Chicago Building Violations Data: 74 Violations
Violation Inspector Comments Address Category Status View
HEAT UNIT ADEQUATELY 44-N 3RD FLOOR APARTMENT TEMPERATURE 63 DEGREE 42 N WALLER AVE COMPLAINT FAILED View
CARB MONOX DETECT IN RESID 44 N 3RD FLOOR APARTMENT NO CARBON MONOXIDE DETECTORS. 42 N WALLER AVE COMPLAINT FAILED View
HEAT HABITABLE ROOM 44- N. 3RD FLOOR APARTMENT 2 RADIATORS NOT ON COLD AT TIME OF INSPECTION. 42 N WALLER AVE COMPLAINT FAILED View
HEAT UNIT ADEQUATELY #2, #3 63, 61 DEGREES 42 N WALLER AVE COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# OWNERS ID SIGN NO POSTED 42 N WALLER AVE PERIODIC FAILED View
FILE BLDG REGISTRATION BUILDING NOT REG. FROM 2006 TO 2007 42 N WALLER AVE PERIODIC FAILED View
MICE/RODENTS 46N/APT 702 703 46N/APT501 MICE 42 N WALLER AVE PERIODIC FAILED View
REPLACE DEFECTIVE TOILET SEAT 46N/APT501 TOILET SEAT LOOSE. 42 N WALLER AVE PERIODIC FAILED View
REPAIR EXTERIOR DOOR FRAME 52N/APT 153 REAR DOOR BROKEN JAM AND FRAME 42 N WALLER AVE PERIODIC FAILED View
REPAIR SKYLIGHT 46N SKYLIGHT CRACKED WITH LEAKING WATER 42 N WALLER AVE PERIODIC FAILED View
ROACHES 46N/APT 501 52N/APT143 ROACHES 42 N WALLER AVE PERIODIC FAILED View
INT WALL/CEILING CHIP PLASTER 46N/INT. STAIRWAY AT 3RD FLR. WALLS FALLING PLASTERS 42 N WALLER AVE PERIODIC FAILED View
REPAIR/REPLACE SMOKE DETECTORS STAIRWELL SMOKE DETECTOR NEEDS BATTERY AT 52. 42 N WALLER AVE PERIODIC FAILED View
REPAIR EXTERIOR DOOR HARDWARE FRONT ENTRY DOOR LOCK BROKEN AT 52 42 N WALLER AVE PERIODIC FAILED View
DEFECTIVE FIXTURES SYSTEM III FIXTURE BROKEN AT GRADE 52 42 N WALLER AVE PERIODIC FAILED View
INSTALL DOOR VIEWING DEVICE SOME UNITS ALL ENTRIES MISSING PEEHOLES 42 N WALLER AVE PERIODIC FAILED View
REPAIR AREAWAY WALL SOUTH SERVICE PASSAGE EXPOSED LATH 42 N WALLER AVE PERIODIC FAILED View
REPAIR/REPLACE SMOKE DETECTORS STAIRWELL SMOKE DETECTOR NEEDS BATTERY AT 52. 42 N WALLER AVE PERIODIC FAILED View
REPAIR EXTERIOR DOOR HARDWARE FRONT ENTRY DOOR LOCK BROKEN AT 52 42 N WALLER AVE PERIODIC FAILED View
DEFECTIVE FIXTURES SYSTEM III FIXTURE BROKEN AT GRADE 52 42 N WALLER AVE PERIODIC FAILED View
INSTALL DOOR VIEWING DEVICE SOME UNITS ALL ENTRIES MISSING PEEHOLES 42 N WALLER AVE PERIODIC FAILED View
REPAIR AREAWAY WALL SOUTH SERVICE PASSAGE EXPOSED LATH 42 N WALLER AVE PERIODIC FAILED View
SUPPLY HOT WTR MIN TEMP 120DEG 42 / APT 202 / HOT WATER SUPPLIED AT ONLY 116F 42 N WALLER AVE COMPLAINT FAILED View
OBSTRUCTIONS IN EXIT WAY SOUTHWEST PORCH - MISCELLANEOUS ITEMS STORED AT 2ND FLOOR 42 N WALLER AVE PERIODIC FAILED View
