PIN: 20244260050000
Property Address: 2300 E 70TH PL
City - Zip: CHICAGO - 60649
2023 Property Class: EX
2023 Township: 70 - Hyde Park
2023 Neighborhood: 70083
2023 Tax District: 70131
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 59 Violations
Violation Inspector Comments Address Category Status View
REPAIR CORNICE SOUTH ELEVATION - CORNICE OPEN MORTAR JOINT. 2300 E 70TH PL PERIODIC FAILED View
REPAIR FENCE NORTH ELEVATION - 80'X7' HIGH CHAIN LINK FENCE PERMIT REQUIRED . 2300 E 70TH PL PERIODIC FAILED View
PARAPET PARAPET WALL- LOOSE, SPALLING, AND MISSING BRICKS AT SOUTH AND WEST ELEVATIONS IN VARIOUS LOCATIONS 2300 E 70TH PL COMPLAINT FAILED View
STOP/REMOVE NUISANCE REAR PORCHES - STORING BBQ GRILLS. 2300 E 70TH PL PERIODIC FAILED View
POST OWNER/MANAGERS NAME/# BUILDING OWNER ID NOT POSTED 2300 E 70TH PL PERIODIC FAILED View
REPAIR COPING SOUTH ELEVATION - COPING OPEN MORTAR JOINTSWEST ELEVATION - COPING WASHED OUT MORTAR 2300 E 70TH PL PERIODIC FAILED View
REPAIR WINDOW SILLS SOUTH ELEVATION - WINDOW SILLS OPEN MORTAR JOINTS 2300 E 70TH PL PERIODIC FAILED View
PARAPET WEST ELEVATIONS- 3 PARAPET WALLS WASHED OUT MORTAR AND SPALLING BRICKS. 2300 E 70TH PL PERIODIC FAILED View
REPAIR LINTELS WEST ELEVATION- 7015 2ND FLOOR (2) 8' LINTELS SAGGING AND RUSTED. PLANS AND PERMIT REQUIRED FOR REPLACING LINTELS 2300 E 70TH PL PERIODIC FAILED View
PERMIT REQUIRED - CONTRACTOR NORTH ELEVATION - 2ND AND 3RD FLOOR 9 WINDOWS BOARD UP .PERMIT REQUIRED FOR WINDOWS BOARD UP.FRONT 7315 AND 7317 (6) 3" LINTELS RUSTED AND SAGGING PERMIT REQUIRED FOR REPLACING LINTELS 2300 E 70TH PL PERIODIC FAILED View
CARB MONOX DETECT IN RESID BASEMENT LAUNDRY ROOM NO CARBON MONOXIDE. 2300 E 70TH PL PERIODIC FAILED View
ARRANGE PREMISE INSPECTION INTERIOR OF APTS. - NO ENTRY, UNVERIFIED DETECTORS AND CONDITIONS. UNABLE TO GAIN ENTRY TO INTERIOR STAIRWAYS AND SOME BASEMENTS. UNABLE TO VERIFY COMPLAINT AT 2304 APT 2 FOR RATS AND KITCHEN FLOOR DAMAGED. 2300 E 70TH PL PERIODIC FAILED View
REPAIR PORCH SYSTEM NORTH ELEVATION AT EAST PORCH / WOOD TREADS AND DECKING - CRACKING AND LOOSE. STEEL HARDWARE - RUSTED. 2300 E 70TH PL PERIODIC FAILED View
NO POSTED ADDRESS 2304 / ADDRESS - MISSING. 2300 E 70TH PL PERIODIC FAILED View
REPAIR PORCH SYSTEM 1.-ALL EXTERIOR PORCH AND STAIR SYSTEMS GUARD AND HAND RAILS WITH THE PICKET ANCHORED ON THE OUT SIDE OF BOTTOM AND TOP RAILS.2.-NO PERMIT REQUIRED. 2300 E 70TH PL PERIODIC FAILED View
