The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPLCE WINDOW PANES, PLEXGLAS | THIS COMMERCIAL SPACE HAS A LARGE PLATE GLASS STORE FRONT WINDOW THAT IS SEVERELY FRACTURED. THERE IS AN IMMINENT HAZARD OF THIS HEAVY GLASS FURTHER FRACTURING AND FALLING ONTO THE PUBLIC SIDEWALK. DANGEROUS AND HAZARDOUS.SECTION 14X-3-301 | 4827 W IRVING PARK RD | COMPLAINT | FAILED | View |
ARRANGE FOR REINSPECTION REGAR | THIS INSPECTION WAS CONDUCTED BY THE DOB WITH THE DOB COMMISHONER PRESENT AS WELL ALONG WITH BACP AND CPD. THIS IS AN UNLICENSED SOCIAL CLUB. WE SPOKE WITH NUMEROUS PEOPLE OUTSIDE WHO SELF IDENTIFIED AS "CLUB MEMBERS" WHO WERE ATTEMPTING TO GAIN ENTRY WITH THEIR KEY CARDS BUT WERE UNABLE TO DO SO BECAUSE THE KEY CARD PAD'S POWER WAS CUT BY MEMBERS INSIDE WHO WERE VIEWING THE SCENE OUTSIDE VIA VIDEO CAMERA. THIS CLUB WAAS ISSUED NUMEROUS TICKETS 1 YEAR AGO BY BACP. THEY HAVE RE-OPENED WITHOUT ANY LICENSE OR ZONING AUTHORIZATION.SECTION 14A-1-104.7 AND 14A-1-104.13 | 4827 W IRVING PARK RD | COMPLAINT | FAILED | View |
CORD TO FIXTURE | REMOVE ALL NON APPROVE SPLICE CORD TO CAN LIGHT FIXTURE THROUGHOUT THE BAR AREAS DANGEROUS AND HAZARDOUS CONDITION | 4827 W IRVING PARK RD | COMPLAINT | FAILED | View |
INSTALL GFCI'S | PROVIDE GFCI PROTECTION FOR ALL BAR COUNTERTOP AREAS | 4827 W IRVING PARK RD | COMPLAINT | FAILED | View |
INSTALLATION OF ELECTRICAL CONDUIT BOXES WIRING DEVICES AND ELECTRICAL EQUIPMENT INSTALLED THROUGH THE 4827 & 4831 AREAS WITHOUT ROUGH INSPECTION ROUGH INSPECTION REQUIRES THAT ALL WALLS AND CEILINGS BE OPEN FOR ROUGH INSPECTION 14A-5-505.2 | 4827 W IRVING PARK RD | COMPLAINT | FAILED | View | |
REPLCE WINDOW PANES, PLEXGLAS | FRONT WINDOW BOARDED AND BROKEN 14X-3-303.13 | 4827 W IRVING PARK RD | COMPLAINT | FAILED | View |
VENT SYSTEM TO PRVNT BACK PRES | PROVIDE VENTS FOR ALL OF THE APPROPRIATE PLUMBING FIXTURES THAT IS MISSING VENTS | 4827 W IRVING PARK RD | COMPLAINT | FAILED | View |
UNKNOWN PROVIDE A WATER MAIN GROUND CONDUIT CONDUCTOR TO WITHIN 5' OF WATER METER OR VALVE 14E-2-250.68 C1 | 4827 W IRVING PARK RD | COMPLAINT | FAILED | View | |
SOIL/WASTE,VENT PIPE MATRL | REMOVE ALL PVC DRAIN PIPE AT LAVATORIES BAR SINKS AND THREE COMPARTMENTS SINK | 4827 W IRVING PARK RD | COMPLAINT | FAILED | View |
INSTALL COVERS | PROVIDE PROPER TYPE COVERS FOR RECEPTACLES MISSING COVERS AND IMPROPER TYPE COVERS THROUGHOUT THE BAR AREAS | 4827 W IRVING PARK RD | COMPLAINT | FAILED | View |
