOR BUILDING, AT FOUNDATIONS WALL SOUTH ELEVATION, AT THE POCKET AREA, HAS ROOTED SECTION OF MAIN WOODEN BEAM. THE BEAM HAS BEEN SPLICED AND SHORED UP WITH A 2X4 WEDGED ON TOP OF FOUNDATION WALL. PROVIDE STRUCTURAL ENGINEERS REPORT ON STABILITY OF MAIN BEAM AND SUGGESTED REPAIRS. 5415 W RICE ST COMPLAINT FAILED View
INTERIOR FINISH FIRERESISTANCE REAR ENCLOSED PORCH SYSTEM, FROM GRADE TO SECOND FLOOR, WALL COVERED WITH UNFIRED RATED MATERIAL, INCLUDING STRIPS OF CARPETING, LUAN WOOD STRIPS, PLYWOOD, DRYWALL INSTALLED BACKWARDS EXPOSING THE PAPER BACKING, 5415 W RICE ST COMPLAINT FAILED View
REPLCE WINDOW PANES, PLEXGLAS BASEMENT - GLASS BLOCK WINDOW OUT OF PLUMB; LEANING; GAPS AROUND FRAME/OPENING 5415 W RICE ST COMPLAINT FAILED View
REMOVE STAGNANT WATER BSMT REPAIR BROKEN SEWER NEAR EAST WALL.(13-196-580A) (7-28-060) (11-16-020) 5415 W RICE ST COMPLAINT FAILED View
REPAIR DEFECTIVE DOWNSPOUT EAST GUTTER AND CONNECT TO SEWER SYSTEM.(18-29-1101.2.1) (7-28-060) 5415 W RICE ST COMPLAINT FAILED View
PROVIDE A FLOOR DRAIN IN WATER HEATER AREA.(18-29-501.3) 5415 W RICE ST COMPLAINT FAILED View
REMV OBSTR FROM DRAINAGE SYSTM FIRST FLOOR LAVATORY. (11-16-020) (13-168-120) 5415 W RICE ST COMPLAINT FAILED View
PROPER MATERIAL FOR HSE DRAIN REMOVE ALL PVC PIPE FROM BELOW GRADE IN BASEMENT.(13-168-480) (13-168-490) (18-29-702.2) 5415 W RICE ST COMPLAINT FAILED View
REPL DEFECTIVE BATHROOM FLOOR FIRST AND SECOND FLOOR TILE MISSING IN BATHROOMS 5415 W RICE ST COMPLAINT FAILED View
PROPER MATRL WATER SUPPLY PIPE REMOVE ALL FLEX AND PVC WATERSUPPLIES FROM LAVATORIES, KITCHEN SINKS, AND WATER CLOSETS THROUGH OUT BUILDING. REMOVE METAL CLAMP ON WATER SERVICE FRONT LOCATION. REMOVE PVC PIPE ON WATER HEATER RELIEF VALVE. (11-8-570) (18-29-605.4 THRU 9) 5415 W RICE ST COMPLAINT FAILED View
PERMIT REQUIRED FIRST FLOOR HAS PARTITION INSTALLED FULL LENGTH OF LIVING ROOM SEPARATING THE STAIRWAY FROM LIVING ROOM / REST OF FIRST FLOOR. PARTITION INSTALLED NEAR THE TOP OF STAIRWAY, WITH DOOR, CREATING SEPARATE UNITS ON SECOND FLOOR 5415 W RICE ST COMPLAINT FAILED View
VENT SYSTEM TO PRVNT BACK PRES SECOND FLOOR KITCHEN SINK. (13-168-790) (18-29-901.2) 5415 W RICE ST COMPLAINT FAILED View
UNAPPROVED HEATING DEVICE TENANTS USING ELECTRIC PORTABLE SPACE HEATERS FOR HEATING SOURCE 5415 W RICE ST COMPLAINT FAILED View
PRV WATER PIPES PROPER SIZE A 3/4 INCH WATER SUPPLY PIPE IS REQUIRED FOR WATER HEATER INLET AND OUTLET 5415 W RICE ST COMPLAINT FAILED View