REPAIR PORCH SYSTEM SOUTHEAST PORCH - 1ST STEP FROM GRADE TOO HIGH 10"; LEDGER BOARDS NOT BOLTED TO WALL; 2X8 JOISTS UNDERSIZED FOR SPAN OF DECKS; COLUMN SPLICES ONLY 12" LONG WITH 2 BOLTS; 6X6 COLUMN BOWED FROM 2ND TO 3RD FLOOR; HANDRAILS MISSING PICKETS; GUARDRAILS LESS THAN 42" HIGH; STAIR STRINGERS NAILED; 2ND TO 3RD FLOOR CENTER STAIR STRINGER PULLED AWAY FROM JOIST; PLANS AND PERMIT REQUIRED FOR REPAIRS TO PORCHSOUTHWEST PORCH - 4X4 COLUMNS NO FOOTINGS; BASE OF COLUMNS SEATED ON CONCRETE SLAB; 4X4 COLUMNS AT GUARDRAILS NOT BOLTED TO WALL; GUARDRAILS LESS THAN 42" HIGH; LEDGER BOARDS NOT BOLTED TO WALL;PERMIT REQUIRED FOR REPAIRS TO PORCH; WEST AND NORTH PORCHES NOT INSPECTED, NO ACCESS. 42 N WALLER AVE PERIODIC FAILED View
REPLCE WINDOW PANES, PLEXGLAS 46 COURTYARD - 2ND FLOOR BROKEN PANE 42 N WALLER AVE PERIODIC FAILED View
ARRANGE PREMISE INSPECTION NO ENTRY TO INTERIOR AND SEVERAL REAR PORCHES AT TIME OF INSPECTION 42 N WALLER AVE PERIODIC FAILED View
REPAIR AREAWAY WALL SOUTH SERVICE PASSAGE EXPOSED LATH 42 N WALLER AVE PERIODIC FAILED View
REPAIR PORCH SYSTEM 6 REAR PORCHES -NORTHEAST AND SOUTHEAST PORCHES1. 6X6 AND 4X4 COLUMNS RESTING ON CONCRETE SLAB.2. FOUNDATION STATUS UNKNOWN.3. 6X6 AND 4X4 COLUMNS OVER NOTCHED.4. 2X8 JOIST OVER SPANNED.5. STRINGERS INADEQUATELY SUPPORTED.6. STAIR TREADS UNDERSIZED WITH OPEN RISERS.7. GUARDRAILS UNDER 42 INCHES IN HEIGHT.8. LEDGER BEAM INADEQUATELY SUPPORTED AT BUILDING.9. 2X8 JOISTS INADEQUATELY SUPPORTED AT BEAM.10. PLANS AND PERMIT REQUIRED.NORTH AND SOUTHWEST PORCHES -1. 4X4 COLUMNS RESTING ON SLAB.2. FOUNDATION STATUS UNKNOWN.3. 4X4 COLUMNS USED FOR SUPPORT OVER 12 FEET IN HEIGHT.4. 4X4 COLUMNS OVER NOTCHED.5. STRINGERS INADEQUATELY SUPPORTED.6. STAIR TREADS UNDERSIZED.7. 2X8 JOIST INADEQUATELY SUPPORTED AT BEAM.8. PLANS AND PERMIT REQUIRED.NORTH AND SOUTH CENTER PORCHES -1. 4X4 COLUMNS RESTING ON CONCRETE SLAB.2. FOUNDATION STATUS UNKNOWN.3. 4X4 COLUMNS OVER NOTCHED.4. LEDGER BEAM INADEQUATELY SUPPORTED TO BUILDING.5. 2X8 JOIST INADEQUATELY SUPPORTED AT BEAM.6. STRINGERS INADEQUATELY SUPPORTED.7. GUARDRAILS UNDER 42 INCHES IN HEIGHT.8. PLANS AND PERMIT REQUIRED. 42 N WALLER AVE PERIODIC FAILED View
POST OWNER/MANAGERS NAME/# MANAGEMENT SIGN INCOMPLETE - MISSING MAILING ADDRESS. 42 N WALLER AVE PERIODIC FAILED View
NO POSTED ADDRESS POST COMPLETE ADDRESS RANGE OF BUILDING SO IT IS VISIBLE FROM THE STREET. 42 N WALLER AVE PERIODIC FAILED View
CHIMNEY FRACTURES AND WASHED OUT MORTAR. 42 N WALLER AVE PERIODIC FAILED View
REPAIR EXTERIOR WALL NORTH ELEVATION UNDER 3RD FLOOR WINDOWS - SPALLING BRICKS AND WASHED OUT MORTAR. 42 N WALLER AVE PERIODIC FAILED View