FILE BLDG REGISTRATION REGISTER BUILDING 1990 THRU 2009 2300 E 70TH PL PERIODIC FAILED View
FILE BLDG REGISTRATION REGISTER BUILDING 1990 THRU 2009 2300 E 70TH PL PERIODIC FAILED View
REPAIR INTERIOR STAIR SYSTEM GRADE TO BASEMENT STEPS TO LAUNDRY ROOM WITH OUT A GUARD AND HAND RAILINGS. 2300 E 70TH PL PERIODIC FAILED View
REPAIR PORCH SYSTEM 1.-ALL EXTERIOR PORCH AND STAIR SYSTEMS GUARD AND HAND RAILS WITH THE PICKET ANCHORED ON THE OUT SIDE OF BOTTOM AND TOP RAILS.2.-NO PERMIT REQUIRED. 2300 E 70TH PL PERIODIC FAILED View
REPAIR INTERIOR STAIR SYSTEM GRADE TO BASEMENT STEPS TO LAUNDRY ROOM WITH OUT A GUARD AND HAND RAILINGS. 2300 E 70TH PL PERIODIC FAILED View
RAT PROOF EXTERIOR DOOR REAR EXTERIOR DOORS (THREE), OPEN GAP (BOTTOM). 2300 E 70TH PL COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# NO SIGN POSTED 2300 E 70TH PL COMPLAINT FAILED View
REPAIR EXTERIOR STAIR FRONT ELEVATION NO HANDRAIL AT 2300 STAIR AND BASEMENT UNIT 2300 E 70TH PL COMPLAINT FAILED View
PROVIDE GUARD RAIL 42 IN HIGH FRONT ELEVATION NO GUARDRAIL # 2300 STAIR TO BASEMENT 2300 E 70TH PL COMPLAINT FAILED View
REPAIR/REPLACE SMOKE DETECTORS UNIT 2310 1ST FLOOR SMOKE DETECTOR NOT WORKING 2300 E 70TH PL COMPLAINT FAILED View
UNSANITARY CONDITIONS-ANIMALS REAR YARD PIGEONS NESTING 2300 E 70TH PL COMPLAINT FAILED View
SERVICE WALK, PASSAGE, AREAWAY REAR YARD HOLE IN CONCRETE AT 2302-04 BASE UNDER CONCRETE WASHED AWAY 2300 E 70TH PL COMPLAINT FAILED View
DEBRIS, EXCESSIVE ACCUMULATION OF JUNK AND DEBRIS AT 2302-04 REAR PORCH 2300 E 70TH PL COMPLAINT FAILED View
REPLCE WINDOW PANES, PLEXGLAS REAR ELEVATION AT 1ST FLOOR BROKEN PANE 2300 E 70TH PL COMPLAINT FAILED View
FOUNDATION, ADEQUATELY SUPPORT 2302-04 FOUNDATION TWISTED OUT OF PLACE POURED ON SLAB 2300 E 70TH PL COMPLAINT FAILED View
REPAIR PORCH SYSTEM 7015-17 REAR PORCH JOIST OVER SIZED FOR SPAN SPLICED OVER BEAM AND SCABBED MISSING STEEL ANGLE BRACKETS THROUGHOUT PORCH COLUMNS BUTT SPLICED RAILS NOT 42" RAILS ROTTED MISSING BALUSTRADES AT GRADE TO 1 AND BETWEEN 2AND 3 NO BOLTED CONNECTIONS, TREADS CRACKED AND ROTTED AT 3RD FLOOR 7025 PORCH JOISTS UNDERSIZED FOR SPAN, NO JOIST HANGERS COLUMNS OVER NOTCHED AND BUTT SPLICED RAILS BELOW 42" NO BOLTED STRINGER CONNECTIONS DECKING ROTTED AT 3RD FLOOR 2302-04 JOIST UNDERSIZED FOR SPAN NO STEEL ANGLE BRACKETS AT