Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-24 @ 4:01 PM
PIN: 24143160710000
Property Address: 3636 W 111TH ST
City - Zip: CHICAGO - 60655
2023 Property Class: 212
2023 Township: 72 - Lake
2023 Neighborhood: 72422
2023 Tax District: 72112
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 63 Violations
Violation Inspector Comments Address Category Status View
1HR FLR OVER BSMT, 1 OR 2 DU BREACHES AT BASEMENT CEILING. 3636 W 111TH ST PERIODIC FAILED View
REPAIR EXTERIOR WALL FRACTURES AT NORTH - 1ST FLOOR ABOVE WINDOWS & DOOR, SOUTH & EAST ELEVATIONS. 3636 W 111TH ST PERIODIC FAILED View
REPAIR EXTERIOR STAIR NO HANDRAIL AT REAR BASEMENT STAIRS. 3636 W 111TH ST PERIODIC FAILED View
REPAIR INTERIOR STAIR SYSTEM BASEMENT STAIRS - LOOSE STRINGERS. 3636 W 111TH ST PERIODIC FAILED View
1-HR HEATING PLANT ENCLOSURE ENCLOSE BOILER.FURNACE WITH 1HOUR FIRE RATING. 3636 W 111TH ST PERIODIC FAILED View
PLANS & PERMITS REQ - CONTRCTR PERMITS FOR FIRE SEPARATIONS. 3636 W 111TH ST PERIODIC FAILED View
PLANS & PERMITS REQ - CONTRCTR PERMIT FOR FIRE SEPARATION FOR BASEMENT CEILING & FURNACE ENCLOSURE 3636 W 111TH ST PERIODIC FAILED View
POST APPROVED OCCUPANCY CARD OBTAIN & POST NEW OCCUPANCY CARDS-FIXED TABLES REMOVED IN BAR & OUSTIDE PATIO HAS BEEN REDUCED 3636 W 111TH ST PERIODIC FAILED View
PLANS & PERMITS REQ - CONTRCTR PROVIDE DOCUMENTATION ENCLOSING PORTION OF BEER GARDEN WAS DONE WITH PLANS/PERMITS 3636 W 111TH ST PERIODIC FAILED View
NO KEY TO USE EXIT DOOR REAR EXIT GATE/ DOOR SWINGS AGAINST DIRECTION OF TRAVEL. 3636 W 111TH ST PERIODIC FAILED View
1HR FLR OVER BSMT, 1 OR 2 DU PROVIDE 1 HR FIRE RATED CEILING AT BASEMENT. 3636 W 111TH ST PERIODIC PASSED View
CARB MONOX DETECT IN RESID PROVIDE CO 2 DETECTOR A BASEMENT & 1ST FLR. 3636 W 111TH ST PERIODIC FAILED View
POST APPROVED OCCUPANCY CARD POST OCCUPANCY CARD FOR 148PPL FOR 1ST FLR LOUNGE FROM APPROVED APPLICATION #36356 IN 2011. 3636 W 111TH ST PERIODIC PASSED View
PROVIDE OPEN FRONT TOILET SEAT BATHROOM BASEMENT TOILET HAS NO OPEN FRONT SEAT 3636 W 111TH ST COMPLAINT FAILED View
VENT SYSTEM TO PRVNT BACK PRES LAUNDRY SINK IS NOT CONNECTED TO VENTING SYSTEM IN BASEMENT 3636 W 111TH ST COMPLAINT FAILED View
STOP LEAKING WATER LEAK AT CEILING IN BASEMENT 3636 W 111TH ST COMPLAINT FAILED View
1HR FLR OVER BSMT, 1 OR 2 DU REPLACE MISSING SECTIONS OF DRYWALL AT BASEMENT CEILING. MUST BE 5/8 INCH TYPE X DRYWALL AND FIRE TAPED. 3636 W 111TH ST PERIODIC FAILED View
CARB MONOX DETECT IN RESID INSTALL CARBON MONOXIDE DETECTOR IN BASEMENT. 3636 W 111TH ST PERIODIC FAILED View
