Chicago Building Violations Data: 15 Violations
Violation Inspector Comments Address Category Status View
UNAPPROVED HEATING DEVICE APTS. 1R, 2F AND 2R / UNSING COOKING STOVES AS HEATING DEVICES. 7425 S HARVARD AVE COMPLAINT FAILED View
HEAT UNIT ADEQUATELY GAS SERVICE IS SHUT OFF, NO HEAT PROVIDED. APT. - 2F / ROOM TEMPERATURES : LIVING ROOM 70F, FRONT BEDROOM 61F AT 12:15 PM. HEATING SYSTEM IS OFF AT TIME OF INSPECTION, NO HEAT PROVIDED. 7425 S HARVARD AVE COMPLAINT FAILED View
SUPPLY HOT WTR MIN TEMP 120DEG GAS SERVICE - SHUT OFF, NO HOT WATER FURNISHED. APTS 1R, 2F, AND 2R / HOT WATER TEMPS. - 68F AT TIME OF INSPECTION. 7425 S HARVARD AVE COMPLAINT FAILED View
CARB MONOX DETECT IN RESID APT. - 1R / CARBON MONOXIDE DETECTOR - MISSING. 7425 S HARVARD AVE COMPLAINT FAILED View
INSTALL SMOKE DETECTORS APTS. - 1R, 2F, AND 2R / SMOKE DETECTORS - MISSING. 7425 S HARVARD AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM EAST ELEVATION / 2 STORY WOOD PORCH / COLUMN HALF LAP JINST - FASTENED WITH NAILS ONLY. BEAMS CONSIST OF SINGLE 2X8'S. DECK JOISTS - MEASURED UP TO 11 FEET 4 INCHES. DECK JOISTS JOISTS - CANILEVERED UP TO 3 FEET PAST BEAMS. JOISTS - FASTENED WITH NAILS ONLY. STAIR STRINGERS - FASTENED AT UPPER CONNECTIONS ONLY. PLANS AND PERMIT REQUIRED TO REPAIR OR REPLACE EAST 2 STORY WOOD PORCH. SUBJECT TO FIELD INSPECTION AND APPROVAL. 7425 S HARVARD AVE COMPLAINT FAILED View
ROACHES BUILDING - ROACHES THROUGHOUT. ROACH INFESTATION OBSERVED AT UNIT 2R. 7425 S HARVARD AVE COMPLAINT FAILED View
REPLACE D&H PORCH SOUTH ELEVATION / 2 STORY WOOD PORCH / COLUMNS -ERRECTED ON BROKEN CONCRETE BLOCKS. FOUNDATION STATUS - UNKNOWN. LEDGER BOARDS - PULLING AWAY FROM EXTERIOR WALLS AND HAVE 4X4 'S USED TO PROP UP DECKS. ENTIRE STRUCTURE IS DETERIORATED, WEAK AND AND USTABLE. PLANS AND PERMIT REUIRED TO REPLACE DANGEROUS AND HAZARDOUS SIDE 2 STORY WOOD PORCH. 7425 S HARVARD AVE COMPLAINT FAILED View
MICE/RODENTS BUILDING - MICE THROUGHOUT. MICE DROPPINGS - OBSERVED AT 2F AND 2R. NUMEROUS RODENT HOLES - OBSERVED THROUGHOUT. 7425 S HARVARD AVE COMPLAINT FAILED View
REPAIR EXTERIOR DOOR FRAME APT. - 2F / SIDE EXTERIOR DOOR FRAME - LARGE GAPS AT TOP AND SIDE. 7425 S HARVARD AVE COMPLAINT FAILED View
PLANS & PERMITS REQUIRED 2 UNIT BUILDING HAS BEEN CONVERTED AND IS NOW BEING USED AS A 4 UNIT BUILDING INCLUDING ADDING EXIT DOORS WHERE WINDOWS ONCE WERE LOCATED. SUBMIT PLANS AND OBTAIN PERMIT FOR ALL REALTED WORK TO 1ST AND 2ND FLOOR APARTMENTS OR RESTORE THE BUILDING TO THE ORIGINAL STATE. 7425 S HARVARD AVE COMPLAINT FAILED View
STOP/REMOVE NUISANCE SOUTH ELEVATION / STORING CARDBOARD BOXES UNDER 1ST FLOOR DECK ( RAT HARBORAGE ). 7425 S HARVARD AVE COMPLAINT FAILED View
INT WALL/CEILING CHIP PLASTER APTS. - 1R AND 2R / CEILINGS - WATER DAMAGE WITH BLACK SUBSTANCE OBSERVED. 7425 S HARVARD AVE COMPLAINT FAILED View
REPLCE WINDOW PANES, PLEXGLAS WEST ELEVATION / 2ND FLOOR WINDOW - CRACKED PANE. 7425 S HARVARD AVE COMPLAINT FAILED View
REPLACE D&H PORCH SOUTH TWO STORY OPEN WOOD PORCH WITH ROOF IS IMMINENTLY DANGEROUS AND HAZARDOUS -(1) ALL WOOD IN VARYING STAGES OF ROTT WITH JOINTS PULLING CREATING GAPS THAT EXPOSE RUSTING NAILS(2) JOIST HANGERS AND BOLTED CONNECTIONS MISSING(3) COLUMNS BEAR ON CONCRETE BLOCKS WITH UNKNOWN FOUNDATIONS(4) STAIR HANDRAILS AND GUARDRAILS ARE WEAK AND MOVES WHEN GRABBED(5) STAIR BETWEEN GROUND AND 1ST FLOOR - SOME MISSING RISER BOARDS(6) STRINGERS BOLTED CONNECTIONS TO POST, COLUMNS AND RIM JOIST ARE MISSING(7) JOIST ARE UNDERSIZED AND OVERSPANNED(8) PLANS AND PERMITS REQUIRED 7425 S HARVARD AVE COMPLAINT FAILED View