The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
1HR FLR OVER BSMT, 1 OR 2 DU | BREACHES AT BASEMENT CEILING. | 3636 W 111TH ST | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | FRACTURES AT NORTH - 1ST FLOOR ABOVE WINDOWS & DOOR, SOUTH & EAST ELEVATIONS. | 3636 W 111TH ST | PERIODIC | FAILED | View |
REPAIR EXTERIOR STAIR | NO HANDRAIL AT REAR BASEMENT STAIRS. | 3636 W 111TH ST | PERIODIC | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | BASEMENT STAIRS - LOOSE STRINGERS. | 3636 W 111TH ST | PERIODIC | FAILED | View |
1-HR HEATING PLANT ENCLOSURE | ENCLOSE BOILER.FURNACE WITH 1HOUR FIRE RATING. | 3636 W 111TH ST | PERIODIC | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | PERMITS FOR FIRE SEPARATIONS. | 3636 W 111TH ST | PERIODIC | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | PERMIT FOR FIRE SEPARATION FOR BASEMENT CEILING & FURNACE ENCLOSURE | 3636 W 111TH ST | PERIODIC | FAILED | View |
POST APPROVED OCCUPANCY CARD | OBTAIN & POST NEW OCCUPANCY CARDS-FIXED TABLES REMOVED IN BAR & OUSTIDE PATIO HAS BEEN REDUCED | 3636 W 111TH ST | PERIODIC | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | PROVIDE DOCUMENTATION ENCLOSING PORTION OF BEER GARDEN WAS DONE WITH PLANS/PERMITS | 3636 W 111TH ST | PERIODIC | FAILED | View |
NO KEY TO USE EXIT DOOR | REAR EXIT GATE/ DOOR SWINGS AGAINST DIRECTION OF TRAVEL. | 3636 W 111TH ST | PERIODIC | FAILED | View |
1HR FLR OVER BSMT, 1 OR 2 DU | PROVIDE 1 HR FIRE RATED CEILING AT BASEMENT. | 3636 W 111TH ST | PERIODIC | PASSED | View |
CARB MONOX DETECT IN RESID | PROVIDE CO 2 DETECTOR A BASEMENT & 1ST FLR. | 3636 W 111TH ST | PERIODIC | FAILED | View |
POST APPROVED OCCUPANCY CARD | POST OCCUPANCY CARD FOR 148PPL FOR 1ST FLR LOUNGE FROM APPROVED APPLICATION #36356 IN 2011. | 3636 W 111TH ST | PERIODIC | PASSED | View |
PROVIDE OPEN FRONT TOILET SEAT | BATHROOM BASEMENT TOILET HAS NO OPEN FRONT SEAT | 3636 W 111TH ST | COMPLAINT | FAILED | View |
VENT SYSTEM TO PRVNT BACK PRES | LAUNDRY SINK IS NOT CONNECTED TO VENTING SYSTEM IN BASEMENT | 3636 W 111TH ST | COMPLAINT | FAILED | View |
STOP LEAKING WATER | LEAK AT CEILING IN BASEMENT | 3636 W 111TH ST | COMPLAINT | FAILED | View |
1HR FLR OVER BSMT, 1 OR 2 DU | REPLACE MISSING SECTIONS OF DRYWALL AT BASEMENT CEILING. MUST BE 5/8 INCH TYPE X DRYWALL AND FIRE TAPED. | 3636 W 111TH ST | PERIODIC | FAILED | View |
CARB MONOX DETECT IN RESID | INSTALL CARBON MONOXIDE DETECTOR IN BASEMENT. | 3636 W 111TH ST | PERIODIC | FAILED | View |
THAT ON OR ABOUT | APRIL 13TH INSPECTOR FOUND VIOLATIONS THAT REQUIRE IMMEDIATE ATTENTION. IF NOT CORRECTED IN 30 DAYS WE MAY PURSUE COURT ACTION. | 3636 W 111TH ST | PERIODIC | FAILED | View |