BEAM TO COLUMN CONNECTIONS, FIRE CUT BEAM TI COLUMN CONNECTIONS: COLUMNS BUTT SPLICED RAILS NOT 42" ROTTING AND CRACKED AT 2ND-3RD FLOORS MISSING BALUSTRADES AT GRADE TO 1 STAIR NO BOLTED STRINGER CONNECTIONS 2308-10 PORCH JOISTS UNDERSIZED FOR SPAN NO JOIST HANGERS NO ANGLE BRACKETS AT BEAM TO COLUMN CONNECTIONS GAPS AT FIRE CUTS AT BEAM TO COLUMN CONNECTIONS COLUMNS BUTT SPLICED RAILS NOT 42" HIGH LOOSE THROUGHOUT NO BOLTED STRINGER CONNECTIONS 2300 E 70TH PL COMPLAINT FAILED View
PLANS & PERMITS REQ - CONTRCTR OBTAIN PLANS AND PERMITS FOR REPAIR TO ALL REAR PORCHES PLANS MAY BE AVAILABLE (FREE OF CHARGE) AT THE CITY OF CHICAGO WEB SITE 2300 E 70TH PL COMPLAINT FAILED View
WORK NOT ALLOWED REAR CHAIN LINK FENCE OVER 5 FEET. REMOVE, REDUCE HEIGHT, OR OBTAIN PERMIT TO KEEP AS IS 2300 E 70TH PL COMPLAINT FAILED View
REPAIR EXTERIOR WALL EXTERIOR MASONRY WALL- SPALLING BRICK AND WASHED OUT MORTAR IN VARIOUS LOCATIONS OF THE COURTYARD 2300 E 70TH PL COMPLAINT FAILED View
REPAIR AREAWAY WALL WEST PASSAGEWAY CONNECTING PUBLIC SIDEWALK TO COURTYARD- PLYWOOD CEILING. PROPER FIRE SEPARATION IS REQUIRED 2300 E 70TH PL COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION NO ENTRY TO INTERIOR. UNVERIFIED OCCUPANCY, DETECTORS, OR LIVING CONDITIONS 2300 E 70TH PL COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# MISSING OWNER'S MANAGEMENT SIGN 2300 E 70TH PL COMPLAINT FAILED View
GROUND EQUIPMENT PROVIDE A WATER MAIN GROUND CONDUCTOR AND CONDUIT RUN TO WITHIN FIVE FEET OF WATER METER OR VALVE 2300 E 70TH PL COMPLAINT PASSED View
LIVE FRONT SWITCHBOARD REPLACE LIVE FRONT DISCONNECT WITH DEAD FRONT TYPE IN 2302 BASEMENT AREA 2300 E 70TH PL COMPLAINT PASSED View
DEFECTIVE FIXTURES IN LAUNDRY ROOM LIGHT FIXTURE HAS UN APPROVED CORD TO LIGHT 2300 E 70TH PL COMPLAINT PASSED View
SEE INSPECTOR COMMENTS PROVIDE GFCI PROTECTION FOR LAUNDRY ROOM AREAS 18-27-210.8 2300 E 70TH PL COMPLAINT PASSED View
PLASTIC EMERGENCY LIGHTS ARE NOT APPROVED FOR USE IN STAIRWAY AREAS 18-27-700.66.3 2300 E 70TH PL COMPLAINT PASSED View
SECURE RACEWAY PROPERLY SUPPORT FEEDER CONDUIT RUNS AT REAR EXTERIOR PORCH AREAS 2300 E 70TH PL COMPLAINT PASSED View
