The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
HEAT UNIT ADEQUATELY | BEDROOM 2 TEMPERATURE IS 63 F. AT 3:00 PM.BATHROOM 2 TEMPERATURE IS 61 F. AT 3:05 PM.HEATING SYSTEM IS ON AT TIME OF INSPECTION. | 8454 S HALSTED ST | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | SMOKE DETECTOR MISSING. | 8454 S HALSTED ST | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | CARBON MONOXIDE DETECTOR MISSING. | 8454 S HALSTED ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | CLOUMNS SET ON CONCRETE BLOCK. FOUNDATION STATUS UNKNOWN. LEDGER BEAM ATTACHED TO EXTERIOR WALL WITH NAILS ONLY. STRINGERS SPLIT AND SCABBED. STRINGER ATTACHED TO COLUMNS WITH NAILS ONLY. DECK JOISTS ROTTEN AND SCABBED. RAIL SECTIONS ARE ONLY 36" HIGH. RAIL SECTIONS ATACHED TO COLUMNS, POSTS AND EXTERIOR WALLS WITH NAILS ONLY. PERMIT ONLY, NO PLANS REQUIRED TO REPLACE FRONT EXTERIOR STAIRS.REAR EXTERIOR STAIRS: STRINGERS ATTACHED TO EXTERIOR WALL AND POSTS WITH NAILS ONLY. BOTH STRINGERS SPLIT AT BOTTOM. TREAD DEPTH IS NOT UNIFORM: TREAD # 7 IS ONLY 7 1/2 " DEEP. RAIL SECTIONS ARE ONLY 34 " HIGH. RAIL SECTION S ATTACHED TO POSTS AND EXTERIOR WALL WITH NAILS ONLY. PERMIT ONLY, NO PLANS REQUIRED TO REPLACE REAR EXTERIOR STAIRS. | 8454 S HALSTED ST | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | WINDOWS BOARDED. | 8454 S HALSTED ST | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | JUNK AND DEBRIS: DISCARDED HOUSEHOLD ITEMS. | 8454 S HALSTED ST | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | SMOKE DETECTOR MISSING. | 8454 S HALSTED ST | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | CARBON MONOXIDE DETECTOR MISSING. | 8454 S HALSTED ST | COMPLAINT | FAILED | View |
EXPOSED WIRING | EXPOSED WIRES. | 8454 S HALSTED ST | COMPLAINT | FAILED | View |
COVER OUTLETS AND JBS | JUNCTION BOX COVER LOOSE. | 8454 S HALSTED ST | COMPLAINT | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | FURNACE AND HOT WATER HEATER INSTALLATION REQUIRE PERMIT. NO PERMIT ON FILE. | 8454 S HALSTED ST | COMPLAINT | FAILED | View |
CHIMNEY | REAR CHIMNEY: BROKEN BLOCKS. | 8454 S HALSTED ST | COMPLAINT | FAILED | View |
CHIMNEY CAPPING | CHIMNEY MISSING CAPPING. | 8454 S HALSTED ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR GRADE TO 1ST FLOOR WOODEN PORCH: COLUMNS RESTING ON SOIL SURFACE WITHOUT BASES - FOUNDATION STATUS UNKNOWN. STAIR SYSTEM LOOSE, SWAYING AND MISSING LANDING. NEWEL POST LOOSE AND BOWING. STRINGERS BROKEN.TREAD WIDTH ONLY 9" WIDE WITH MISSING RISER AT GRADE. FRONT GRADE TO 1ST FLOOR PORCH: COLUMNS ERECTED ON CONCRETE BLOCKS WITH BASE SINKING - FOUNDATION STATUS UNKNOWN. GUARDRAILS AND RAILING HEIGHTS ONLY 30" HIGH. DECK JOISTS ARE TOE-NAILED TO HEADER JOISTS THRU-OUT. STINGERS SPLITED AND SUPPORTED BY 2X4 WOODEN BOARDS AT MIDDLE. PLANS AND PERMIT REQUIRED TO REPAIR FRONT PORCH. PERMIT ONLY REQUIRED TO REPLACE REAR PORCH. | 8454 S HALSTED ST | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | FRONT SERVICE WALKS AND REAR CAR PORT WITH BROKEN CONCRETE. | 8454 S HALSTED ST | COMPLAINT | FAILED | View |
REPAIR GUTTER & DOWNSPOUT | DOWNSPOUT SUSPENDED 4' ABOVE THE GROUND WITH PORTIONS OF GUTTERS MISSING. | 8454 S HALSTED ST | COMPLAINT | FAILED | View |
RAT STOP AROUND EXTERIOR | REAR AT BASE - RAT HOLES. | 8454 S HALSTED ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BLDG: NO RESPONSE - UNVERIFIED DETECTORS AND CONDITIONS. | 8454 S HALSTED ST | COMPLAINT | FAILED | View |
NO POSTED ADDRESS | NO ADDRESS POSTED. | 8454 S HALSTED ST | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | MISSING OWNER'S I.D. SIGN. | 8454 S HALSTED ST | COMPLAINT | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | 6' METAL FENCE AND GATE INSTALLED WITHOUT A PERMIT. | 8454 S HALSTED ST | COMPLAINT | FAILED | View |
VACANT BUILDING - REGISTER | 8454 S HALSTED ST | COMPLAINT | CLOSED | View | |
OBTAIN OR POST PERMIT | 8454 S HALSTED ST | COMPLAINT | CLOSED | View | |
MAINTAN BLDG IN SAFE CONDITION | 8454 S HALSTED ST | COMPLAINT | CLOSED | View | |
REPAIR/WRECK DANGER RESID PREM | 8454 S HALSTED ST | COMPLAINT | CLOSED | View | |
VACANT BUILDING - REGISTER | 8454 S HALSTED ST | COMPLAINT | CLOSED | View | |
POST OWNER INFO ON ABDN BLDG | 8454 S HALSTED ST | COMPLAINT | CLOSED | View | |
WATCHMAN | 8454 S HALSTED ST | COMPLAINT | CLOSED | View | |
POST OWNER NAME OF VACNT BLDG | VIOLATION CLOSED PER PCR 1180 | 8454 S HALSTED ST | COMPLAINT | CLOSED | View |