PARAPET NORTH AND WEST ELEVATION PARAPET WALLS - SPALLING BRICKS AND WASHED OUT MORTAR. 42 N WALLER AVE PERIODIC FAILED View
REPAIR WINDOW SILLS WINDOW SILLS - WASHED OUT MORTAR. 42 N WALLER AVE PERIODIC FAILED View
SCREEN OUTER DOORS, WINDOWS ALL ELEVATIONS VARIOUS LOCATIONS - MISSING WINDOW SCREENS. 42 N WALLER AVE PERIODIC FAILED View
PERMIT REQUIRED - CONTRACTOR NO PERMIT ON FILE FOR INSTALLATION OF 8 FOOT HIGH WROUGHT IRON FENCE. 42 N WALLER AVE PERIODIC FAILED View
REPAIR INTERIOR WALLS/CEILING CEILING AT SKYLIGHT - WATER DAMAGE, EXPOSED WOOD. 42 N WALLER AVE PERIODIC FAILED View
INSTALL SMOKE DETECTORS MISSING SMOKE DETECTOR. 42 N WALLER AVE PERIODIC FAILED View
MICE/RODENTS MICE PRESENT. 42 N WALLER AVE PERIODIC FAILED View
FILE BLDG REGISTRATION NOT REGISTERED FOR 2011. 42 N WALLER AVE PERIODIC FAILED View
CHIMNEY FRACTURES AND WASHED OUT MORTAR. 42 N WALLER AVE PERIODIC FAILED View
REPAIR EXTERIOR WALL NORTH ELEVATION UNDER 3RD FLOOR WINDOWS - SPALLING BRICKS AND WASHED OUT MORTAR. 42 N WALLER AVE PERIODIC FAILED View
PARAPET NORTH AND WEST ELEVATION PARAPET WALLS - SPALLING BRICKS AND WASHED OUT MORTAR. 42 N WALLER AVE PERIODIC FAILED View
REPAIR WINDOW SILLS WINDOW SILLS - WASHED OUT MORTAR. 42 N WALLER AVE PERIODIC FAILED View
SCREEN OUTER DOORS, WINDOWS ALL ELEVATIONS - VARIOUS LOCATIONS - MISSING WINDOW SCREENS. 42 N WALLER AVE PERIODIC FAILED View
INSTALL SMOKE DETECTORS MISSING SMOKE DETECTOR. 42 N WALLER AVE PERIODIC FAILED View
ROACHES ROACHES. 42 N WALLER AVE PERIODIC FAILED View
FILE BLDG REGISTRATION NOT REGISTERED FOR 2011. 42 N WALLER AVE PERIODIC FAILED View
INSPECT CONSTRUCTION WORK SIX 3-STORY REAR PORCH REPAIRED UNDER PERMIT # 100385213, ISSUED ON 08/18/2011. PLANS AND PERMIT NOT AVALIABLE ON SITE FOR INSPECTOR'S REVIEW AND WORK APPROVAL. 42 N WALLER AVE PERIODIC FAILED View
ARRANGE PREMISE INSPECTION INTERIOR OF BLDG: NO RESPONSE - UNVERIFIED DETECTORS AND CONDITIONS. UNABLE TO VERIFY COMPLAINTS OF BED BUGS AT 52 N. / APT. 142 42 N WALLER AVE PERIODIC FAILED View
REPLCE WINDOW PANES, PLEXGLAS 1ST FLOOR 48&50 - BROKEN WINDOWS 42 N WALLER AVE PERIODIC FAILED View
REPAIR EXTERIOR DOOR SILL ENTRANCE DOOR 46 - BROKEN AND SPALLED LIMESTONE SILL 42 N WALLER AVE PERIODIC FAILED View
MICE/RODENTS INTERIOR OF BUILDING - MICE, PROFESSIONAL EXTERMINATOR TO ABATE MICE. BUILDING DEPARTMENT WILL NOT CONSIDER THIS VIOLATION COMPLIED WITHOUT PROOF OF SAID EXTERMINATION 42 N WALLER AVE PERIODIC FAILED View