OBTAIN OR POST PERMIT ORIGINALLY A SINGLE FAMILYBHOME, FIRSTBAND SECOND FLOORS HAVE BEEN ALTERED. FIRST FLOOR HAS BEEN WALLED OFF FROM SECOND FLOOR, SECOND FLOOR HAS BBEN WALLED OFF FROM FRONT STAIRWAY. FLOORS HAVE BEEN RAZED AND CHANGED IN BATHROOM AND FRONT ENTRY BEDROOM. PLANS AND PERMITS REQUIRED FOR ALTERATIONS OR TO BRING TO ORIGINAL STATE. 5415 W RICE ST COMPLAINT FAILED View
STOP LEAKING WATER FIRST FLOOR CEILING IN DINING ROOM, SECOND FLOOR BATHTUB. ALSO, SEAL WALLS, FIRST FLOOR KITCHEN SINK.(18-29-705.1 THRU 10) (13-168-120) (13-168-1480) 5415 W RICE ST COMPLAINT FAILED View
REPAIR CATCH BASIN SINKING ON ONE (1) SIDE. (13-168-1280) (18-29-1003.1 THRU 3) 5415 W RICE ST COMPLAINT FAILED View
PRV WATER PIPES PROPER SIZE (18-29-502.1) 3/4 PIPE REQUIRED FOR WATER HEATER INLET AND OUTLET. (11-8-540) 5415 W RICE ST COMPLAINT FAILED View
REPLACE DEFECTIVE FAUCET SECOND FLOOR BATHTUB - HANDLE AND SLEEVE MISSING. ALSO FLANGES. (13-168-120) (18-29-102.3) 5415 W RICE ST COMPLAINT FAILED View
REPL DEFECTIVE BATHROOM FLOOR FIRST AND SECOND FLOOR TILE MISSING. (18-29-405.2.1)(13-196-540F) 5415 W RICE ST COMPLAINT FAILED View
REPLACE DEFECTIVE PLBG FIXTURE FIRST FLOOR KITCHEN SINK HAS ROTTED WOOD, SECOND FLOOR SINK HAS NO BASE, BOTH FLOORS NEED REFINISHING OR REPLACEMENT OF BATHTUBS, AS THEY HAVE WORN PORCELAIN ARE ARE RUSTED 5415 W RICE ST COMPLAINT FAILED View
REPLACE DEFECTIVE PLBG FIXTURE FIRST FLOOR KITCHEN SINK, WOOD ROTTED. SECOND FLOOR KITCHEN SINK HAS NO BASE! BOTH FLOORS, TUBS MUST BE REFINISHED OR REPLACED - WORN PORCELAIN AND RUST 5415 W RICE ST COMPLAINT FAILED View
OBTN PERMIT FOR PLUMBING WORK (18-29-106.1) (13-168-070) 5415 W RICE ST COMPLAINT FAILED View
REPLACE DEFECTIVE FAUCET SECOND FLOOR BATHUB'S HANDLE, SLEEVE AND FLANGES MISSING 5415 W RICE ST COMPLAINT FAILED View
LICENSED BONDED PLMBG CONTRCTR 1(4-332-010-100 (18-29-106.2) (13-168-070) 5415 W RICE ST COMPLAINT FAILED View
REPAIR DOOR, INT. FIRST FLOOR BEDROOM DOOR HAS LARGE HOLES IN THE DOOR 5415 W RICE ST COMPLAINT FAILED View
HEAT UNIT ADEQUATELY APT. #1-ROOM TEMP. LIVING ROOM 63F., BEDROOM 59F., KITCHEN 61F. AT 2:23PM.APT. #2- ROOM TEMP. BEDROOM 1-61F., BEDROOM #2 61F., KITCHEN 61F. AT 2:14PM.HEATING SYSTEM IS OFF AT TIME OF INSPECTION,NO HEAT PROVIDED.GAS SERVICE IS SHUT OFF . 5415 W RICE ST COMPLAINT FAILED View
