The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
CHIMNEY CAPPING | OPEN MORTAR JOINTS AT CHINMEY CAP | 1224 N CICERO AVE | PERIODIC | PASSED | View |
REPAIR PORCH SYSTEM | 2 REAR PORCHES (EAST & WEST) WEST PORCH METAL COLUMNS NO FOOTINGS, UNDERSIZED JOIST & BEAMS & RAILS, ROTTED DECKING SCABBING & BLOCKING AT STAIR STRINGERS & TREADS, WEST COLUMN LEANING AT TOP. EAST PORCH UNDERSIZED JOIST MISSING FOOTINGS AT METAL COLUMNS, UNDERSIZED RAILS SCABBING & BLOCKING AT STAIR STRINGER & TREADS ROTTED DECKING, WESTT COLUMN, STACKED, NO BOLTS IN HALF LAP, SCABBING AT COLUMN. ROACHES DOES NOT MEET CURRRENT CITY OF CHICAGO BUILDING CODE. | 1224 N CICERO AVE | PERIODIC | PASSED | View |
SUBMIT 2 COPY STRUCTURAL RPT | PROVIDE STRUCTURAL ENGINEERS REPORT FOR PORCH REPAIRS (2 PORCHES) | 1224 N CICERO AVE | PERIODIC | PASSED | View |
CARB MONOX DETECT IN RESID | APARTMENT 2W & 3E MISSING CARBON MONOXIDE DETECTOR | 1224 N CICERO AVE | PERIODIC | FAILED | View |
INSTALL DOOR VIEWING DEVICE | ALL APARTMENT DOORS MISSING PEEPHOLES | 1224 N CICERO AVE | PERIODIC | FAILED | View |
SAFE WORKING CONDITIONS | APARTMENT 3E HEATING APARTMENT WITH KITCHEN STOVE & OVEN | 1224 N CICERO AVE | PERIODIC | PASSED | View |
RATS | HOLES THROUGH OUT PROPERTY RAT HARBORAGE | 1224 N CICERO AVE | PERIODIC | PASSED | View |
PERMIT REQUIRED - CONTRACTOR | PROVIDE PERMIT FOR PORCH REPAIR | 1224 N CICERO AVE | PERIODIC | PASSED | View |
NOTIFY DOB, USE OF VACANT LND | 1ST FLOOR STORE IS VACANT & SECURE | 1224 N CICERO AVE | PERIODIC | PASSED | View |
DEFECTIVE FIXTURES | REAR DEFECTIVE LIGHT FIXTURE | 1224 N CICERO AVE | PERIODIC | PASSED | View |
INSTALL SMOKE DETECTORS | FRONT HALL 3RD FLOOR DEFECTIVE SMOKE DETECTOR | 1224 N CICERO AVE | PERIODIC | PASSED | View |
FILE BLDG REGISTRATION | FAILED TO FILE BUILDING FOR 2006. | 1224 N CICERO AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO BASEMENT STORE FRONT & SOME UNITS | 1224 N CICERO AVE | PERIODIC | PASSED | View |
FILE BLDG REGISTRATION | NOT REGISTERED 2006/2007 | 1224 N CICERO AVE | PERIODIC | PASSED | View |
CHIMNEY CAPPING | OPEN MORTAR JOINTS AR CHIMNEY CAP | 1224 N CICERO AVE | PERIODIC | PASSED | View |
REPAIR PORCH SYSTEM | 2 REAR PORCHES (EAST & WEST), WEST PORCH: METAL COLUMNS MISSING FOOTINGS, UNDERSIZED JOIST (2X8 OVER 10'), UNDERSIZED BEAMS (2X8 OVER 10'), GUARD RAILS AT 36", UNDERSIZED, ROTTED DECKING, SCABBING & BLOCKING AT STAIR TREADS & STRINGERS, WEST COLUMN LEANING AT TOP; EAST PORCH: 2X8 OVER 10'-UNDERSIZED, UNDERSIZED BEAMS, 2X8 OVER 10', MISSING FOOTINGS; PROVIDE PLANS & PERMITS TO REPAIR PORCHES | 1224 N CICERO AVE | PERIODIC | PASSED | View |
CARB MONOX DETECT IN RESID | APT. 2W & 3E: MISSING CARBON MONOXIDE DETECTOR | 1224 N CICERO AVE | PERIODIC | PASSED | View |
INSTALL DOOR VIEWING DEVICE | ALL APT. DOORS: MISSING PEEPHOLES | 1224 N CICERO AVE | PERIODIC | PASSED | View |
INSTALL SMOKE DETECTORS | FRONT HALL, 3RD FL: DEFECTIVE SMOKE DETECTOR | 1224 N CICERO AVE | PERIODIC | PASSED | View |
STRUCTURAL MEMBER, PIER BLOCK | NORTHEAST CORNER COLUMN, DANGEROUS & HAZARDOUS, CORNER BRICK COLUMN WHICH SUPPORTS STEEL THAT IS CARRYING UPPER FLOOR JOIST & BRICK WORK ABOVE IS SEVERELY DAMAGED DUE TO AUTO ACCIDENT. | 1224 N CICERO AVE | PERIODIC | PASSED | View |
SUBMIT 2 COPY STRUCTURAL RPT | PROVIDE AT STRUCTURAL ENGINEER'S REPORT FOR CORNER COLUMN (NORTHEAST COLUMN) REPAIR, TEMPORARY SUPPORT OF UPPER FLOORS DURING CONSTRUCTION & STRUCTURAL STABILITY OF BUILDING INCLUDES PERMIT FOR WORK & PERFORM WORK PER APPROVED ENGINEER'S REPORT (APPROVED BY DCAP) | 1224 N CICERO AVE | PERIODIC | PASSED | View |
FILE BLDG REGISTRATION | BUILDING - NOT REGISTERED FOR 2006 AND 2007 | 1224 N CICERO AVE | PERIODIC | PASSED | View |
INSTALL SMOKE DETECTORS | NO SMOKE DETECTORS IN THE FRONT STAIRWELL. | 1224 N CICERO AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | THE FRONT ENTRY DOOR HAS SHATTERED SIDE LITES THAT ARE BOARDED. THIS DOOR HAS A BROKEN SELF CLOSER AND NO LOCK HARDWARE. | 1224 N CICERO AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | SOUTH & WEST ELEVATION: WASHED OUT MORTAR | 1224 N CICERO AVE | PERIODIC | PASSED | View |
CHIMNEY | WASHED OUT MORTAR AT CHIMNEY | 1224 N CICERO AVE | PERIODIC | PASSED | View |
REPAIR EXTERIOR WALL | SOUTH & WEST ELEVATION WASHED OUT MORTAR THRU-OUT | 1224 N CICERO AVE | PERIODIC | PASSED | View |
CHIMNEY | WASHED OUT MORTAR AT CHIMNEY | 1224 N CICERO AVE | PERIODIC | PASSED | View |