REPAIR EXTERIOR DOOR HARDWARE ENTRANCE DOORS 46 & 50 - BROKEN DOOR LATCHES AND CLOSERS 42 N WALLER AVE PERIODIC FAILED View
MICE/RODENTS MICE PRESENT. 42 N WALLER AVE PERIODIC FAILED View
ROACHES ROACHES. 42 N WALLER AVE PERIODIC FAILED View
ARRANGE PREMISE INSPECTION UNABLE TO GAIN ENTRY TO VERIFY OCCUPANCY,DETECTORS,PORCHES AND OVERALL CONDITIONS.UNABLE TO GAIN ENTRY TO 44 N WALLER 2ND FLOOR TO VERIFY COMPLAINT OF LEAK IN BATHROOM CEILING AND RADIATORS.SMOKE DETECTOR ISN'T WORKING. 42 N WALLER AVE PERIODIC FAILED View
REPAIR FLOOR GRADE ENTRANCE DOOR 46 - MISSING AND BROKEN FLOOR TILES 42 N WALLER AVE PERIODIC FAILED View
REPAIR INTERIOR STAIR SYSTEM 52 STAIRWAY , GRADE TO 1ST FLOOR - MISSING BALUSTERS. 42 N WALLER AVE PERIODIC FAILED View
REPLCE WINDOW PANES, PLEXGLAS 1ST FLOOR 42,48 & 50 - BROKEN WINDOWS AT VARIOUS LOCATIONS. 42 N WALLER AVE PERIODIC FAILED View
REPAIR DOOR, INT. 52 ENTRANCE VESTIBULE DOOR - MISSING CASING BOARDS, MISSING GLASS PANELS. 42 N WALLER AVE PERIODIC FAILED View
SEE INSPECTOR COMMENTS BOILER OUT OF SERVICE AT TIME OF INSPECTION, MAKE REPAIRS TO BOILER #1 PEERLESS CIS TO PROVIDE HEAT IN BUILDING. 42 N WALLER AVE PERIODIC CLOSED View
OWNER OR LICENSED CONTRACTOR 42 N WALLER AVE PERIODIC CLOSED View
ARRANGE FOR REINSPECTION REGAR INTERIOR OF BUILDING , NO RESPONSE . UNABLE TO VERIFY SMOKE OR CARBON MONOXIDE ALARMS. 42 N WALLER AVE PERIODIC FAILED View
STOP/REMOVE NUISANCE DOOR 46 / APT 502 - BATHROOM AND KITCHEN SINKS ARE CLOGGED 42 N WALLER AVE PERIODIC FAILED View
PARAPET & COPING ALL ELEVATIONS - FRACTURES,LOOSE MORTAR WITH OPEN JOINTS ON COPINGS AT VARIOUS LOCATIONS 42 N WALLER AVE PERIODIC FAILED View
SCREEN OUTER DOORS, WINDOWS ALL ELEVATIONS - MISSING OR TORN SCREENS 42 N WALLER AVE PERIODIC FAILED View
REPAIR EXTERIOR DOOR SILL ENTRANCE DOORS 44,48 & 50 - BROKEN AND SPALLED LIMESTONE SILLS 42 N WALLER AVE PERIODIC FAILED View
REPAIR EXTERIOR DOOR HARDWARE ENTRANCE DOORS 42, 46, 48 ,50 & 52 - BROKEN DOOR LATCHES AND CLOSERS 42 N WALLER AVE PERIODIC FAILED View
REPAIR WINDOW SILLS ALL ELEVATIONS - OPEN SILL JOINTS AT VARIOUS LOCATIONS. 42 N WALLER AVE PERIODIC FAILED View
STOP/REMOVE NUISANCE NORTH SERVICE WALK - DOG FECES THRU-OUT , RAT HARBORAGE. 42 N WALLER AVE PERIODIC FAILED View
ARRANGE FOR REINSPECTION REGAR INTERIOR OF BUILDING , NO ENTRY NO RESPONSE . UNABLE TO VERIFY SMOKE OR CARBON MONOXIDE ALARMS. ENTRY INTO STAIRWAYS ONLY. 42 N WALLER AVE PERIODIC FAILED View
REPAIR/REPLACE SMOKE DETECTORS STAIRWAYS 46 AND 52 - LOW BATTERY,BEEPING SMOKE ALARMS, REPLACE WITH 10YR BATTERY SMOKE ALARMS. PER SEC.(14X-5-504.8.4) 42 N WALLER AVE PERIODIC FAILED View