SUPPLY HOT WTR MIN TEMP 120DEG APT. #1AND APT. #2HOT WATER SUPPLIED AT ONLY 60F.GAS SERCICE-SHUT OFF,NO HOT WATER FURNISHED. 5415 W RICE ST COMPLAINT FAILED View
INSTALL SMOKE DETECTORS FRONT AND REAR STAIRWAYS- MISSING SMOKE DETECTORS. 5415 W RICE ST COMPLAINT FAILED View
INSTALL SMOKE DETECTORS FRONT AND REAR STAIRWAYS MISSING SMOKE DETECTORS. 5415 W RICE ST COMPLAINT FAILED View
LICENSED BONDED PLMBG CONTRCTR NO PLUMBER OF RECORD FOR ANY INSTALLATION OR REPAIRS 5415 W RICE ST COMPLAINT FAILED View
OBTN PERMIT FOR PLUMBING WORK OBTAIN PERMIT FOR PLUMBING WORK BEFORE UNDERTACKING WORK, NO PLUMBING PERMIT ON FILE 5415 W RICE ST COMPLAINT FAILED View
REPAIR EAVES EAST, SOUTH, NORTH ELEVATIONS - EAVES - PAINT PEELING; HOLE AT SOFFIT (NORTH) 5415 W RICE ST COMPLAINT FAILED View
REPAIR SCREENS WINDOW SCREENS - TORN 5415 W RICE ST COMPLAINT FAILED View
RAT STOP AROUND EXTERIOR HOLES IN LAWN NEAR CATCH BASIN ALLOWING RATS TO ENTER BUILDING 5415 W RICE ST COMPLAINT FAILED View
DEBRIS, EXCESSIVE JUNK, DEBRIS, CANS, GARBAGE, BRANCHES, LEAVES, ETC. IN REAR YARD 5415 W RICE ST COMPLAINT FAILED View
REPAIR/REBUILD GARAGE OR SHED GARAGE - SERVICE DOOR ROTTING, PAINT PEELING; GAPS AROUND SERVICE DOOR HEADER; GUTTERS, DOWNSPOUT MISSING; WINDOWS BOARDED. 5415 W RICE ST COMPLAINT FAILED View
SERVICE WALK, PASSAGE, AREAWAY SERVICEWALK - BROKEN CONCRETE; SPALLING NEAR GARAGE. 5415 W RICE ST COMPLAINT FAILED View
WORK NOT ALLOWED 2ND FLOOR/ATTIC - REMOVE ALL PARTITIONS AND FIXTURES (INCLUDING PLUMBING AND ELECTRICAL) INSTALLED IN THE ATTIC WITHOUT A PERMIT. 5415 W RICE ST COMPLAINT FAILED View
PLANS & PERMITS REQ - CONTRCTR 2ND FLOOR/ATTIC - SUBMIT PLANS AND OBTAIN PERMIT FOR ALL WORK RELATED TO AUTHORIZE CONVERSION OF ATTIC INTO DWELLING UNITS OR RESTORE THE BUILDING TO THE ORIGINAL STATE. 5415 W RICE ST COMPLAINT FAILED View
REPAIR INTERIOR WALLS/CEILING 2ND FLOOR/ATTIC - LOOSE, BUCKLING DRYWALL NEAR REAR ENTRY DOORINTERIOR STAIRWELL - WALLS - ROUGH AND UNFINISHED; PATCHWORK THRU-OUT;ENCLOSED REAR PORCH - BROKEN DRYWALL AT 1ST FLOOR 5415 W RICE ST COMPLAINT FAILED View
RATS 2ND FLOOR/ATTIC APARTMENT (REAR) - RATS THRU-OUT 5415 W RICE ST COMPLAINT FAILED View
REPAIR FLOOR 2ND FLOOR/ATTIC APARTMENT (REAR) - FLOOR - SOFT VOIDS THRU-OUT KITCHEN;1ST FLOOR FOYER (FRONT ENTRANCE) - DECKBOARDS BUCKLING 5415 W RICE ST COMPLAINT FAILED View
