Last Modification Date: 2024-10-26 @ 12:56 AM
PIN: 13254110150000
Property Address: 2618 N ROCKWELL ST
City - Zip: CHICAGO - 60647
2023 Property Class: 315
2023 Township: 77 - West Chicago
2023 Neighborhood: 77150
2023 Tax District: 77135
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 13 Violations
Violation Inspector Comments Address Category Status View
FLAKY INTERIOR PAINT NORTHWEST OPEN PORCH FLAKY PAINT. SOUTH PORCH & SOUTH PORCH. 2618 N ROCKWELL ST PERIODIC FAILED View
REPAIR PORCH SYSTEM SOUTHWESR OPEN PORCH MISSING HATCH DOOR COVER SOUTHEAST WOOD PORCH RISERS VARIOUS LOCATIONS 2-3 EXPOSED NAIL ON TREADS / RISERS. 2X4 UPRIGHT WINDER EXCESSIVE SCABBED AND OUT OF PLUMB.SOUTHWEST CORNER PORCH 2 & 3 FLOORS FLOOR BOARDS WEAK & MISSING NAILS WORBLING. 2618 N ROCKWELL ST PERIODIC FAILED View
PERMIT REQUIRED - CONTRACTOR OBTAIN PERMIT TO REPAIR / REPLACE SOUTHEAST PORCH & SOUTHWEST PORCH 2618 N ROCKWELL ST PERIODIC FAILED View
POST OWNER/MANAGERS NAME/# MANAGEMENT SIGN MISSING ADDRESS 2618 N ROCKWELL ST PERIODIC FAILED View
ARRANGE PREMISE INSPECTION TERNANT @ 2618 BASEMENT REFUSED ENTRY TO ANSWER COMPLAINT OR VERIFY SMOKE DETECTOR OR OCCUPANCY. 2618 N ROCKWELL ST PERIODIC FAILED View
REPAIR PORCH SYSTEM PORCH 1 (SOUTH): 6X6 COLUMNS SHOWN AT PLANS 4X6 COLUMNS PROVIDED. STRINGER TO MASONRY WALL NOT MOUNTED AS PER PLANS. DOUBLE 2X10 STRINGERS REQUIRED AT PLANS. SINGLE CUT STRINGERS PROVIDED. MISSING LEDGER BOLTS AT ALL LEVELS; PORCH 2 (SOUTHWEST): ALL LEVELS DOUBLE 2X10 BEAMS BOLTED ALONG SIDE OF COLUNS AND NOT SUPPORTED AT COLUMNS BY METAL ANGLE BRACKETS. PLANS REQUIRE BEAMS TO BE BUTTED TO COLUMNS AND SUPPORTED BY ANGLE BRACKETS. 1" DIAMETER BOLTS REQUIRED AT ANGLE BRACKETS, 3/4" DIAMETER BOLTS IN PLACE. MISSING LEDGER BOLTS AT ALL LEVELS; PORCH 3 (NORTHWEST): ALL LEVELS DOUBLE 2X10 BEAMS ALONG SIDE OF COLUMNS AND NOT SUPPORTED AT COLUMNS BY METAL ANGLE BRACKETS. PLANS REQUIRE BEAMS TO BE BUTTED TO COLUMNS AND SUPPORTED BY ANGLE BRACKETS. AT BEAM SPLICES METAL STRAPS MISSING. BEAM SPLICE NOT SUPPORTED. 