REPLACE D&H PORCH DANGEROUS AND HAZARDOUS PIER-TYPE STAIR SYSTEMS AT 7015-17 S. CRANDON AND 2310 E. 70 PL. PORCHES. THESE STAIR SECTIONS WILL SWAY UNDER LOAD WITH THE POTENTIAL FOR COLLAPSE. DRY ROTTED TOP RAILS AND SPLIT TREADS AT 7015-17 S. CRANDON STAIR SECTION. ALL LEVELS AND ELEVATIONS PICKETS AT HAND AND GUARDRAILS ARE ATTACHED AT THE OUTSIDE OF THE RAILS. PLANS AND PERMIT ARE REQUIRED TO REPLACE STAIR SECTIONS. 2300 E 70TH PL COMPLAINT PASSED View
PRV BALLCOCK,VB,OR AIR GAP SILCOCK SOUTH ELEVATION AND NORTH ELEVATION IN COURTYARD. 2300 E 70TH PL COMPLAINT PASSED View
PROPER MATRL WATER SUPPLY PIPE REMOVE FLEXIBLE SUPPLIES TO KITCHEN FAUCET, LAVATORY AND TOILET 2300 GARDEN UNIT WEST. 2300 E 70TH PL COMPLAINT PASSED View
REPLACE DEFECTIVE TOILET SEAT TOILET SEAT WORN RESTROOM 2300 GARDEN UNIT WEST. 2300 E 70TH PL COMPLAINT PASSED View
INSTALL ILLUMINATION INSTALL ILLUMINATION TO ALL BASEMENT AND GROUND LEVEL EXTERIOR ENTRY DOORS. ALL SUPPORT BOXES AND LIGHT FIXTURES MUST BE WEATHERPROOF. 2300 E 70TH PL COMPLAINT PASSED View
SYSTEM III INSTALL EMERGENCY LIGHTING SYSTEM III AT ALL ENTRY DOORS AT GROUND LEVEL. 2300 E 70TH PL COMPLAINT PASSED View
(13-12-360) PROVIDE PERMIT TO CORRECT VIOLATIONS. 2300 E 70TH PL COMPLAINT PASSED View
OBTAIN ELECTRICAL PERMIT TO CORRECT ELECTRICAL VIOLATIONS 13-12-360 2300 E 70TH PL COMPLAINT PASSED View
SECURE RACEWAY PROPERLY SUPPORT CONDUIT BOX NOT SUPPORTED IN LAUNDRY ROOM AND BOILER ROOM AREAS 2300 E 70TH PL COMPLAINT PASSED View
SYSTEM III PROVIDE SYSTEM III EMERGENCY LIGHTS IN ALL STAIRWAYS CORRIDORS COMMON AREAS BASEMENT AND REAR PORCH AREAS 2300 E 70TH PL COMPLAINT PASSED View
WORKING SPACE PROVIDE PROPER CLEARANCES FOR JUNCTION BOX AND SERVICE DISCONNECT IN MAIN ELECTRICAL ROOM IN BASEMENT. 2300 E 70TH PL COMPLAINT PASSED View
HEATING PLANT SEPARATION BOILER ROOM AND ADJECENT ROOMS WITH DAMAGED PLASTER CEILING AREAS, SEE BUCKLED AND SAGGING SECTIONS, EXPOSED WOOD LATH, CRACKED AND OPEN AREAS, UNFINISHED DRYWALL REPAIR AREA. 2300 E 70TH PL PERIODIC FAILED View
INT WALL/CEILING CHIP PLASTER 2300 E. REAR BASEMENT COMMON AREA LOOSE AND MISSING PLASTER AT SOUTH WEST WALL AND CEILING NEAR STEAM PIPE. 2300 E 70TH PL COMPLAINT PASSED View
REPAIR EXTERIOR DOOR FRONT MAIN ENTRY AND VESTIBULE DOORS - DEFECTIVE LOCKSETS. 2300 E 70TH PL COMPLAINT FAILED View
REPAIR CORNICE WEST AND EAST STONE CORNICE - WASHED OUT MORTAR. 2300 E 70TH PL COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION BUILDING INTERIOR - NO RESPONSE, UNVERIFIED DETECTORS. UNABLE TO INSPECT PREVIOUSLY WRITTEN VIOLATIONS. 2300 E 70TH PL PERIODIC FAILED View