EXIT THROUGH BEDROOM/BATHROOM 2ND FLOOR/ATTIC - REAR EXIT IS THROUGH BATHROOM 5415 W RICE ST COMPLAINT FAILED View
INSTALL SMOKE DETECTORS 2ND FLOOR/ATTIC APARTMENT (REAR)/INTERIOR STAIRWELL/BASEMENT - SMOKE DETECTORS MISSING 5415 W RICE ST COMPLAINT FAILED View
REPAIR INTERIOR STAIR SYSTEM INTERIOR STAIRWELL - SPINDLES MISSING AT HANDRAIL 5415 W RICE ST COMPLAINT FAILED View
REPAIR PORCH SYSTEM NORTH - FRONT PORCH - FOUNDATION STATUS UNKNOWN; SPINDLES MISSING;SOUTH - ENCLOSED REAR PORCH - STRINGERS INADEQUATELY SUPPORTED AT COLUMNS; SUPPORT MISSING UNDERNEATH WINDERS; RAIL HEIGHT ONLY 31"; HANDRAIL NOT CONTINUOUS FROM GRADE TO 2ND FLOOR; HANDRAIL MISSING FROM GRADE TO BASEMENT; HOLES IN ENCLOSURE AND INTERIOR WALLS, DAYLIGHT VISIBLE; DRYWALL MISSING AT 2ND FLOOR (INSULATION EXPOSED), BROKEN WOOD SIDING AT 1ST FLOOR. PLANS AND PERMIT REQUIRED TO REPAIR ENCLOSED REAR PORCH. 5415 W RICE ST COMPLAINT FAILED View
CHIMNEY CAPPING CHIMNEY - CAP MISSING 5415 W RICE ST COMPLAINT FAILED View
HEATING PLANT ENCLOSURE BASEMENT - DRYWALL MISSING IN SOME AREAS; LOOSE, ROTTING MINERAL BOARD USED IN LIEU OF DRYWALL 5415 W RICE ST COMPLAINT FAILED View
CARB MONOX DETECT IN RESID BASEMENT - CARBON MONOXIDE DETECTOR - NOT WORKING AT TIME OF INSPECTION - BEEPING 5415 W RICE ST COMPLAINT FAILED View
CEMENT BASEMENT FLOOR BASEMENT - CONCRETE FLOOR - BROKEN THRU-OUT; TRIP, FALL HAZARD 5415 W RICE ST COMPLAINT FAILED View
STOP/REMOVE NUISANCE ENCLOSED REAR PORCH - TELEVISION ON 1ST FLOOR DECK; OBSTRUCTION 5415 W RICE ST COMPLAINT FAILED View
OBSTRUCTIONS IN EXIT WAY ENCLOSED REAR PORCH - TELEVISION ON 1ST FLOOR DECK; OBSTRUCTION 5415 W RICE ST COMPLAINT FAILED View
SUPPORT FIXTURES ENCLOSED REAR PORCH/2ND FLOOR - CEILING FIXTURE - LOOSE AND HANGING; COVER MISSING 5415 W RICE ST COMPLAINT FAILED View
DEFECTIVE DISTRIBUTION PROVIDE PANEL DIRECTORY. (18-27-384.13) PROVIDE BREAKER FILLERS AT PANELS. (18-27-110.12) REMOVE ILLEGAL SPLICING IN PANEL. (18-27-110.14, 18-27-373.8) 5415 W RICE ST COMPLAINT FAILED View
PROPER SIZE OCP ELECTRIC WATER HEATER IN BASEMENT INADEQUATE SIZED CONDUCTORS AND OVERCURRENT PROTECTION. (18-27-422.13) 5415 W RICE ST COMPLAINT FAILED View
SEE INSPECTOR COMMENTS PROVIDE GFCI PROTECTION FOR RECEPTACLES LOCATED ON EXTERIOR, GARAGE, UNFINISHED BASEMENT, BATHROOMS AND KITCHEN COUNTERTOPS. (18-27-570.8) 5415 W RICE ST COMPLAINT FAILED View