THAT ON OR ABOUT APRIL 13TH INSPECTOR FOUND VIOLATIONS THAT REQUIRE IMMEDIATE ATTENTION. IF NOT CORRECTED IN 30 DAYS WE MAY PURSUE COURT ACTION. 3636 W 111TH ST PERIODIC FAILED View
STOP/REMOVE NUISANCE REMOVE ACCUMULATION OF DEBRIS FROM BASEMENT. 3636 W 111TH ST PERIODIC FAILED View
PLANS & PERMITS REQ - CONTRCTR OBTAIN PERMIT FOR: (1) INSTALLATION OF NEW 4 IN X 6 IN WOOD BEAMS AND STEEL TUBE COLUMNS AT BASEMENT. (2) ALTERATIONS IN BEER GARDEN THAT INCLUDED ADDITION OF A BAR AND REDUCTION IN AMOUNT OF FIXED SEATING. 3636 W 111TH ST PERIODIC FAILED View
POST APPROVED OCCUPANCY CARD REPALCE MISSING OCCUPANCY PLACARD AT FIRST FLOOR LOUNGE AND OBTAIN REVISED OCCUPANCY PLACARD FOR BEER GARDEN TO REFLECT ALTERATIONS. 3636 W 111TH ST PERIODIC FAILED View
NO ENTRY 3636 W 111TH ST PERIODIC FAILED View
REPAIR EXTERIOR DOOR HARDWARE REMOVE KEYED CYLINDER LOCKS ON INSIDE OF 2 REAR EXIT GATES AND INSTALL PANIC DEVICES AND EXIT SIGNS. 3636 W 111TH ST PERIODIC FAILED View
ILLUMINATE PUBLIC STAIR/HALL E.M. LIGHTS NOT WORKING AT TIME OF INSPECTION 3636 W 111TH ST PERIODIC FAILED View
HEATING PLANT/BOILER ROOM DOOR PROVIDE CLASS "B" DOOR FOR BOILER/FURNACE ROOM WITH FRAME & CLOSER. 3636 W 111TH ST PERIODIC FAILED View
INDIRECT CONN.FOR WATER SUPPLY NO CHECK VALVE ON BOILER SYSTEM LOCATED IN BASEMENT DANGEROUS AND HAZARDOUS 3636 W 111TH ST COMPLAINT FAILED View
INSTALL ILLUMINATION INSTALL SYSTEM III EMERGENCY LIGHTING THROUGHOUT BASEMENT FOR CLEAR PATH TO EGRESS ALONG WITH ILLUMINATING ELECTRICAL SERVICE EQUIPMENT IN CASE OF POWER OUTAGE DANGEROUS AND HAZARDOUS 3636 W 111TH ST COMPLAINT FAILED View
EXPOSED WIRING CONCEAL ALL OPEN WIRING THROUGHOUT SPECIFICALLY IN THE FRONT BASEMENT AREA HANDY BOX DANGEROUS AND HAZARDOUS 3636 W 111TH ST COMPLAINT FAILED View
SOIL/WASTE,VENT PIPE MATRL PVC LOCATED THROUGHOUT BASEMENT 3636 W 111TH ST COMPLAINT FAILED View
CORRODED CONDUIT & EQUIP REPLACE ALL CORRODED AND DETERIORATED CONDUITS THROUGHOUT SPECIFICALLY IN THE BASEMENT FOR SUB PANEL SEVERELY RUSTED 2" CONDUIT FROM MDP REPLACE RUSTED BX THROUGHOUT BASEMENT DANGEROUS AND HAZARDOUS 3636 W 111TH ST COMPLAINT FAILED View
LICENSED BONDED PLMBG CONTRCTR EMPLOY LICENSED AND BONDED PLUMBING CONTRACTOR FOR PLUMBING WORK TO BE PERFORMED TO ADDRESS PLUMBING VIOLATIONS 3636 W 111TH ST COMPLAINT FAILED View
APPLIANCE INSIGHT DISCONNECT INSTALL MAINTENANCE DISCONNECT SWITCH FOR WALK-IN COOLER EVAPORATOR IN BASEMENT 3636 W 111TH ST COMPLAINT FAILED View
REPLACE DEFECTIVE WASTE PIPING 3 COMPARTMENT SINK WASTE IS NOT INTO OPEN SITE OR GREASE BOX 164027 3636 W 111TH ST COMPLAINT FAILED View
