The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
PARAPET | SR06-01208298 - PARAPET WALLS AT SOUTH BULGING, OPEN MORTAR AND FRACTURE. PERMIT IS REQUIRED FOR MASONRY REPAIRS. | 5103 W HURON ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | EXTERIOR WALLS OPEN MORTAR AND FRACTURE. | 5103 W HURON ST | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | NO OWNER ID POSTED. | 5103 W HURON ST | COMPLAINT | FAILED | View |
ARRANGE FOR REINSPECTION REGAR | NO ENTRY TO INTERIOR TO VERIFY DETECTOR OR EXTERIOR TO INSPECT PORCH SYSTEM LOCK GATE AT REAR. | 5103 W HURON ST | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | REAR GATE CHAIN AND PADLOCK. | 5103 W HURON ST | COMPLAINT | FAILED | View |
REPAIR / REBUILD SHED | REAR GARAGE LOOSE AND MISSING BRICKS AT REAR WALL. | 5103 W HURON ST | COMPLAINT | FAILED | View |
NO KEY TO USE EXIT DOOR | REAR YARD FENCE CHAIN AND PADLOCK. | 5103 W HURON ST | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | DEBRIS REAR YARD. | 5103 W HURON ST | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | REAR PORCH 5109 INADEQUATE SUPPORT OF COLUMN AND LOOSE BEAM UNSECURE AT 2ND FLOOR COLUMN REAR 5103 LEDGER BEAM MISSING BOLTS 2ND FLOOR, LOOSE STRINGERS 1ST TO 2ND FLOOR PLANS AND PERMIT REQUIRED FOR PORCH REPAIRS | 5103 W HURON ST | COMPLAINT | FAILED | View |
PARAPET | WEST ELEVATION PARAPET WALL LOOSE AND WASHED OUT MORTER JOINTS SPALLING BRICKS. | 5103 W HURON ST | COMPLAINT | FAILED | View |
REPAIR LINTELS | EAST AND NORTH ELEVATION 1ST AND 2ND FLRS VARIOUS LOCATIONS LINTELS RUSTING AND DEFLECTING. | 5103 W HURON ST | COMPLAINT | FAILED | View |
REPAIR/REBUILD GARAGE OR SHED | NORTH ELEVATION OF GARAGE BRICKS FALLING AND WALL IS BOWING OUT. | 5103 W HURON ST | COMPLAINT | FAILED | View |
FILE BLDG REGISTRATION | BUILDING NOT REGISTERED FROM 1990 NTHRU 2010. BL00942 | 5103 W HURON ST | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | EAST YARD - GARBAGE, NEWS PAPERS, CARDBOARD BOXES AND OPEN TRASH BINS. | 5103 W HURON ST | COMPLAINT | FAILED | View |
PARAPET | SOUTH ELEVATION/ PARAPET WALL - SPALLING BRICKS WITH WASHED OUT MORTAR. | 5103 W HURON ST | COMPLAINT | FAILED | View |
FILE BLDG REGISTRATION | BUILDING - NOT REGISTERED FROM 2012 THRU 2014. | 5103 W HURON ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | 5103-5105 W./ REAR 2 STORY WOOD PORCH / TREADS - LOOSE.( TRIPPING HAZARD). | 5103 W HURON ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | ALL APARTMENTS EXCLUDING 5105 W./ APTS. 1E AND 1W - NO RESPONSE. UNABLE TO VERIFY DETECTORS, CONDITIONS AND OCCUPANCY. UNABLE TO INSPECT INTERIOR STAIRWAYS. | 5103 W HURON ST | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | NO OWNER'S ID SIGN POSTED. | 5103 W HURON ST | COMPLAINT | FAILED | View |
SCREEN OUTER DOORS, WINDOWS | WINDOWS MISSING SCREENS. | 5103 W HURON ST | COMPLAINT | FAILED | View |
INSTALL DEAD BOLT LOCK | ENTRANCE DOOR MISSING DEADBOLT LOCK. | 5103 W HURON ST | COMPLAINT | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | FRONT STAIR TREADS AT GRADE TO 1ST WEAK, 2ND MISSING PICKETS. | 5103 W HURON ST | COMPLAINT | FAILED | View |