DEFECTIVE GARAGE WIRING WIRING TO GARAGE CONSISTS OF 3 SEPARATE #12 WIRES RUN EXPOSED IN FREE AIR FROM STRUCTURE OF HOUSE ON EXTERIOR TO EXTERIOR OF GARAGE. (18-27-300.4) DANGEROUS AND HAZARDOUS. 5415 W RICE ST COMPLAINT FAILED View
DEFECTIVE DISTRIBUTION 2 CIRCUIT ELECTRICAL PANEL IN GARAGE LACKS GROUND, ENTIRE GARAGE WIRING HAS NO REFERENCE TO GROUND CIRCUIT BREAKERS WILL NOT TRIP. (18-27-110.10) DANGEROUS AND HAZARDOUS. 5415 W RICE ST COMPLAINT FAILED View
DEFECTIVE FIXTURES COVERS AND GLOBES MISSING THROUGHOUT 2ND FLOOR, ALL LIGHTS AND CEILING FANS. BASEMENT HAS BROKEN LIGHT FIXTURES. 5415 W RICE ST COMPLAINT FAILED View
EXPOSED WIRING FIXTURES EXTERIOR FRONT DOOR, BASEMENT, REAR INTERIOR PORCH AND AT CEILING FAN FRONT BEDROOM 2ND FLOOR - DANGEROUS AND HAZARDOUS. 5415 W RICE ST COMPLAINT FAILED View
INSTALL COVERS BASEMENT CEILING AND GARAGE - DANGEROUS AND HAZARDOUS. 5415 W RICE ST COMPLAINT FAILED View
DEFECTIVE OUTLETS 2ND FLOOR KITCHEN ELECTRICAL BOX AND RECEPTACLE ARE NOT SECURED, FALLING OUT OF WALL UNDER KITCHEN SINK. 5415 W RICE ST COMPLAINT FAILED View
HEAT UNIT ADEQUATELY 1ST FLOOR 63 DEGREES IN LIVING ROOM, BEDROOM 59, KITCHEN 61 F AT 2:33PM. 2ND FLOOR BEDROOM #1 61 DEGREES, BEDROOM #2 61 DEGREES, BEDROOM #2 61 DEGREES, KITCHEN 61 DEGREES AT 2:14 PM. HEATING IS OFF AT TIME OF INSPECTION, NO HEAT PROVIDED, GAS SERVICE IS SHUT OFF. 5415 W RICE ST COMPLAINT FAILED View
PROVIDE COLD + HOT WATER WATER SERVICE IN NAME OF MARY GIPSON, ELIGIBLE FOR TERMINATION FOR DEBT OF $6,667.78. LAST PAYMENT MR GIPSON MADE WAS IN FEBRUARY 2014 FOR $40.00 5415 W RICE ST COMPLAINT FAILED View
SUPPLY HOT WTR MIN TEMP 120DEG 1ST AND SECOND FLOORS HOT WATER SUPPLIED AT ONLY 60 DEGREES F. GAS SERVICE SHUT OFF. IF GAS DOES NOT PROVIDE SOURCE OF HOT WATER, PROVIDE HOT WATER AT REQUIRED LEVELS. 5415 W RICE ST COMPLAINT FAILED View
CIRCUIT ONE UNIT ONLY PROVIDE SEPARATE PANEL AND METERING TO SERVE BUILDING COMMON AREA LOADS. (18-27-210.25) CURRENTLY 2 METER SERVICE FEEDS 2 DWELLING UNITS. 5415 W RICE ST COMPLAINT FAILED View
PROPER SIZE GRD ELECTRODE COND THERE IS NO CONNECTION TO WATER PIPE, GROUND STRAP AND FITTING ARE HANGING IN FREE AIR, CONTRARY TO (18-27-250.50) DANGEROUS AND HAZARDOUS. 5415 W RICE ST COMPLAINT FAILED View
DEFECTIVE FEEDER SERVICE CONDUCTORS TERMINATED IN ELECTRICAL PANEL ARE CORRODED CONTRARY TO (18-27-110.3) FOR SUITABILITY AND ARCING POTENTIAL. 5415 W RICE ST COMPLAINT FAILED View
