The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
CARB MONOX DETECT IN RESID | BASEMENT AT FRONT UNIT AND AT WATER HEATER ROOM / CARON MONOXIDE DETETCTOR - MISSING. | 10044 S AVENUE M | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | BASEMENT / REAR DOOR IS BLOCKED WITH JUNK AND GARBAGE. DOOR IS IMPOSSIBLE TO USE IN AN EMERGENCY AT ITS CURRENT STATE. | 10044 S AVENUE M | COMPLAINT | FAILED | View |
1HR SEP-D.U. AND REST OF BLDG | BASEMENT CEILING AT WATER TANK ROOM - MISSING DRYWALL. | 10044 S AVENUE M | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | REAR YARD - JUNK BEING STORED. LARGE PILE OF BRICKS STORED AT NORTH SIDE OF YARD. | 10044 S AVENUE M | COMPLAINT | FAILED | View |
EXIT THROUGH BEDROOM/BATHROOM | BASEMENT UNIT / REAR EXIT THROUGH A BEDROOM. | 10044 S AVENUE M | COMPLAINT | FAILED | View |
PERMIT REQUIRED | WEST ELEVATION / 6 FOOT WOOD PRIVACY FENCE INSTALLED AT REAR OF YARD WITHOUT A PERMIT. PEMIT IS NOW REQUIRED. | 10044 S AVENUE M | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | REMOVE PARTITIONS AND FIXTURES INCLUDING PLUMBING AND ELECTRIC INSTALLED IN THE BASEMENT INSTALLED WITHOUT A PERMIT. | 10044 S AVENUE M | COMPLAINT | FAILED | View |
SAFE WORKING CONDITIONS | BASEMENT / ELECTRICAL BOXES - EXPOSED WIRES WITH SHODDY ELECTRICAL WORK COMPLETED. | 10044 S AVENUE M | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | BASEMENT AT WATER HEATER ROOM / SMOKE DETECTOR - MISSING. | 10044 S AVENUE M | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | WEST ELEVATION / 2 STORY WOOD PORCH / 2ND FLOOR BEAM - ROTTING AND HAS SCABBED WOOD HIDING BEAM'S CONDITION AND 4X4 USED AS SUPPORT INSTALLED AT 45* ANGLE. END BEAM CONSISTS OF SINGLE 2X8 USED TO SUPPORT ENCLOSED 2ND FLOOR DECK STRUCTURE. 4X4 COLUMN INSTALLED AT TOP OF 1ST FLOOR DECK. JOISTS - FASTENED WITH NAILS ONLY. UPPER ENDS OF STRINGERS - FASTENED WITH NAILS ONLY. GUARDRAILS - LOCATED AT 6X6 HALF LAP JOINT. 2ND FLOOR DECKING - ROTTING WITH HOLES. ALL RAILING SYSTEMS - FASTENED WITH NAILS ONLY. PLANS AND PERMIT REQUIRED TO REPLACE ENTIRE REAR PORCH STRUCTURE. SUBJECT TO FIELD INSPECTION AND APPROVAL. | 10044 S AVENUE M | COMPLAINT | FAILED | View |
PERFRM STRUCT ENGINEER REPAIRS | 1ST FLOOR DECK JOISTS HAVE SUFFERED FIRE DAMAGE AND ARE SINGED AND CHARRED. CITY OF CHICAGO REQUIRES A DETAILED AND COMPREHENSIVE STRUCTURAL ENGINEERS REPORT THAT ADDRESSES THE PROBLEM, ITS CAUSE AND POTENTIAL SOLUTIONS WITH FOCUS ON THE STRUCTURAL PER BUILDING CODE SECTION 34 ( 13-196-030 ) AND 34 ( 13-196-031 ) FOR CRITICAL EXAMINATION.IF THE PROFESSIONAL'S OPINION IS THAT THERE IS NO STRUCTURAL ISSUE, THEN SHE / HE NEEDS TO REPORT WHAT THE ACTUAL PROBLEM IS, WHY SHE / HE BELIEVES IT HAPPENED AND HAVE PHOTOGRAPHS TO SUPPORT THE OPINION. TWO COPIES SIGNED AND SEALED BY AN ILLINOIS LICENSED STRUCTURAL ENGINEER / ARCHITECT ARE TO BE SUBMITTED.WHEN A PROFESSIONAL DISAGREES WITH ANY VIOLATION, THAT PROFESSIONAL MUST PROVIDE PROOF AS WELL AS ACCEPT LIABILTY FOR THE VIOLATIONS RELATED TO HER / HIS PROFESSIONAL OPINION. | 10044 S AVENUE M | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | BASEMENT AT REAR / BEDROOM HAS BEEN ADDED. NEW ELECTRIC HAS BEEN RAN AT BASEMENT. MASONRY WALL AT BASEMENT HAS BEEN PARTIALLY REMOVED WITHOUT A PERMIT. SUBMIT PLANS AND OBTAIN PERMIT FOR ALL ALTERATIONS TO THE BUILDING OR RESTORE THE BUILDING TO THE ORIGINAL STATE. SUBJECT TO FIELD INSPECTION AND APPROVAL BY ALL RELATED TRADES. | 10044 S AVENUE M | COMPLAINT | FAILED | View |