Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
OPEN | 6146 S MAY ST | PERMIT | FAILED | View | |
REPAIR EXTERIOR WALL | ENCLOSED PORCH - SIDING LOOSE AND MISSING SECTIONS. | 6146 S MAY ST | COMPLAINT | FAILED | View |
CHIMNEY CAPPING | CHIMNEY - MISSING CAPPING. | 6146 S MAY ST | COMPLAINT | FAILED | View |
REPAIR WINDOW SILLS | 3RD FLOOR - WINDOW SILLS SHIFTED AND OPEN MORTAR JOINTS. | 6146 S MAY ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | FRONT ENTRANCE - DOOR PANES BROKEN. | 6146 S MAY ST | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | 1ST FLOOR - WINDOW PANES BROKEN. | 6146 S MAY ST | COMPLAINT | FAILED | View |
MAINTAIN WINDOW SASH | 1-3RD FLOOR - WINDOW SASHES ROTTING AND PEELING PAINT. | 6146 S MAY ST | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | 3RD FLOOR - WINDOW FRAMES ROTTING AND BROKEN. | 6146 S MAY ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BLDG: ENTRY REFUSED BY BUILDING MAINTENANCE ENGINEER - UNVERIFIED DETECTORS AND CONDITIONS. UNABLE TO INSPECT REAR ENCLOSED PORCH. | 6146 S MAY ST | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BLDG. - MISSING OWNER'S I.D. SIGN. | 6146 S MAY ST | COMPLAINT | FAILED | View |
SUBMIT FOR APPROVAL PLANS | 6146 S MAY ST | COMPLAINT | CLOSED | View | |
MAINTAN BLDG IN SAFE CONDITION | 6146 S MAY ST | COMPLAINT | CLOSED | View | |
VACANT BUILDING - REGISTER | 6146 S MAY ST | COMPLAINT | CLOSED | View | |
POST OWNER INFO ON ABDN BLDG | 6146 S MAY ST | COMPLAINT | CLOSED | View | |
FILE BLDG REGISTRATION | BLDG. - NOT REGISTERED FROM 2006 THRU 2011. | 6146 S MAY ST | COMPLAINT | FAILED | View |
RMV PLBFIX INSTALLD W/0 PERMIT | PLUMBER ON RECORD DID NOT DO ANY WORK.(13-168-040 THRU 060) (11-8-070) (13-32-010)(13-12-050) (13-168-030) | 6146 S MAY ST | COMPLAINT | FAILED | View |
OPEN | 6146 S MAY ST | PERMIT | FAILED | View | |
SUBMIT FOR APPROVAL PLANS | 6146 S MAY ST | COMPLAINT | CLOSED | View | |
MAINTAN BLDG IN SAFE CONDITION | 6146 S MAY ST | COMPLAINT | CLOSED | View | |
REPAIR/WRECK DANGER RESID PREM | 6146 S MAY ST | COMPLAINT | CLOSED | View | |
VACANT BUILDING - REGISTER | 6146 S MAY ST | COMPLAINT | CLOSED | View | |
POST OWNER INFO ON ABDN BLDG | 6146 S MAY ST | COMPLAINT | CLOSED | View | |
ARRANGE COMPLETED PERMIT INSP. | 6146 S MAY ST | PERMIT | FAILED | View | |
OBTN PERMIT FOR PLUMBING WORK | (18-29-106.1) (13-168-060) | 6146 S MAY ST | COMPLAINT | FAILED | View |
LICENSED BONDED PLMBG CONTRCTR | 1(4-332-010-100) (18-29-106.2) (13-168-070) | 6146 S MAY ST | COMPLAINT | FAILED | View |
WATCHMAN | 6146 S MAY ST | COMPLAINT | CLOSED | View | |
WATCHMAN | 6146 S MAY ST | COMPLAINT | CLOSED | View | |
REPAIR/WRECK DANGER RESID PREM | 6146 S MAY ST | COMPLAINT | CLOSED | View | |
