The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
LICENSED BONDED PLMBG CONTRCTR | 1718 N CALIFORNIA AVE | COMPLAINT | FAILED | View | |
PRV RELIEF VALVE HOTWATER HTR | RELIEF TUBE TO MEET CODE | 1718 N CALIFORNIA AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | SR07-0216318-NO OWNERS I.D POSTED | 1718 N CALIFORNIA AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | MISSING AND LOOSE SIDING SOUTH ELEVATION HOLES CUT INTO WALLS SOUTH AND WEST FOR PLUMBING REPAIRS | 1718 N CALIFORNIA AVE | COMPLAINT | FAILED | View |
RATS-ELEVATE MATERIAL 18" | REAR YARD WOOD PILES | 1718 N CALIFORNIA AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | REAR STAIRS FOR 2ND FLOOR MISSING HANGERS, PLYWOOD DECK, LOW GUARD AND HAND RAILS, MUCH ROTTED WOOD ALL STEPS ARE ROTTED. ONE 4X4 SUPPORT COLUMN HAS BEEN REMOVED. PERMIT TO REPAIR | 1718 N CALIFORNIA AVE | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | 1ST FLOOR REAR DOOR MISSING DEAD BOLT | 1718 N CALIFORNIA AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | INTERIOR STAIRS MISSING PICKETS | 1718 N CALIFORNIA AVE | COMPLAINT | FAILED | View |
ARMORED CABLE | ABOVE DROP CEILING 1ST FLOOR PERMIT NEEDED | 1718 N CALIFORNIA AVE | COMPLAINT | FAILED | View |
PROPER SIZE OCP | USE PROPER SIZE BREAKERS FOR ALL WIRING ENTIRE BUILDING | 1718 N CALIFORNIA AVE | COMPLAINT | FAILED | View |
DEFECTIVE OUTLETS | RESTORE ALL NON WORKING RECEPTACLES AND SWITCHES WHERE DAMAGED BY FIRE AND REPLACE WORN RECEPTACLES ENTIRE HOUSE PERMIT NEEDED | 1718 N CALIFORNIA AVE | COMPLAINT | FAILED | View |
ADD RECEPTACLES | TO REMOVE CORD WIRING IN BEDROOMS AND WHERE NEEDED | 1718 N CALIFORNIA AVE | COMPLAINT | FAILED | View |
VERIFY PROPER CONNECTING OF ALL CIRCUITS AND REMOVE OBSTRUCTIONS TO VERIFY PROPER WIRING METHODS 18-27-110.3 AND 18-27-210.4 AND 13-12-170 PERMIT REQUIRED | 1718 N CALIFORNIA AVE | COMPLAINT | FAILED | View | |
ARRANGE FOR REINSPECTION REGAR | 1718 N CALIFORNIA AVE | COMPLAINT | FAILED | View | |
DEFECTIVE LIGHTING SERVICE | SERVICE DISCONNECT IN BATH ROOM,IMPROPER GROUNDING | 1718 N CALIFORNIA AVE | COMPLAINT | FAILED | View |
SUPPLY HOT WTR MIN TEMP 120DEG | 1718 N CALIFORNIA AVE | COMPLAINT | FAILED | View |