PRV BALLCOCK,VB,OR AIR GAP NO VACUUM BREAKER ON HOSE BIBB LOCATED IN BASEMENT DANGEROUS AND HAZARDOUS 3636 W 111TH ST COMPLAINT FAILED View
EXPOSED WIRING FIXTURES CONCEAL OPEN WIRING AT JANITORS MOP CLOSET CEILING LIGHT DANGEROUS AND HAZARDOUS 3636 W 111TH ST COMPLAINT FAILED View
RMV DFT PIPE,FITTING,FIXTURE UNAPPROVED FERNCO FITTINGS THROUGHOUT BASEMENT 3636 W 111TH ST COMPLAINT FAILED View
INSTALL COVERS INSTALL COVERS ON ALL DEVICES WHICH ARE MISSING THROUGHOUT ALONG WITH ALL OPEN JUNCTION BOXES DANGEROUS AND HAZARDOUS 3636 W 111TH ST COMPLAINT FAILED View
MIXED OCCUPANCY SEPARATION MISSING FIRE SEPARATION AT 1ST FLOOR UNTILITY CLOSET CEILING A 1 HOUR FIRE SEPARATION IS REQUIRED 14B-5-508 DANGEROUS AND HAZARDOUS 3636 W 111TH ST COMPLAINT FAILED View
1HR FLR OVER BSMT, 1 OR 2 DU MISSING SECTIONS OF DRYWALL AT BASEMENT IN VARIOUS LOCATIONS A 1 HOUR FIRE SEPARATION IS REQUIRED 14B-6-605.4 DANGEROUS AND HAZARDOUS 3636 W 111TH ST COMPLAINT FAILED View
DWELLING CLEAN AND SANITARY THERE IS A BLACK ORGANIC MOLD LIKE SUBSTANCE IN BASEMENT MECHANICAL ROOM CEILING AND IN VARIOUS AREAS NEAR REAR BASEMENT 14X-1-103 UNSANITARY 3636 W 111TH ST COMPLAINT FAILED View
NO GASOLINE(LPG) STORAGE REMOVE PROPANE TANK FROM BASEMENT 15-26-540 DANGEROUS AND HAZARDOUS 3636 W 111TH ST COMPLAINT FAILED View
FIRE EXTNGSHR REQ, NONRESDNTL FIRE EXTINGUISHERS NOT PROPERLY HUNG 14X-5-504.5 DANGEROUS AND HAZARDOUS 3636 W 111TH ST COMPLAINT FAILED View
NO KEY TO USE EXIT DOOR (2) REAR WOODEN GATES DOUBLE KEY LOCK (LOCKED) REQUIRES KEY FROM SIDE OF EGRESS 14X-5-505.1.2.2 DANGEROUS AND HAZARDOUS 3636 W 111TH ST COMPLAINT FAILED View
SUBMIT 2 COPY STRUCTURAL RPT BASEMENT AREA THERE ARE TEMP LALLY COLUMNS SUPPORTING A 4X6 BEAM PERPINDICULAR TO THE JOISTS AT THE WEST ELEVATION APPEARS THE ORIGINAL JOISTS THAT ARE SITTING IN THE POCKET ARE ROTTED AND DETERIORATING PROVIDE A STRUCTURAL ENGINEERS REPORT TO DETERMINE STRUCTURAL STABILITY AND REPAIRS TO BE MADE TEMP LALLY COLUMNS ARE NOT PERMITTED FOR PERMANENT USE 14X-1-104.1 3636 W 111TH ST COMPLAINT FAILED View
PERMIT REQUIRED - CONTRACTOR A PERMIT IS REQUIRED FOR REPAIRS MADE ACCORDING TO THE STRUCTURAL ENGINEERS REPORT 14A-4-401.1 3636 W 111TH ST COMPLAINT FAILED View
OBTN PERMIT FOR PLUMBING WORK OBTAIN PLUMBING PERMIT FOR PLUMBING WORK TO BE PERFORMED 3636 W 111TH ST COMPLAINT FAILED View
INDIRECT CONN.FOR WATER SUPPLY NO CHECK VALVE AT CO-2 SODA MACHINE LOCATED IN BASEMENT DANGEROUS AND HAZARDOUS 3636 W 111TH ST COMPLAINT FAILED View
INDIRECT CONN.FOR WATER SUPPLY NO CHECK VALVE AT ICE MACHINE LOCATED IN BASEMENT DANGEROUS AND HAZARDOUS 3636 W 111TH ST COMPLAINT FAILED View