MULTIPLE CONDUCTOR TERM 2 CONDUCTORS TERMINATED ON CIRCUIT BREAKERS DESIGNED FOR TERMINATION OF SINGLE CONDUCTOR. (DANGEROUS AND HAZARDOUS) MULTIPLE TIMES IN ELECTRIC PANELS. 5415 W RICE ST COMPLAINT FAILED View
BOX FOR BX SPLICE GARAGE AND BASEMENT. (DANGEROUS AND HAZARDOUS) NO GROUND CONTINUITY OR REFERENCE TO GROUND. 5415 W RICE ST COMPLAINT FAILED View
CONTINUITY OF RACEWAYS GARAGE - BROKEN CONDUIT. 5415 W RICE ST COMPLAINT FAILED View
SECURE RACEWAY BASEMENT CEILING. 5415 W RICE ST COMPLAINT FAILED View
SECURE SEC STRAP MISSING ON DETERIORATED SE CABLE ON EXTERIOR . 5415 W RICE ST COMPLAINT FAILED View
CLEAN CATCH BASIN (18-29-1003.4) (7-28-580) 5415 W RICE ST COMPLAINT FAILED View
REPAIR/REBUILD GARAGE OR SHED SOUTH ELEVATION - GARAGE - FACIA BOARD HANGING OFF SOFFIT ON ALLEY SIDE. 5415 W RICE ST COMPLAINT FAILED View
REPAIR EAVES EAST AND NORTH ELEVATION - WOOD SOFFIT AND FACIA - ROTTED WITH LARGE HOLES. 5415 W RICE ST COMPLAINT FAILED View
REPAIR GUTTER & DOWNSPOUT EAST ELEVATION - GUTTER AND DOWNSPOUT - MISSING. 5415 W RICE ST COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# BUILDING- NO OWNER'S ID SIGN POSTED. 5415 W RICE ST COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION INTERIOR OF BUILDING - NO RESPONSE, UNABLE TO VERIFY DETECTORS, INTERIOR CONDITIONS AND COMPLAINT OF BUILDING INTERIOR ALTERATIONS. 5415 W RICE ST COMPLAINT FAILED View
REPAIR EXTERIOR STAIR FRONT RAMP - FOUNDATION STATUS UNKNOWN; RAMP COLLAPSING AT WALKWAY; STRINGER INADEQUATELY SUPPORTED AT COLUMNS, LEANING; DECKBOARDS CUPPING; LOOSE, PROTRUDING TOPRAIL, CUPPING AND UNATTACHED; SPINDLES MISSING AT GUARDRAILS; OPEN RISERS FROM GRADE TO 1ST FLOOR. PLANS AND PERMIT REQUIRED TO REPAIR FRONT RAMP. 5415 W RICE ST COMPLAINT FAILED View
CUT OR REMOVE HIGH WEEDS EAST, SOUTH ELEVATIONS - WEEDS THRU-OUT 5415 W RICE ST COMPLAINT FAILED View
DWELLING CLEAN AND SANITARY ENCLOSED REAR PORCH - DIRT THRU-OUT; UNSANITARY 5415 W RICE ST COMPLAINT FAILED View
REPAIR DOOR, INT. 2ND FLOOR/ATTIC - INTERIOR DOORS - LOOSE FRAMES 5415 W RICE ST COMPLAINT FAILED View
COVER OUTLETS AND JBS RECEPTACLE AND SWITCH COVERS MISSING/BROKEN 2ND FLOOR BEDROOMS AND KITCHEN. 5415 W RICE ST COMPLAINT FAILED View
ARMORED CABLE BASEMENT EXPOSED RUNS AND USED AS PRIMARY WIRING METHOD OF BASEMENT BATHROOM. 5415 W RICE ST COMPLAINT FAILED View
ACCESS TO JBS IN BASEMENT BURIED JUNCTION BOX BEHIND FRAMING FOR WINDOW. 5415 W RICE ST COMPLAINT FAILED View
