Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-08-30 @ 4:59 PM
PIN: 20151040080000
Property Address: 5500 S UNIVERSITY AVE
City - Zip: CHICAGO - 60637
2023 Property Class: 590
2023 Township: 70 - Hyde Park
2023 Neighborhood: 70010
2023 Tax District: 70120
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 65 Violations
Violation Inspector Comments Address Category Status View
INSTALL SMOKE DETECTORS ALL 3 BUILDINGS, ALL STAIRWELLS TOP LEVEL - MISSING SMOKE DETECTORS. 5500 S UNIVERSITY AVE COMPLAINT FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA SMOKES HAVE TO BE TESTED 5500 S UNIVERSITY AVE PERMIT FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA ADDITIONAL CARS ON PERMIT ARE UNDER CONSTRUCTION 5500 S UNIVERSITY AVE PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA LABEL ALL MECHANICALS IN BOTH MACHINE ROOM AND PIT 5500 S UNIVERSITY AVE PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA ENCLOSE ALL WIRING IN HOISTWAY AND PIT 5500 S UNIVERSITY AVE PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA FIRE RATE THE HOISTWAY AND PLUG ALL OPENNINGS 5500 S UNIVERSITY AVE PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA PROVIDE DIVIDING MESH IN HOISWAY, BETWEEN ELEVATORS IN SHARED HOISTWAY. 5500 S UNIVERSITY AVE PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA PROVIDE FIRE RATED MACHINE ROOM DOORS 5500 S UNIVERSITY AVE PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA PROVIDE GFCI IN MACHINE ROOM 5500 S UNIVERSITY AVE PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA PROVIDE PROPER LIGHTING 15FC IN MACHINE ROOM. 5500 S UNIVERSITY AVE PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA PROVIDE SMOKES AND TEST ALL FAID'S 5500 S UNIVERSITY AVE PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA PROVIDE CONSTRUCTION PHONE AND COMMUNICATION LINE FOR OPERATOR INSIDE ELEVATOR 5500 S UNIVERSITY AVE PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA GROUT AND LEVEL SILLS TO PREVENY TRIP HAZARD 5500 S UNIVERSITY AVE PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA THIS ELEVATOR IS ONE OF SEVEN ON PERMIT #100623303 5500 S UNIVERSITY AVE PERMIT FAILED View
ARRANGE COMPLETED PERMIT INSP. 100646838 5500 S UNIVERSITY AVE PERMIT PASSED View
MAINTAIN OR REPAIR ELECT ELEVA PROVIDE FAID'S AND TEST FOR CARS 8. 9, & 10. 5500 S UNIVERSITY AVE PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA CAR 10, ENCLOSE ALL WIRING IN HOISTWAY AND PIT. 5500 S UNIVERSITY AVE PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA CAR 10, CLEAN PIT 5500 S UNIVERSITY AVE PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA CAR 10. PROVIDE GRATING OVER SUMP HOLE & SECURE 5500 S UNIVERSITY AVE PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA CAR 10. FIRE CAULK ALL OPENINGS IN HOISTWAY. REMOVE WOOD FROM TOP OF HOISTWAY 5500 S UNIVERSITY AVE PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA CAR 10, PROTECT MACHINE ROOM LAMPS 5500 S UNIVERSITY AVE PERMIT PASSED View
MAINTAIN OR REPAIR ELECT ELEVA CAR'S 8, 9 & 10. PROVIDE CAR/FLOOR DESIGNATION ON ALL FLOORS 5500 S UNIVERSITY AVE PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA MACHINE ROOM FOR 8, 9 & 10. INSTALL DRIP PANS WITH DRAIN, UNDER ALL HEATER LINES. 5500 S UNIVERSITY AVE PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA CAR 8, 9 & 10, INSTALL CROSS HEAD DATA TAGS 5500 S UNIVERSITY AVE PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA CAR'S 8, 9 & 10. INSTALL CONTROLLER DATA TAGS 5500 S UNIVERSITY AVE PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA INSTALL FIRE SERVICE KEY BOX IN LOBBY. 5500 S UNIVERSITY AVE PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA INSTALL LIGHTING AT TOP OF HOISTWAY. LIGHTING TO BE PROTECTED AND PRODUCE 19 FC. 5500 S UNIVERSITY AVE PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA CAR'S 8-10. INSTALL FIRE RATED MACHINE ROOM DOOR. 5500 S UNIVERSITY AVE PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA FIRE CAULK ALL OPENINGS IN MACHINE ROOM. 5500 S UNIVERSITY AVE PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA CAR 10, ENCLOSE ALL WIRING IN HOISTWAY AND PIT. 5500 S UNIVERSITY AVE PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA CAR'S 8, 9 & 10. INSTALL CONTROLLER CODE DATA TAGS 5500 S UNIVERSITY AVE PERMIT FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA REPAIR THE EMERGENCY POWER TO TRANSFER BACK TO NORMAL AUTOMATICALLY 5500 S UNIVERSITY AVE PERMIT PASSED View
