Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
HEAT UNIT ADEQUATELY | LIVINGROOM 53 DEGREES | 632 N AVERS AVE | COMPLAINT | FAILED | View |
UNAPPROVED HEATING DEVICE | BEDROOM 51 DEGREES, BATHROOM 56 DEGREES, KITCHEN 63 DEGREES | 632 N AVERS AVE | COMPLAINT | FAILED | View |
SCREEN OUTER DOORS, WINDOWS | ALL ELEVATIONS AND LEVELS SEVERAL WINDOW AND DOOR SCREENS MISSING. | 632 N AVERS AVE | COMPLAINT | FAILED | View |
MAINTAN BLDG IN SAFE CONDITION | VACANT AND NOT SECURE BUILDING ALL REAR DOORS OPEN BUILDING VANDALIZED. | 632 N AVERS AVE | COMPLAINT | FAILED | View |
POST OWNER INFO ON ABDN BLDG | MISSING MANAGEMENT INFORMATION. | 632 N AVERS AVE | COMPLAINT | FAILED | View |
REPAIR CORNICE | EAST METAL CORNICE SECTION IS LOOSE AND WASHER OUT MORTAR BEHIND CORNICE. | 632 N AVERS AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | SOUTH ELEVATION WASHED OUT MORTAR. | 632 N AVERS AVE | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | FRONT AND REAR YARD AND BASEMENT JUNK AND REFUSE. | 632 N AVERS AVE | COMPLAINT | FAILED | View |
CUT OR REMOVE HIGH WEEDS | FRONT AND REAR YARDS WEEDS OVER 2'-0. | 632 N AVERS AVE | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | SERVICE WALK CRACKED CONCRETE UNEVEN. | 632 N AVERS AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | WEST PORCH UNDERSIZED 6X6 BEAMS AND 2'X8" JOISTS FOR 9'-2" AND 9'-6" SPAN. COLUMN BEAM CONNECTION ARE LIGHT METAL ROOF EXPOSED WOOD 6X6 BEAM SAGGING - PROVIDE PLANS AND PERMIT TO REPAIR. | 632 N AVERS AVE | COMPLAINT | FAILED | View |
REPAIR FENCE | WEST FENCE BROKEN SECTIONS. | 632 N AVERS AVE | COMPLAINT | FAILED | View |
REMOVE STAGNANT WATER BSMT | BASEMENT STAGNANT WATER BUSTED PIPE. | 632 N AVERS AVE | COMPLAINT | FAILED | View |
NO KEY TO USE EXIT DOOR | EAST FENCE GATES DOUBLE KEYLOCK. | 632 N AVERS AVE | COMPLAINT | FAILED | View |
SAFE WORKING CONDITIONS | DININGROOM 55 DEGREES | 632 N AVERS AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | 06-00807679 NO SIGN POSTED | 632 N AVERS AVE | COMPLAINT | CLOSED | View |
NO KEY TO USE EXIT DOOR | EAST GATES | 632 N AVERS AVE | COMPLAINT | CLOSED | View |
SERVICE WALK, PASSAGE, AREAWAY | SOUTH AND WEST BROKEN / MISSING CONCRETE | 632 N AVERS AVE | COMPLAINT | CLOSED | View |
MAINTAIN PROJECTIONS | EAST ABOVE 2 - PROJECTION RUSTED AND SEPARATED FROM WALL - PARTIALLY COLLASPED HANGING IN DANGEROUS AND HAZARDOUS MANNER NOT SECURED | 632 N AVERS AVE | COMPLAINT | CLOSED | View |
DEMO DEBRIS | EAST YARD DEBRIS FROM PARTIALLY COLLASPED PROJECTION | 632 N AVERS AVE | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR WALL | EAST AT PROJECTION OPEN JOINTS / LOOSE BRICK SOUTH WASHED OUT MORTAR | 632 N AVERS AVE | COMPLAINT | CLOSED | View |
PARAPET | NORTHWEST CORNER OPEN JOINTS WITH LOOSE BRICK | 632 N AVERS AVE | COMPLAINT | CLOSED | View |
REPAIR ROOF | ROOF OVER REAR PORCH 6X6 BEAM SPANNING 9' WITH EXCESSIVE AND DANGEROUS SAG ALSO SAGGING ROOF JOISTS NO APPROPRIATE COVERING OVER PLYWOOD DECK | 632 N AVERS AVE | COMPLAINT | CLOSED | View |
REPAIR FENCE | REAR YARD BROKEN / MISSING SECTIONS OF FENCING | 632 N AVERS AVE | COMPLAINT | CLOSED | View |
NOTIFY DOB, USE OF VACANT LND | 2ND FLOOR VACANT | 632 N AVERS AVE | COMPLAINT | CLOSED | View |
REPAIR DEFECTIVE FOUNDATION | REAR PORCH NORTHWEST COLUMN ON STONE | 632 N AVERS AVE | COMPLAINT | CLOSED | View |
REPAIR PORCH SYSTEM | REAR PORCH 2X8 JOISTS SPANNING 10'-2" AND 11', 6X6 BEAMS SPANNING 9' WITH NO VISIBLE TIE STRAPS AND OPEN BEAM POCKETS, 2X8 ACTING AS BEAM SPANNING 9' AND FACE NAILED TO COLUMN WITH NO SUPPORT AT COLUMN, NO BOLTS AT STAIR STRINGER CONNECTIONS | 632 N AVERS AVE | COMPLAINT | CLOSED | View |
PLANS & PERMITS REQ - CONTRCTR | FOR REPAIRS TO REAR PORCH AND ROOF OVER REAR PORCH PREVIOUSLY BUILT WITHOUT PERMITS / FOR INSTALLATION OF FURNACE SYSTEM IN BUILDING / FOR INSTALLATION OF FENCE OVER 5"-1" SURROUNDING PROPERTY / FOR INSTALLATION OF PARTITIONS FORMING WALLS IN BASEMENT TO FORM LIVING SPACE - ORIGINAL STORAGE / HEATING SPACE | 632 N AVERS AVE | COMPLAINT | CLOSED | View |
DEBRIS, EXCESSIVE | REAR YARD JUNK AND GARBAGE | 632 N AVERS AVE | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR DOOR SILL | EAST ENTRANCE DOOR LOOSE SILL AT DOOR | 632 N AVERS AVE | COMPLAINT | CLOSED | View |
PARAPET | NORTHWEST PARAPET WASHED OUT MORTAR. | 632 N AVERS AVE | COMPLAINT | FAILED | View |