The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR WINDOW SILLS | WINDOW SILLS-(SOUTH) WORN. (BEDROOM) LOOSE. | 4900 W FERDINAND ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | PARTIALLY ENCLOSED PORCH-STRINGERS ARE PULLING AWAY FROM THE HEADER BEAM CONNECTION. NORTH HANDRAIL PULLING AWAY FROM THE COLUMN CONNECTION. IMPROPER CONNECTIONS-MOST MEMBERS ARE ONLY TOE NAILED TOGETHER. (UNVERIFIED CONDITION OF ENCLOSED STRUCTURAL MEMBERS). ONLY PERMIT REQUIRED FOR REPAIRS. | 4900 W FERDINAND ST | COMPLAINT | FAILED | View |
PROVIDE GUTTER & DOWNSPOUT | DOWNSPOUT-MISSING. | 4900 W FERDINAND ST | COMPLAINT | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | CEILINGS-(KITCHEN AND NORTH BEDROOM) WATER DAMAGE. WALL- (1ST FLOOR) BROKEN DRYWALL. | 4900 W FERDINAND ST | COMPLAINT | FAILED | View |
SUBMIT STRUCT. ENG. RPT (INT.) | SUBMIT ENGINEER'S REPORT ON THE STABILITY OF THE FIRST FLOOR STRUCTURE (BEAMS, COLUMNS, JOISTS) AND ENTIRE BUILDING. | 4900 W FERDINAND ST | COMPLAINT | FAILED | View |
STRUCTURAL MEMBER, PIER BLOCK | ONLY TEMPORARY, ADJUSTABLE FLOOR JACKS, SET ON TOP OF WOODEN BLOCKS, RESTED ON THE BASEMENT FLOOR, SUPPORTING THE FIRST FLOOR, ARE UTILIZED TO SUPPORT ALL BEAMS. 2X8 MEMBERS ARE UTILIZED AS COLUMNS AND BEAMS FOR ADDITIONAL SUPPORT UNDERNEATH THE KITCHEN AREA. FRACTURED, OVERCUT FLOOR JOISTS. (DANGEROUS AND HAZARDOUS CONDITIONS) PLANS AND PERMIT REQUIRED FOR REPAIRS. | 4900 W FERDINAND ST | COMPLAINT | FAILED | View |
MAINTAIN WINDOW SASH | WINDOW SASHES-(SOUTH) UNABLE TO OPEN. (EAST) BROKEN. | 4900 W FERDINAND ST | COMPLAINT | FAILED | View |
REPAIR DOOR FRAME, MULLION | DOOR FRAME-BROKEN, SPLINTERED. | 4900 W FERDINAND ST | COMPLAINT | FAILED | View |
REPAIR DOOR HARDWARE | DOORS-BROKEN, LOOSE HINGES. | 4900 W FERDINAND ST | COMPLAINT | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | MISSING HANDRAIL. | 4900 W FERDINAND ST | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | SMOKE DETECTORS-MISSING. | 4900 W FERDINAND ST | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | CARBON MONOXIDE DETECTORS-MISSING. | 4900 W FERDINAND ST | COMPLAINT | FAILED | View |
DEFECTIVE OUTLETS | ELECTRICAL OUTLETS-LOOSE. | 4900 W FERDINAND ST | COMPLAINT | FAILED | View |
SUPPORT FIXTURES | CEILING FAN-LOOSE. | 4900 W FERDINAND ST | COMPLAINT | FAILED | View |
EXPOSED WIRING | EXPOSED WIRING. | 4900 W FERDINAND ST | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS (WORK IN PROGRESS) TO THE BASEMENT OR RESTORE THE BUILDING TO THE ORIGINAL STATE. | 4900 W FERDINAND ST | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | REMOVE ALL WOOD FRAMING FOR PARTITIONS, INCLUDING ELECTRIC, INSTALLED IN THE BASEMENT WITHOUT A PERMIT. (WORK IN PROGRESS) | 4900 W FERDINAND ST | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | WINDOW PANE-BROKEN. | 4900 W FERDINAND ST | COMPLAINT | FAILED | View |