STOP/REMOVE NUISANCE | REMOVE ACCUMULATION OF DEBRIS FROM BASEMENT. | 3636 W 111TH ST | PERIODIC | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | OBTAIN PERMIT FOR: (1) INSTALLATION OF NEW 4 IN X 6 IN WOOD BEAMS AND STEEL TUBE COLUMNS AT BASEMENT. (2) ALTERATIONS IN BEER GARDEN THAT INCLUDED ADDITION OF A BAR AND REDUCTION IN AMOUNT OF FIXED SEATING. | 3636 W 111TH ST | PERIODIC | FAILED | View |
POST APPROVED OCCUPANCY CARD | REPALCE MISSING OCCUPANCY PLACARD AT FIRST FLOOR LOUNGE AND OBTAIN REVISED OCCUPANCY PLACARD FOR BEER GARDEN TO REFLECT ALTERATIONS. | 3636 W 111TH ST | PERIODIC | FAILED | View |
NO ENTRY | 3636 W 111TH ST | PERIODIC | FAILED | View | |
REPAIR EXTERIOR DOOR HARDWARE | REMOVE KEYED CYLINDER LOCKS ON INSIDE OF 2 REAR EXIT GATES AND INSTALL PANIC DEVICES AND EXIT SIGNS. | 3636 W 111TH ST | PERIODIC | FAILED | View |
ILLUMINATE PUBLIC STAIR/HALL | E.M. LIGHTS NOT WORKING AT TIME OF INSPECTION | 3636 W 111TH ST | PERIODIC | FAILED | View |
HEATING PLANT/BOILER ROOM DOOR | PROVIDE CLASS "B" DOOR FOR BOILER/FURNACE ROOM WITH FRAME & CLOSER. | 3636 W 111TH ST | PERIODIC | FAILED | View |
INDIRECT CONN.FOR WATER SUPPLY | NO CHECK VALVE ON BOILER SYSTEM LOCATED IN BASEMENT DANGEROUS AND HAZARDOUS | 3636 W 111TH ST | COMPLAINT | FAILED | View |
INSTALL ILLUMINATION | INSTALL SYSTEM III EMERGENCY LIGHTING THROUGHOUT BASEMENT FOR CLEAR PATH TO EGRESS ALONG WITH ILLUMINATING ELECTRICAL SERVICE EQUIPMENT IN CASE OF POWER OUTAGE DANGEROUS AND HAZARDOUS | 3636 W 111TH ST | COMPLAINT | FAILED | View |
EXPOSED WIRING | CONCEAL ALL OPEN WIRING THROUGHOUT SPECIFICALLY IN THE FRONT BASEMENT AREA HANDY BOX DANGEROUS AND HAZARDOUS | 3636 W 111TH ST | COMPLAINT | FAILED | View |
SOIL/WASTE,VENT PIPE MATRL | PVC LOCATED THROUGHOUT BASEMENT | 3636 W 111TH ST | COMPLAINT | FAILED | View |
CORRODED CONDUIT & EQUIP | REPLACE ALL CORRODED AND DETERIORATED CONDUITS THROUGHOUT SPECIFICALLY IN THE BASEMENT FOR SUB PANEL SEVERELY RUSTED 2" CONDUIT FROM MDP REPLACE RUSTED BX THROUGHOUT BASEMENT DANGEROUS AND HAZARDOUS | 3636 W 111TH ST | COMPLAINT | FAILED | View |
LICENSED BONDED PLMBG CONTRCTR | EMPLOY LICENSED AND BONDED PLUMBING CONTRACTOR FOR PLUMBING WORK TO BE PERFORMED TO ADDRESS PLUMBING VIOLATIONS | 3636 W 111TH ST | COMPLAINT | FAILED | View |
APPLIANCE INSIGHT DISCONNECT | INSTALL MAINTENANCE DISCONNECT SWITCH FOR WALK-IN COOLER EVAPORATOR IN BASEMENT | 3636 W 111TH ST | COMPLAINT | FAILED | View |
REPLACE DEFECTIVE WASTE PIPING | 3 COMPARTMENT SINK WASTE IS NOT INTO OPEN SITE OR GREASE BOX 164027 | 3636 W 111TH ST | COMPLAINT | FAILED | View |
PRV BALLCOCK,VB,OR AIR GAP | NO VACUUM BREAKER ON HOSE BIBB LOCATED IN BASEMENT DANGEROUS AND HAZARDOUS | 3636 W 111TH ST | COMPLAINT | FAILED | View |