CUT OR REMOVE HIGH WEEDS | HIGH WEED OVER 3FT. | 5103 W HURON ST | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | PROVIDE APPROVED PLANS AND PERMITS FOR INTERIOR ALTERATIONS TO EXISTING STRUCTURE, SEE ALL DRYWALL REMOVED, PLUMBING AND ELECTRICAL REMOVED. CURRENTLY WORKING UNDER PERMIT #100600951. STOP WORK ORDER ISSUED FOR EXCEEDING SCOPE ON PERMIT. | 5103 W HURON ST | COMPLAINT | PASSED | View |
REPLACE D&H PORCH | REAR PORCH WITH THE FOLLOWING DEFECTS: 1). BEAM TO COLUMN CONNECTIONS NAILED ONLY. 2). STRINGER CONNECTIONS NAILED ONLY. 3). TREADS CUPPED AND CRACKED THRU-OUT. 4). 6X6 COLUMNS LAP JOINTS UNDERSIZED. 5). GUARDRAILS WEAK AND DEFLECT UNDER LOAD. 6). HANDRAILS WEAK AND DEFLECT. 7). PLANS AND PERMITS REQUIRED FOR REPLACEMENT. | 5103 W HURON ST | COMPLAINT | PASSED | View |
HEAT UNIT ADEQUATELY | NO WORKING HEAT THROUGHOUT BUILDING. | 5103 W HURON ST | COMPLAINT | PASSED | View |
SAFE WORKING CONDITIONS | NON-WORKING FURNACE AT TIME OF INSPECTION. | 5103 W HURON ST | COMPLAINT | PASSED | View |
INSTALL SMOKE DETECTORS | NO WORKING SMOKE DETECTORS THROUGHOUT BUILDING. | 5103 W HURON ST | COMPLAINT | PASSED | View |
CARB MONOX DETECT IN RESID | NO WORKING CARBON MONOXIDE DETECTORS PRESENT AT TIME OF INSPECTION. | 5103 W HURON ST | COMPLAINT | PASSED | View |
DEFECTIVE LIGHTING SERVICE | EXISTING SERVICE INADEQUATE. PROVIDE LOAD CALCULATIONS AND ONE LINE DRAWING FOR SERVICE AND EMERGENCY LIGHTING. (18-27-215.5) | 5103 W HURON ST | COMPLAINT | PASSED | View |
SYSTEM III | NO EMERGENCY LIGHTING PRESENT. | 5103 W HURON ST | COMPLAINT | PASSED | View |
INSTALL ILLUMINATION | PROVIDE ALL GENERAL LIGHTING, EXTERIOR DOORS, STAIRWAYS, BASEMENTS INCLUDED. | 5103 W HURON ST | COMPLAINT | PASSED | View |
TENANT ACCESS TO SERVICE | PROVIDE ACCESS. | 5103 W HURON ST | COMPLAINT | PASSED | View |
DEFECTIVE OUTLETS | NON-WORKING, BROKEN, PAINTED THROUGHOUT. | 5103 W HURON ST | COMPLAINT | PASSED | View |
DEFECTIVE FIXTURES | NON-WORKING, BROKEN, MISSING COVERS/GLOBES THROUGHOUT. | 5103 W HURON ST | COMPLAINT | PASSED | View |
SUPPORT FIXTURES | BASEMENT | 5103 W HURON ST | COMPLAINT | PASSED | View |
SECURE RACEWAY | BASEMENT | 5103 W HURON ST | COMPLAINT | PASSED | View |
SEE INSPECTOR COMMENTS | (18-27-570.8) PROVIDE GFCI PROTECTION FOR ALL KITCHEN COUNTERTOPS, BATHROOMS, EXTERIOR AND UNFINISHED BASEMENT. | 5103 W HURON ST | COMPLAINT | PASSED | View |
NO PLANS/PERMIT AT JOBSITE | 5103 W HURON ST | PERMIT | PASSED | View | |
REPAIR/REBUILD GARAGE OR SHED | GARAGE OPEN MORTAR, FRACTURE, SPALLING CONCRETE, DAMAGE NEW HANG DOOR, AND SAGGING LINTEL. | 5103 W HURON ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF APARTMENT, NO ENTRY- UNABLE TO VERIFY COMPLAINT SR150212529. | 5103 W HURON ST | COMPLAINT | FAILED | View |
(18-27-570.10) PROVIDE SMOKE AND CO DETECTORS. | 5103 W HURON ST | COMPLAINT | PASSED | View | |
NO PERMIT WIRING | FOR INSTALLATION AND ALTERATION OF BUILDING ELECTRICAL PREMISE WIRING. GUT REHAB WORK IN PROGRESS, INSTALLATION OF NEW ELECTRICAL CONDUITS AND WIRING. | 5103 W HURON ST | COMPLAINT | PASSED | View |
ADD RECEPTACLES | PROVIDE ADDTIONAL RECEPTACLES ALL ROOMS. | 5103 W HURON ST | COMPLAINT | PASSED | View |