HEAT UNIT ADEQUATELY | WHILE 26DEG.F OUTSIDE AT 3:42PM IN APARTMENT 1F AND WITH THE THERMOSTAT LOCKED AND SET ON 70DEG.F IN THE WARMEST LOCATION - THE AIR TEMPERATURE IN THE THE LIVING ROOM WAS 66DEG.F AND THE REAR BEDROOM WAS 65DEG.F (14X-8-802.2, 14X-8-802.2.1 AND 14X-8-802.2.2) | 6146 S MAY ST | COMPLAINT | FAILED | View |
REPAIR CATCH BASIN | REAR / CATCH BASIN - CRACKED. | 6146 S MAY ST | COMPLAINT | PASSED | View |
STOP/REMOVE NUISANCE | FRONT / NUISANCE - OVER GROWN TREE BRANCHES ON THE ROOF . | 6146 S MAY ST | COMPLAINT | PASSED | View |
REPAIR ROOF | REAR PORCH / ROOF - OPEN 2X2FT HOLE | 6146 S MAY ST | COMPLAINT | PASSED | View |
PARAPET | NORTH ELEVATION / PARAPET - WASHED OUT MORTAR . | 6146 S MAY ST | COMPLAINT | PASSED | View |
REPAIR FENCE | REAR / NEW WODEN FENCE - 50X6 FT HIGH PERMIT REQUIRED FOR FENCE . | 6146 S MAY ST | COMPLAINT | PASSED | View |
UNAPPROVED HEATING DEVICE | APARTMENT 1F - KITCHEN STOVE AND EXTENSIVE USE OF PORTABLE PLUG-IN SPACE HEATERS FOR SUPPLEMENTAL HEAT (14X-8-802.2) | 6146 S MAY ST | COMPLAINT | FAILED | View |
HEAT UNIT ADEQUATELY | WHILE 26DEG.F OUTSIDE AT 3:42PM IN APARTMENT 1F AND WITH THE THERMOSTAT LOCKED AND SET ON 70DEG.F IN THE WARMEST LOCATION - THE AIR TEMPERATURE IN THE THE LIVING ROOM WAS 66DEG.F AND THE REAR BEDROOM WAS 65DEG.F (14X-8-802.2, 14X-8-802.2.1 AND 14X-8-802.2.2) | 6146 S MAY ST | COMPLAINT | CLOSED | View |
UNAPPROVED HEATING DEVICE | APARTMENT 1F - KITCHEN STOVE AND EXTENSIVE USE OF PORTABLE PLUG-IN SPACE HEATERS FOR SUPPLEMENTAL HEAT (14X-8-802.2) | 6146 S MAY ST | COMPLAINT | CLOSED | View |
MAINTAIN WINDOW | SOUTH ELEVATION / WINDOWS - BOARD UP | 6146 S MAY ST | COMPLAINT | PASSED | View |
REPAIR PORCH SYSTEM | REAR / EXTERIOR PORCH -GRADE TO 2ND FL .6X6/4X4 COLUMNS ERECTED ON SERVICE WALK.1/2 LAP MISSING BOLTS AND INDER SIZED .LANDING JOIST NAILED TO HEADERS .1ST FL TREAD MISSING .GUARDRAILS AND STRINGERS NAILED ONLY TO COLMNS ,HEADERS AND WALL .2X4 USED FOR POST ON 2ND FL PICKETS MISSING 1ST FL .PLANS AND PERMIT REQUIRED TO REPAIR REAR PORCH . | 6146 S MAY ST | COMPLAINT | PASSED | View |
REPAIR EXTERIOR WALL | NORTH AND SOUTH ELEVATION / EXTERIOR WALL - WASHED OUT MORTAR .NORTH ELEVATION STONE AND BRICK PULLING AWAY FROM WALL 1/2 GAPS.SOUTH ELEVATION LARGE SECTION BRICKS MISSING AND SPALLING BRICKS .PERMIT REQUIRED TO REPAIR EXTERIOR WALL . | 6146 S MAY ST | COMPLAINT | PASSED | View |
REPAIR EXTERIOR STAIR | FRONT / EXTERIOR STAIR - GUARDRAILS TOE NAILED ONLY TO COLUMNS AND NAILED TO WALL | 6146 S MAY ST | COMPLAINT | PASSED | View |
FOUNDATION, ADEQUATELY SUPPORT | REAR /RETANINING WALL - LEAN OUT 10 INCH IN 3FT HIGH . | 6146 S MAY ST | COMPLAINT | PASSED | View |