1" DIAMETER BOLTS REQUIRED AT ANGLE BRACKETS, 3/4" DIAMETER BOLTS IN PLACE. STAIR STRINGERS ARE SINGLE 2X10'S DOUBLE 2X10'S REQUIRED BY PLAN. MISSING LEDGER BOLTS AT ALL LEVELS; PORCH 4 (NORTH): 6X6 COLUMNS SHOWN AT PLANS, 4X6 COLUMNS PROVIDED. DOUBLE 2X10 POCKETED BEAMS REQUIRED AT PLANS. BEAMS END AT COLUMN, ONE SIDE OF BEMA POCKETED, NO BRACKETS AT POCKETED END. DOUBLE 2X10 STRINGERS REQUIRED AT PLANS. SINGLE CUT STRINGERS PROVIDED. MISSING LEDGER BOLTS AT ALL LEVELS; PLANS DO NOT ADDRESS SPECIFIC CONSTRUCTION OF WINDING STAIRS AT DETAIL PAGE AND CONFLICT WETIH THEMSELVES AT PORCH 4 (NORTH) REGARDING POCKETED BEAMS. PLANS ALSO SHOW BEAMS BETWEEN COLUMNS AT PORCH 2 (SOUTHWEST). MANY DEVIATIONS FROM PLANS BY CONTRACTOR. REVISIONS REQUIRED BY PREVIOUS INSPECTOR REGARDING DECK JOIST ORIENTATION AT PORCH 3 (NORTHWEST). USE OF 4X6 COLUMNS AND COLUMN SPLICE BOLT CONFIGURATION AT PORCH 1 (SOUTH) AND PORCH 4 (NORTH) HAND DRAWN OVER ORIGINA PLANS. DCAP APPROVED REVISIONS NEEDED. 2618 N ROCKWELL ST PERMIT PASSED View
REPAIR EXTERIOR WALL AT COURTYARD NORTH AND SOUTH ELEVATIONS OPEN MORTAR JOINTS AND DETERIORATING BRICKWORK OVER 3RD FLOOR WINDOWS. 2618 N ROCKWELL ST PERIODIC FAILED View
REPAIR EXTERIOR WALL ALL FACE BRICK ELEVATIONS; FRACTURES OFF OF LINTELS, VERTICAL FRACTURES AT RAISED BRICK FLANKING WINDOWS. SPALLING BRICK VARIOUS LOCATIONS EAST ELEVATION. ERODING MORTAR EAST ELEVATION AND COURT YARD. OPEN MORTAR JOINTS VARIOUS LOCATIONS COURT YARD AND EAST ELEVATION. SOUTH ELEVATION BESIDE PORCH; SPALLING BRICK, ERODING MORTAR. NORTH ELEVATION BELOW WINDOWS; SPALLING BRICK, OPEN MORTAR JOINTS. WEST ELEVATION BELOW WINDOWS AT 3 SPALLING BRICK, ERODING MORTAR. NORTH ELEVATION FLAKING PAINT, ERODING MORTAR, SPALLING BRICK, EFFLORESCENCE, FRACTURES, OPEN MORTAR JOINTS. 2618 N ROCKWELL ST PERIODIC FAILED View
REPAIR LINTELS EAST ELEVATION AND COURT YARD; RUSTING LINTELS, SOME LINTELS SAGGING. NORTH ELEVATION SAGGING, RUSTING LINTELS. 2618 N ROCKWELL ST PERIODIC FAILED View
CHIMNEY WEST ELEVATION CHIMNEY; LOOSE PARGE COAT, SPALLING BRICK, OPEN MORTAR JOINTS, ERODING MORTAR. 2618 N ROCKWELL ST PERIODIC FAILED View
REPAIR WINDOW SILLS OPEN SILL JOINTS NORTH ELEVATION. OPEN SILL JOINTS COURT YARD AND EAST ELEVATION. OPEN SILL JOINTS VARIOUS LOCATIONS THROUGHOUT. 2618 N ROCKWELL ST PERIODIC FAILED View
PARAPET PARAPET WALL IN COURT YARD, EAST ELEVATION, ALL FACE BRICK ELEVATIONS; FRACTURES, ERODING MORTAR, SOME SPALLING BRICK. 2618 N ROCKWELL ST PERIODIC FAILED View
ARRANGE PREMISE INSPECTION NO ENTRY INTERIOR, NO RESPONSE. UNABLE TO VERIFY DETECTORS AND OCCUPANCY. 2618 N ROCKWELL ST PERIODIC FAILED View