PROVIDE | PROVIDE MIXING VALVE FOR ALL LAVATORIES THROUGHOUT THE ENTIRE PREMISES 18-29-607.1.1 | 4827 W IRVING PARK RD | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR HARDWARE | REAR DOOR 4831 PANIC HARDWARE BROKEN DANGEROUS AND HAZARDOUS 14X-3-303.13 | 4827 W IRVING PARK RD | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS STRUCTURAL DETAIL FOR ROOF (DIVIDING WALL REMOVED) MULTIPLE ROOMS CONSTRUCTED WINDOWS BLOCKED GLASS BLOCK AND BRICK 2 DROPPED CEILING REAR DOOR 32" 4831 EGRESS BLOCKED FRONT 4827 FLOOR AT REAR EXCESSIVE SLOPE FIRE SEPARATION HVAC WORK AND USE OF OCCUPANCY 14A-4-401.1 | 4827 W IRVING PARK RD | COMPLAINT | FAILED | View |
LICENSED BONDED PLMBG CONTRCTR | OBTAIN LICENSE PLUMBING CONTRACTOR | 4827 W IRVING PARK RD | COMPLAINT | FAILED | View |
REPAIR FLOOR | INTERIOR TOWARDS REAR EXIT EXCESSIVE SLOPE CAUSING TRIP HAZARD DANGEROUS AND HAZARDOUS 14X-3-304.4 | 4827 W IRVING PARK RD | COMPLAINT | FAILED | View |
PRV BALLCOCK,VB,OR AIR GAP | PROVIDE VACUUM BREAKERS FOR ELEVATED WATER HEATERS FOR BOTH SET OF WASHROOMS UNABLE TO VERIFY | 4827 W IRVING PARK RD | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | MISSING CARBON MONOXIDE DETECTORS DANGEROUS AND HAZARDOUS 14X-5-504.9 | 4827 W IRVING PARK RD | COMPLAINT | FAILED | View |
DEFECTIVE OUTLETS | REPLACE ALL PAINTED RECEPTACLES THROUGH OUT THE BAR AREAS | 4827 W IRVING PARK RD | COMPLAINT | FAILED | View |
NEED THE ENTIRE DROP CEILING AREA OPEN SO THERE CAN BE A COMPLETE INSPECTION ABOVE THE ENTIRE DROP CEILING AREAS 14E-1-110.3 | 4827 W IRVING PARK RD | COMPLAINT | FAILED | View | |
ADD RECEPTACLES | ADD RECEPTACLES TO EASE EXTENSION CORD USE THROUGHOUT THE CEILING AREAS,ABOVE DROP CEILING AREAS BAR COUNTER TOP AREAS,TV AREAS DANGEROUS AND HAZARDOUS CONDITION | 4827 W IRVING PARK RD | COMPLAINT | FAILED | View |
SUPPORT FIXTURES | REPLACE ALL LIGHT FIXTURES BEING SUPPORTED BY ALTERED SPLICE CORD THAT PLUG INTO CEILING CAN LIGHTS AND CORDS PLUG INTO CAN LIGHTS FOR POOL TABLE LIGHTS DANGEROUS AND HAZARDOUS CONDITION | 4827 W IRVING PARK RD | COMPLAINT | FAILED | View |
FIRE EXTNGSHR REQ, NONRESDNTL | MISSING FIRE EXTINGUISHES THROUGHOUT DANGEROUS AND HAZARDOUS 14X-5-504.5 | 4827 W IRVING PARK RD | COMPLAINT | FAILED | View |
SUPPORT OUTLET AND BOX | SUPPORT JUNCTION BOX AND RECEPTACLE WITH EXPOSE WIRING AT EAST WALL AREA BY SMALL BAR COUNTER TOP AREA DANGEROUS AND HAZARDOUS CONDITION | 4827 W IRVING PARK RD | COMPLAINT | FAILED | View |
POST FLOOR PLAN DIAGRAM | MISSING EXIT DIAGRAM DANGEROUS AND HAZARDOUS 14A-8-804.1 | 4827 W IRVING PARK RD | COMPLAINT | FAILED | View |
OBTN PERMIT FOR PLUMBING WORK | OBTAIN PLUMBING PERMIT | 4827 W IRVING PARK RD | COMPLAINT | FAILED | View |
PROVIDE OPEN FRONT TOILET SEAT | NEED OPEN FRONT TOILET SEAT FOR ALL TOILETS THROUGHOUT THE ENTIRE PREMISES | 4827 W IRVING PARK RD | COMPLAINT | FAILED | View |