EXPOSED WIRING FIXTURES | CONCEAL OPEN WIRING AT JANITORS MOP CLOSET CEILING LIGHT DANGEROUS AND HAZARDOUS | 3636 W 111TH ST | COMPLAINT | FAILED | View |
RMV DFT PIPE,FITTING,FIXTURE | UNAPPROVED FERNCO FITTINGS THROUGHOUT BASEMENT | 3636 W 111TH ST | COMPLAINT | FAILED | View |
INSTALL COVERS | INSTALL COVERS ON ALL DEVICES WHICH ARE MISSING THROUGHOUT ALONG WITH ALL OPEN JUNCTION BOXES DANGEROUS AND HAZARDOUS | 3636 W 111TH ST | COMPLAINT | FAILED | View |
MIXED OCCUPANCY SEPARATION | MISSING FIRE SEPARATION AT 1ST FLOOR UNTILITY CLOSET CEILING A 1 HOUR FIRE SEPARATION IS REQUIRED 14B-5-508 DANGEROUS AND HAZARDOUS | 3636 W 111TH ST | COMPLAINT | FAILED | View |
1HR FLR OVER BSMT, 1 OR 2 DU | MISSING SECTIONS OF DRYWALL AT BASEMENT IN VARIOUS LOCATIONS A 1 HOUR FIRE SEPARATION IS REQUIRED 14B-6-605.4 DANGEROUS AND HAZARDOUS | 3636 W 111TH ST | COMPLAINT | FAILED | View |
DWELLING CLEAN AND SANITARY | THERE IS A BLACK ORGANIC MOLD LIKE SUBSTANCE IN BASEMENT MECHANICAL ROOM CEILING AND IN VARIOUS AREAS NEAR REAR BASEMENT 14X-1-103 UNSANITARY | 3636 W 111TH ST | COMPLAINT | FAILED | View |
NO GASOLINE(LPG) STORAGE | REMOVE PROPANE TANK FROM BASEMENT 15-26-540 DANGEROUS AND HAZARDOUS | 3636 W 111TH ST | COMPLAINT | FAILED | View |
FIRE EXTNGSHR REQ, NONRESDNTL | FIRE EXTINGUISHERS NOT PROPERLY HUNG 14X-5-504.5 DANGEROUS AND HAZARDOUS | 3636 W 111TH ST | COMPLAINT | FAILED | View |
NO KEY TO USE EXIT DOOR | (2) REAR WOODEN GATES DOUBLE KEY LOCK (LOCKED) REQUIRES KEY FROM SIDE OF EGRESS 14X-5-505.1.2.2 DANGEROUS AND HAZARDOUS | 3636 W 111TH ST | COMPLAINT | FAILED | View |
SUBMIT 2 COPY STRUCTURAL RPT | BASEMENT AREA THERE ARE TEMP LALLY COLUMNS SUPPORTING A 4X6 BEAM PERPINDICULAR TO THE JOISTS AT THE WEST ELEVATION APPEARS THE ORIGINAL JOISTS THAT ARE SITTING IN THE POCKET ARE ROTTED AND DETERIORATING PROVIDE A STRUCTURAL ENGINEERS REPORT TO DETERMINE STRUCTURAL STABILITY AND REPAIRS TO BE MADE TEMP LALLY COLUMNS ARE NOT PERMITTED FOR PERMANENT USE 14X-1-104.1 | 3636 W 111TH ST | COMPLAINT | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | A PERMIT IS REQUIRED FOR REPAIRS MADE ACCORDING TO THE STRUCTURAL ENGINEERS REPORT 14A-4-401.1 | 3636 W 111TH ST | COMPLAINT | FAILED | View |
OBTN PERMIT FOR PLUMBING WORK | OBTAIN PLUMBING PERMIT FOR PLUMBING WORK TO BE PERFORMED | 3636 W 111TH ST | COMPLAINT | FAILED | View |
INDIRECT CONN.FOR WATER SUPPLY | NO CHECK VALVE AT CO-2 SODA MACHINE LOCATED IN BASEMENT DANGEROUS AND HAZARDOUS | 3636 W 111TH ST | COMPLAINT | FAILED | View |
INDIRECT CONN.FOR WATER SUPPLY | NO CHECK VALVE AT ICE MACHINE LOCATED IN BASEMENT DANGEROUS AND HAZARDOUS | 3636 W 111TH ST | COMPLAINT | FAILED | View |
