Chicago Building Violations Data: 14 Violations
Violation Inspector Comments Address Category Status View
POST OWNER/MANAGERS NAME/# POST OWNERSHIP / MANAGEMENT SIGN MISSING ADDRESS. 941 E 52ND ST COMPLAINT FAILED View
MAINTAIN WINDOW ALL ELEVATION BASEMENT WINDOW FRAMES / ROTTED, DAMAGED AND LOOSE. 941 E 52ND ST COMPLAINT FAILED View
DEBRIS, EXCESSIVE SOUTH GRADE TO BASEMENT 941 GARBAGE AND TRASH IN FRONT OF BASEMENT DOOR. 941 E 52ND ST COMPLAINT FAILED View
REPAIR EXTERIOR STAIR BOTH EXTERIOR STAIR GRADE TO BASEMENT MISSING GUARDRAIL AND HANDRAIL. 941 E 52ND ST COMPLAINT FAILED View
REPLACE D&H PORCH REAR PORCH 943-45 / CONCRETE FOOTING CRACKED AND SETTLED. BOLTS ON LEDGER UNDERSIZED JOIST ON 2ND FLOOR NOT SPLICED ON 6X6 BEAM. RIM JOIST ROTTED, NO JOIST HANGERS, JOIST TOE-NAILED. 1ST FLOOR SHIMS BETWEEN COLUMN AND BEAMS, OPEN BEAM POCKET THRU-OUT AND CAULKED AT FIRECUT AND ROTTEN, COLUMN ROTTED AND OVER-NOTCHED. HAND AND GUARD RAILS TOO SHORT, LOOSE AND DAMAGED, MISSING PICKETS. RISER AND TREADS DAMAGED AND ROTTED, STRINGER OVERCUT, DECKBOARD WEAK PORCH SWAYS AT LANDING (D & H POSTED). 941 - NO FOOTING, COLUMN SITTING ON SIDEWALK. BOLTS UNDERSIZED, NO JOIST HANGER UNDER LANDINGS RIM JOIST AT 3RD FLOOR ROTTED. BEAM TO COLUMN CONNECTION (BUTT JOINT) WOOD COVERING CONNECTION NO "L" BRACKET. COLUMN BOWED. 1ST FLOOR PICKET MISSING FROM HANDRAIL, (REPAIR PERMIT NEEDED). 941 E 52ND ST COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION REFUSE ENTRY. 941 E 52ND ST COMPLAINT PASSED View
FLAKY INTERIOR PAINT BASEMENT WINDOW FLAKING PAINT. 941 E 52ND ST COMPLAINT PASSED View
REPUTTY WINDOW PANES BASEMENT WINDOWS MISSING AND DRIED OUT PUTTY. 941 E 52ND ST COMPLAINT PASSED View
CUT OR REMOVE HIGH WEEDS REAR HIGH WEEDS. 941 E 52ND ST COMPLAINT PASSED View
REPAIR EXTERIOR WALL FRONT BRICK FRACTURES. 941 E 52ND ST COMPLAINT PASSED View
PROVIDE GUARD RAIL 42 IN HIGH REAR BASEMENT STAIRS 1 GUARDRAIL MISSING, OTHER GUARDRAIL LOOSE. 941 E 52ND ST COMPLAINT PASSED View
STOP/REMOVE NUISANCE REAR BASEMENT STAIRS GARBAGE ACCUMULATION. 941 E 52ND ST COMPLAINT PASSED View
REPAIR GUTTER & DOWNSPOUT REAR DOWNSPOUT DISCONNECTED. 941 E 52ND ST COMPLAINT PASSED View
REPLACE D&H PORCH 2 EXTERIOR WOOD PORCH SYSTEMS - 945 - LEDGERS ROTTED NO BOLTS. JOIST ROTTED AND SCABBED MISSING HANGERS, BEAMS - PULLING WAY OPEN POCKETS INADEQUATE BEAM TO COLUMN CONNECTION. COLUMNS ROTTED, BUTT JOINTED TOE NAILED, MORE DETAILED AT LANDING. RAILINGS - NO BOLTS, LOW GUARDRAIL BELOW 42", ROTTED EVERYTHING TOE NAILED STAIRS. ROTTED TREADS, RISERS, UNEVEN RISER HEIGHTS AND TREAD DEPTH. DECKING LANDING SWAYS. 941 -FOUNDATION SMALL PILE OF CONCRETE, LEDGERS NO BOLTS. JOIST MISSING HANGERS. BEAMS FIRE CUT CONNECTIONS TO COLUMN, STRAPS FROM BRICK NOT CONNECTED TO BEAM. COLUMNS LAP JOINT TOO BOLTS. RAILING NO BOLTS TOE NAILED EXCESSIVE SPACING BETWEEN STAIRS AND GUARDRAIL. LANDING CANTILEVER STYLE. BOTH PORCHES REQUIRE PLANS AND PERMIT TO REPLACE OR REPAIR. DANGEROUS AND HAZARDOUS POST 6.21. BY MAYES. 941 E 52ND ST COMPLAINT PASSED View