REPAIR DEFECTIVE DOWNSPOUT EAST GUTTER AND CONNECT DOWNSPOUT TO SEWER SYSTEM.(18-29-1101.2.1) (7-28-060) 5415 W RICE ST COMPLAINT FAILED View
PROVIDE PROVIDE A FLOOR DRAIN IN WATER HEATER AREA.(18-29-501.3) 5415 W RICE ST COMPLAINT FAILED View
REMV OBSTR FROM DRAINAGE SYSTM FIRST FLOOR LAVATORY. (13-168-120) (18-29-301.3) (11-16-020)(11-16-020) (18-29-102.3) 5415 W RICE ST COMPLAINT FAILED View
PROPER MATERIAL FOR HSE DRAIN REMOVE ALL PVC PIPING BELOW GRADE.(13-168-480) (13-168-490) (18-29-702.2) 5415 W RICE ST COMPLAINT FAILED View
PROPER MATRL WATER SUPPLY PIPE REMOVE ALL FLEX AND PVC WATER SUPPLIES FROM SINKS, WATERCLOSETS THROUGHOUT. REMOVE METAL CLAMP ON WATER SERVICE FRONT LOCATION. REMOVE PVC PIPE ON WATER HEATER - DISCHARGE. (11-8-570) (18-29-605.4 THRU 9) 5415 W RICE ST COMPLAINT FAILED View
VENT SYSTEM TO PRVNT BACK PRES SECOND FLOOR KITCHEN SINK. (13-168-790) (18-29-901.2) 5415 W RICE ST COMPLAINT FAILED View
STOP LEAKING WATER FIRST FLOOR CEILING IN DINING ROOM. SECOND FLOOR BATHTUB - SEAL WALLS. FIRST FLOOR KITCHEN SINK.(13-168-1480) (18-29-705.1 THRU 16) (13-168-120) 5415 W RICE ST COMPLAINT FAILED View
CLEAN CATCH BASIN (7-28-580) (18-29-1003.4) 5415 W RICE ST COMPLAINT FAILED View
REPAIR CATCH BASIN (18-29-102.3) (18-29-1003.4) SINKING ON ONE SIDE.(13-168-1280) 5415 W RICE ST COMPLAINT FAILED View
PRV WATER PIPES PROPER SIZE 3/4 INCH PIPE REQUIRED FOR WATER HEATER INLET.(18-29-604.10) (18-29-502.1) (11-8-540) 5415 W RICE ST COMPLAINT FAILED View
REPLACE DEFECTIVE FAUCET (18-29-102.3) (13-168-120) (18-29-420.1) SECOND FLOOR BATHTUB HANDLE, SLEEVE AND FLANGE MISSING. 5415 W RICE ST COMPLAINT FAILED View
REPL DEFECTIVE BATHROOM FLOOR FIRST AND SECOND FLOOR TILE MISSING.(13-196-540-F) (18-29-405.2.1) 5415 W RICE ST COMPLAINT FAILED View
REPLACE DEFECTIVE PLBG FIXTURE FIRST FLOOR KITCHEN SINK - WOOD ROTTON. SECOND FLOOR TILE MISSING. (18-29-405.2.1) (13-196-540F)THE SECOND FLOOR SINK HAS NO BASE - BATHTUBS ON BOTH FLOORS MUST BE REFINISHED - DUE TO WORN PORCELAIN AND RUST. 5415 W RICE ST COMPLAINT FAILED View
OBTN PERMIT FOR PLUMBING WORK (18-29-106.1) (13-168-060) 5415 W RICE ST COMPLAINT FAILED View
LICENSED BONDED PLMBG CONTRCTR (18-29-106.2) 1(4-332-010-100) (13-168-070) 5415 W RICE ST COMPLAINT FAILED View
REMOVE STAGNANT WATER BSMT REPAIR BROKEN SEWER NEAR EAST WALL.(13-196-580A) (7-28-060) (11-16-020) 5415 W RICE ST COMPLAINT FAILED View