SOIL/WASTE,VENT PIPE MATRL | PVC LOCATED ON HAND SINK BEHIND BAR 1ST FLOOR AND BAR GARDEN REAR | 3636 W 111TH ST | COMPLAINT | FAILED | View |
PRV FLOOR DRAIN WITH METAL STR | BATHROOM BASEMENT HAS NO FLOOR DRAIN | 3636 W 111TH ST | COMPLAINT | FAILED | View |
SUBMIT REVISED PLANS FOR PERMT | PATIO BAR INSTALLED WITHOUT PLANS AND PERMIT | 3636 W 111TH ST | COMPLAINT | FAILED | View |
ADD RECEPTACLES | ADD ADDITIONAL RECEPTACLES THROUGHOUT IN ORDER TO ELIMINATE OVER USE OF CORDS THROUGHOUT SPECIFICALLY FOR ALL AMUSEMENT EQUIPMENT AND ON THE EXTERIOR FOR FESTOON TYPE LIGHTING IN BEER GARDEN DANGEROUS AND HAZARDOUS | 3636 W 111TH ST | COMPLAINT | FAILED | View |
CONTINUITY OF RACEWAYS | PROVIDE PROPER CONTINUITY OF ALL RACEWAYS THROUGHOUT BY TIGHTENING ALL LOOSE FITTING SPECIFICALLY THROUGHOUT BASEMENT DANGEROUS AND HAZARDOUS | 3636 W 111TH ST | COMPLAINT | FAILED | View |
RESTORE EXIT AND EM | RESTORE ALL EXIT SIGNS AND EM LIGHTING THROUGHOUT 1ST FLOOR BAR AREA ALONG WITH BATHROOM WHICH WERE ALL INOPERABLE DANGEROUS HAZARDOUS | 3636 W 111TH ST | COMPLAINT | FAILED | View |
SECURE RACEWAY | PROPERLY SECURE ALL CONDUITS AND BOXES THROUGHOUT THE BASEMENT | 3636 W 111TH ST | COMPLAINT | FAILED | View |
LISTED FOR USE TEMP & LOCATION | INSTALL PROPER BRANCH CIRCUIT BREAKERS WHICH ARE LISTED FOR USE BY PANEL MANUFACTURER INSTALL PROPER JUNCTION BOXES WHICH ARE LISTED FOR USE IN DAMP/WET LOCATIONS INSIDE WALK-IN COOLER IN THE BASEMENT DANGEROUS AND HAZARDOUS | 3636 W 111TH ST | COMPLAINT | FAILED | View |
CLOSE BOX OPENINGS | INSTALL KO FILLERS IN ALL OPEN UNUSED OPENINGS IN JUNCTION BOXES THROUGHOUT THE BASEMENT DANGEROUS AND HAZARDOUS | 3636 W 111TH ST | COMPLAINT | FAILED | View |
UNAPPROVED CORDS | REMOVE ALL EXTENSION CORDS THROUGHOUT INTERIOR AND EXTERIOR (BEER GARDEN) BEING USED TO PERMANENT FIXED ELECTRICAL EQUIPMENT DANGEROUS AND HAZARDOUS | 3636 W 111TH ST | COMPLAINT | FAILED | View |
INSTALL GFCI'S | PROVIDE GFCI PROTECTION TO ALL REQUIRED RECEPTACLES THROUGHOUT SPECIFICALLY IN EXTERIOR BEER GARDEN AREA DANGEROUS AND HAZARDOUS | 3636 W 111TH ST | COMPLAINT | FAILED | View |
SEE INSPECTOR COMMENTS | PROVIDE ELECTRICAL PERMIT IN ORDER TO CORRECT ELECTRICAL VIOLATIONS (14A-4-404.6) | 3636 W 111TH ST | COMPLAINT | FAILED | View |
1HR FLR OVER BSMT, 1 OR 2 DU | MISSING SECTIONS OF DRYWALL AT BASEMENT IN VARIOUS LOCATIONS A 1 HOUR FIRE SEPARATION IS REQUIRED 14B-6-605.4 DANGEROUS AND HAZARDOUS | 3636 W 111TH ST | COMPLAINT | FAILED | View |
MIXED OCCUPANCY SEPARATION | MISSING FIRE SEPARATION AT 1ST FLOOR UNTILITY CLOSET CEILING A 1 HOUR FIRE SEPARATION IS REQUIRED 14B-5-508 DANGEROUS AND HAZARDOUS | 3636 W 111TH ST | COMPLAINT | FAILED | View |