MAINTAIN OR REPAIR ELECT ELEVA RE-PIPE CAR TOP ELECTRICAL TO PREVENT TRIP HAZARD. ELEVATORS 3,4,5 & 6. 5500 S UNIVERSITY AVE PERMIT PASSED View
MAINTAIN OR REPAIR ELECT ELEVA PROVIDE CODE DATA PLATE FOR #6 ELEVATOR 5500 S UNIVERSITY AVE PERMIT PASSED View
MAINTAIN OR REPAIR ELECT ELEVA REPAIR EMERGENCY POWER TO TRANSFER BACK TO NORMAL, AUTOMATICALLY 5500 S UNIVERSITY AVE PERMIT PASSED View
MAINTAIN OR REPAIR ELECT ELEVA RELOCATE SPRINKLER FROM PIT FLOOR TO BE 18IN ABOVE THE PIT FLOOR CARS 8 & 9 5500 S UNIVERSITY AVE PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA PROVIDE CODE COMPLIANT REINFORCED PIT LADDERS 8,9 & 10 AND NON SLIP LADDER RUNGS 5500 S UNIVERSITY AVE PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA PATCH ALL OPENNING IN MACHINE ROOMS FOR ALL ELEVATORS 5500 S UNIVERSITY AVE PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA 5500 S UNIVERSITY AVE PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA PROVIDE ELEVATOR ID, FOR EACH ELEVATOR ON ALL LANDINGS 5500 S UNIVERSITY AVE PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA PROVIDE ADDTIONAL GFCI LOCATION IN #5 AND #6 CONTROL SPACE MACHINE ROOM AND PROPER 19FC LIGTING 5500 S UNIVERSITY AVE PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA RELOCATE SPRINKLER FROM PIT FLOOR TO BE 18IN ABOVE THE PIT FLOOR 5500 S UNIVERSITY AVE PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA PROVIDE CODE COMPLIAT PIT LADDERS ALL CARS 5500 S UNIVERSITY AVE PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA PROVIDE ONE MOUNTED FIRE EXTINGUISHER PER ELEVATOR, INSIDE MACHINE/CONTROL SPACE ELEVATORS 3,4,5 AND 6 AND ADD'L ELEVATORS 5500 S UNIVERSITY AVE PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA PROVIDE METAL SHEAVES FOR ALL ELEVATORS 5500 S UNIVERSITY AVE PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA PROVIDE DRIP PANS UNDER WATER PIPES ALL ELEVATORS 5500 S UNIVERSITY AVE PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA PROVIDE COVER AND ENCLOSE ALL ELECTRICAL BOXES IN ALL MACHINE ROOM AND CONTROL SPACES 5500 S UNIVERSITY AVE PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA PROVIDE NON SLIP PIT LADDER RUNGS 5500 S UNIVERSITY AVE PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA PROVIDE ADDITIONAL RETAINING CLIP ON SHACKLE COUNTERWEIGHT SIDE FOR ELEVATOR 4 5500 S UNIVERSITY AVE PERMIT FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA REMOVE OR REROUTE COPPER PIPE ON PIT FLOOR ELEVATOR MACHINE ROOM 1 & 2 5500 S UNIVERSITY AVE PERMIT FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA PROVIDE DRAIN PAN FOR WATER PIPE IN ELEVATOR MACHINE ROOM 1 & 2 5500 S UNIVERSITY AVE PERMIT FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA PROVIDE CODE DATA PLATE ON CONTROLLERS 5500 S UNIVERSITY AVE PERMIT FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA PROVIDE MACHINE ROOM SIGNAGE 5500 S UNIVERSITY AVE PERMIT FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA PROVIDE MOUNTED MACHINE ROOM FIRE EXTINGUISHER CARS 1 & 2 5500 S UNIVERSITY AVE PERMIT FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA FIRE RATE AMD PATCH HOISTWAY OPENNINGS 1 & 2 5500 S UNIVERSITY AVE PERMIT FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA PROPERLY NUMBER ALL HOISTWAY LANDINGS INSIDE HOISTWAY FOR 1 & 2 5500 S UNIVERSITY AVE PERMIT FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA PROVIDE SUPPORT FOR TOP OF PIT LADDER 1 & 2 5500 S UNIVERSITY AVE PERMIT FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA PROVIDE A SEPARATE SINGLE OUTLET FOR SUMP PUMP 5500 S UNIVERSITY AVE PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA COMPLETE PHASE 2 FIRE SERVICE WHEN CARD READERS ARE ACTIVATED FOR ALL CARS. 5500 S UNIVERSITY AVE PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA PROVIDE A LEGIBLE PLAN DRAWING SHOWING ALL ELEVATOR LOCATIONS AND NUMBERS ON LOBBY PANEL 5500 S UNIVERSITY AVE PERMIT PASSED View
MAINTAIN OR REPAIR HYDRO ELEVA RE TEST PHASE 2 FIRE SERVICE WHEN CARD READER IS ACTIVATED FOR 1,2 AND 7 5500 S UNIVERSITY AVE PERMIT FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA PROVIDE PLAN DRAWING OF ELEVATORS FOR LOBBY PANEL. 5500 S UNIVERSITY AVE PERMIT PASSED View
ARRANGE COMPLETED PERMIT INSP. 5500 S UNIVERSITY AVE PERMIT PASSED View
OPEN 5500 S UNIVERSITY AVE PERMIT PASSED View
MAINTAIN OR REPAIR HYDRO ELEVA PROVIDE EMERGENCY POWER 1,2 AND 7 5500 S UNIVERSITY AVE PERMIT FAILED View