SOIL/WASTE,VENT PIPE MATRL PVC LOCATED ON HAND SINK BEHIND BAR 1ST FLOOR AND BAR GARDEN REAR 3636 W 111TH ST COMPLAINT FAILED View
PRV FLOOR DRAIN WITH METAL STR BATHROOM BASEMENT HAS NO FLOOR DRAIN 3636 W 111TH ST COMPLAINT FAILED View
SUBMIT REVISED PLANS FOR PERMT PATIO BAR INSTALLED WITHOUT PLANS AND PERMIT 3636 W 111TH ST COMPLAINT FAILED View
ADD RECEPTACLES ADD ADDITIONAL RECEPTACLES THROUGHOUT IN ORDER TO ELIMINATE OVER USE OF CORDS THROUGHOUT SPECIFICALLY FOR ALL AMUSEMENT EQUIPMENT AND ON THE EXTERIOR FOR FESTOON TYPE LIGHTING IN BEER GARDEN DANGEROUS AND HAZARDOUS 3636 W 111TH ST COMPLAINT FAILED View
CONTINUITY OF RACEWAYS PROVIDE PROPER CONTINUITY OF ALL RACEWAYS THROUGHOUT BY TIGHTENING ALL LOOSE FITTING SPECIFICALLY THROUGHOUT BASEMENT DANGEROUS AND HAZARDOUS 3636 W 111TH ST COMPLAINT FAILED View
RESTORE EXIT AND EM RESTORE ALL EXIT SIGNS AND EM LIGHTING THROUGHOUT 1ST FLOOR BAR AREA ALONG WITH BATHROOM WHICH WERE ALL INOPERABLE DANGEROUS HAZARDOUS 3636 W 111TH ST COMPLAINT FAILED View
SECURE RACEWAY PROPERLY SECURE ALL CONDUITS AND BOXES THROUGHOUT THE BASEMENT 3636 W 111TH ST COMPLAINT FAILED View
LISTED FOR USE TEMP & LOCATION INSTALL PROPER BRANCH CIRCUIT BREAKERS WHICH ARE LISTED FOR USE BY PANEL MANUFACTURER INSTALL PROPER JUNCTION BOXES WHICH ARE LISTED FOR USE IN DAMP/WET LOCATIONS INSIDE WALK-IN COOLER IN THE BASEMENT DANGEROUS AND HAZARDOUS 3636 W 111TH ST COMPLAINT FAILED View
CLOSE BOX OPENINGS INSTALL KO FILLERS IN ALL OPEN UNUSED OPENINGS IN JUNCTION BOXES THROUGHOUT THE BASEMENT DANGEROUS AND HAZARDOUS 3636 W 111TH ST COMPLAINT FAILED View
UNAPPROVED CORDS REMOVE ALL EXTENSION CORDS THROUGHOUT INTERIOR AND EXTERIOR (BEER GARDEN) BEING USED TO PERMANENT FIXED ELECTRICAL EQUIPMENT DANGEROUS AND HAZARDOUS 3636 W 111TH ST COMPLAINT FAILED View
INSTALL GFCI'S PROVIDE GFCI PROTECTION TO ALL REQUIRED RECEPTACLES THROUGHOUT SPECIFICALLY IN EXTERIOR BEER GARDEN AREA DANGEROUS AND HAZARDOUS 3636 W 111TH ST COMPLAINT FAILED View
SEE INSPECTOR COMMENTS PROVIDE ELECTRICAL PERMIT IN ORDER TO CORRECT ELECTRICAL VIOLATIONS (14A-4-404.6) 3636 W 111TH ST COMPLAINT FAILED View
1HR FLR OVER BSMT, 1 OR 2 DU MISSING SECTIONS OF DRYWALL AT BASEMENT IN VARIOUS LOCATIONS A 1 HOUR FIRE SEPARATION IS REQUIRED 14B-6-605.4 DANGEROUS AND HAZARDOUS 3636 W 111TH ST COMPLAINT FAILED View
MIXED OCCUPANCY SEPARATION MISSING FIRE SEPARATION AT 1ST FLOOR UNTILITY CLOSET CEILING A 1 HOUR FIRE SEPARATION IS REQUIRED 14B-5-508 DANGEROUS AND HAZARDOUS 3636 W 111TH ST COMPLAINT FAILED View