PRV WATER PIPES PROPER SIZE | PROVIDE PROPER SIZE WATER PIPING TO FIXTURES CURRENTLY 1/2" SIZED WATER PIPING IS SUPPLYING MULTIPLE WATER FIXTURES | 4827 W IRVING PARK RD | COMPLAINT | FAILED | View |
REPAIR ROOF | ROOF EVIDENCE OF WATER PENETRATION (WATER DAMAGED TILES) 14X-303.1.1 | 4827 W IRVING PARK RD | COMPLAINT | FAILED | View |
CEILING SUPPORT WIRES AND CEILING GRIDS SHALL NOT BE USE FOR SUPPORT PROPERLY SUPPORT ALL CAN LIGHTS AND 2X4 LAY IN LIGHT FIXTURES 14E-3-300.11 | 4827 W IRVING PARK RD | COMPLAINT | FAILED | View | |
OBSTRUCTIONS IN EXIT WAY | REAR DOOR 4831 DOOR WIDTH 32" UNDER SIZED DANGEROUS AND HAZARDOUS 14X-505.1.2 | 4827 W IRVING PARK RD | COMPLAINT | FAILED | View |
PROVIDE AIR CHAMERS | PROVIDE AIR CHAMBERS FOR ALL PLUMBING FIXTURES UNABLE TO VERIFY | 4827 W IRVING PARK RD | COMPLAINT | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | MULTIPLE CEILING TILES WATER DAMAGED CEILING GRID NOT SECURE DRYWALL CEILING ABOVE DROP CEILING NOT SECURE DANGEROUS AND HAZARDOUS 14X-3-304.3 | 4827 W IRVING PARK RD | COMPLAINT | FAILED | View |
POST APPROVED OCCUPANCY CARD | MISSING OCCUPANCY PLACARD 14A-8-802 | 4827 W IRVING PARK RD | COMPLAINT | FAILED | View |
PROVIDE | PROVIDE PROPER BACKFLOW DEVICE ICE MAKING MACHINE 18-29-608.1 | 4827 W IRVING PARK RD | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | REMOVE ALL PARTITIONS AND FIXTURES (INCLUDING PLUMBING AND ELECTRIC) INSTALLED IN THE BUILDING WITHOUT A PERMIT FIRE SEPARATION WALL REMOVED BETWEEN 4827 AND 4831 (UNABLE TO VERIFY LOAD BEARING) OFFICE SPACE COVERED IN TO BAR/SOCIAL CLUB/MULTIPLE ROOMS CONSTRUCTED 14A-4-401 | 4827 W IRVING PARK RD | COMPLAINT | FAILED | View |
RESTORE EXIT AND EM | RESTORE NON WORKING EM LIGHTS AND EXITS SIGNS THROUGHOUT THE BAR AREAS DANGEROUS AND HAZARDOUS CONDITION | 4827 W IRVING PARK RD | COMPLAINT | FAILED | View |
OBTAIN ELECTRICAL PERMIT AND CONTRACTOR TO CORRECT VIOLATIONS AND FOR INTERIOR ALTERATIONS WITHOUT PLANS AND PERMITS IN 4827 & 4831 UNITS 14A-4-404.6 | 4827 W IRVING PARK RD | COMPLAINT | FAILED | View | |
SOIL/WASTE,VENT PIPE MATRL | REMOVE ALL UNAPPROVED FLEXIBLE WATER SUPPLY LINES AT LAVATORY AND TOILET THROUGHOUT PREMISE | 4827 W IRVING PARK RD | COMPLAINT | FAILED | View |
PROVIDE TRAP FOR FIXTURE | PROVIDE PROPER TRAP FOR THREE COMPARTMENTS BAR SINK ON WESTSIDE OF PREMISES | 4827 W IRVING PARK RD | COMPLAINT | FAILED | View |
ARRANGE FOR REINSPECTION REGAR | REMOVE ALL CEILING TILES TO PROVIDE ACCESS TO INSPECT FULL CEILING 14A-1-104.7 | 4827 W IRVING PARK RD | COMPLAINT | FAILED | View |
SOIL/WASTE,VENT PIPE MATRL | REMOVE ALL PVC WASTE AND VENT PIPING THROUGHOUT THE ENTIRE PREMISES | 4827 W IRVING PARK RD | COMPLAINT | FAILED | View |