The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
UNINTERRUPTED EXIT AT GRADE | SOUTH AREAWAY BLOCKED WITH PLYWOOD NO EGRESS | 341 S TRUMBULL AVE | PERIODIC | PASSED | View |
REPAIR WINDOW SILLS | ALL ELEVATION VARIOUS LOCATION OPEN MORTAR JOINTS | 341 S TRUMBULL AVE | PERIODIC | PASSED | View |
REPAIR ROOF | REAR PORCH NO HATCH COVERS ON ROOF OVERHEAD | 341 S TRUMBULL AVE | PERIODIC | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | REAR FENCE OVER (5) FEET PERMIT REQUIRED | 341 S TRUMBULL AVE | PERIODIC | PASSED | View |
SCREEN OUTER DOORS, WINDOWS | ALL ELEVATIONS VARIOUS LOCATIONS TORN AND MISSING SCREENS | 341 S TRUMBULL AVE | PERIODIC | FAILED | View |
INSTALL DOOR VIEWING DEVICE | NO PEEPHOLE IN ALL REAR DOORS | 341 S TRUMBULL AVE | PERIODIC | FAILED | View |
REPLACE D&H PORCH | REAR PORCH ENTIRE STRUCTURE DEFLECTS UNDER LOAD GRADE TO 3RD LEVEL IMPROPER SPLICE AND BOLT CONNECTION ON UPRIGHT RAILINGS LOOSE ALL LEVELS DEFLECTING UNDER LOAD TREADS UNDERSIZED NOT PURPOSELY ANCHORED INTO STRUCTURE UPRIGHT COLUMNS OUT OF PLUM LOOKOUT NOT IN POCKET NO MORTAR 4X4 CENTER SUPPORT COLUMNS FOR EACH DECK ON TOP OF RAILINGS NOT SUPPORT FOR (100 FT) PLANS AND PERMITS REQUIRED FOR REPAIR OR REPLACE REAR PORCH | 341 S TRUMBULL AVE | PERIODIC | PASSED | View |
PERMIT REQUIRED - CONTRACTOR | FRONT FENCE OVER 5' FEET TALL; OBTAIN PERMIT | 341 S TRUMBULL AVE | PERIODIC | PASSED | View |
OBSTRUCTIONS IN EXIT WAY | SOUTH ELEVATION: SERVICE WALKWAY BLOCKED BY PLYWOOD | 341 S TRUMBULL AVE | PERIODIC | PASSED | View |
REPAIR LINTELS | FRONT ELEVATION: LINTELS RUSTED, SAGGING | 341 S TRUMBULL AVE | PERIODIC | PASSED | View |
REPAIR WINDOW SILLS | FRONT ELEVATION: WINDOW SILLS- WASHED OUT MORTAR | 341 S TRUMBULL AVE | PERIODIC | PASSED | View |
REPAIR EXTERIOR WALL | NORTH ELEVATION AT LOWER LEVEL: WASHED OUT MORTAR | 341 S TRUMBULL AVE | PERIODIC | PASSED | View |
REPAIR EXTERIOR STAIR | REAR: MISSING HANDRAIL, GRADE TO BASEMENT | 341 S TRUMBULL AVE | PERIODIC | PASSED | View |
REPLACE D&H PORCH | REAR PORCH: POOR DESIGN, FOOTING STATUS UNKNOWN, 6X6 LOOKOUT BEAM SPANNED 13' FEET 2" INCHES, BOTH LOOKOUT AND 6X6 COLUMN ARE NOTCHED 2 1/2", WHICH LEAVES ONL 2 3/4" OF WOOD FOR SUPPORT, MIDLANDING ARE SUPPORTED BY 4X4 WHICH IS NOT SUPPORT AT GRADE LEVEL, TOPR OF STRINGERS ARE NOT SUPPORTED, MISSING BOLTS, ALSO POOR BEAM TO COLUMN CONNECTION, RAIL HEIGHT IS ON 37"; SUBMIT PLANS AND OBTAIN PERMIT FOR REPLACEMENT OF REAR PORCH | 341 S TRUMBULL AVE | PERIODIC | PASSED | View |
PARAPET | NORTH ELEVATION, PARAPET WALL: WASHED OUT MORTAR | 341 S TRUMBULL AVE | PERIODIC | PASSED | View |