PLANS & PERMITS REQ - CONTRCTR | PROVIDE PLANS FOR WALLS FORMING ROOMS, KITCHEN AND BATH IN BASEMENT DWELLING | 3744 W 57TH PL | COMPLAINT | FAILED | View |
CEILING HEIGHT - 7' - BASEMENT | BASEMENT DWELLING HAS LOW CEILING LESS THAN 7 FEET 6'6' | 3744 W 57TH PL | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | PROVIDE PERMITS AND PLANS FOR PARTITION WALLS IN ATTIC | 3744 W 57TH PL | COMPLAINT | FAILED | View |
CEILING HEIGHT 7FT EXIST BLDGS | ATTIC CEILING HEIGHT 6' LESS THAN REQUIRED HEIGHT FOR SLEEPING ROOMS | 3744 W 57TH PL | COMPLAINT | FAILED | View |
ATTIC, DISCONTINUE | ATTIC INADEQUATE NATURAL LIGHT FOR DWELLING AND INADEQUATE NATURAL VENTILATION (WORKING IN PROGRESS TO COMPLETE ROOMS) | 3744 W 57TH PL | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO BASEMENT, ATTIC, 1ST FRONT AND GARAGE (ORIGINAL TWO CAR GARAGE ALTERED INTO A DWELLING UNIT.) | 3744 W 57TH PL | COMPLAINT | FAILED | View |
PROVID SELF CLSING SCREEN DVCE | FRONT BASEMENT AND 1ST FLOOR STORM DOORS - MISSING SELF-CLOSERS. | 3744 W 57TH PL | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | SOUTH ELEVATION - STEP CRACK; WEST ELEVATION - SPALLING BRICKS.; GARAGE - WASHED OUT MORTAR. | 3744 W 57TH PL | COMPLAINT | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | INTERIOR STAIRS 1ST TO ATTIC, KNEE WALL EXPOSED WOOD LATH. | 3744 W 57TH PL | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | ATTIC - MISSING CARBON MONOXIDE DETECTOR. | 3744 W 57TH PL | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | FRONT EXTERIOR STAIRS GRADE TO BASEMENT, GUARDRAILS ARE APROX. 16" HIGH AND MISSING GUARDRAILS. | 3744 W 57TH PL | COMPLAINT | FAILED | View |
EGRESS -BASEMENT | BASEMENT APARTMENT, REAR EXIT IS THRU BASEMENT STORAGE ROOM. | 3744 W 57TH PL | COMPLAINT | FAILED | View |
REPAIR LINTELS | SOUTH BASEMENT 8'-8" WINDOW AND DOOR LINTEL IS RUSTED AND SAGGING - PLANS AND MASONRY PERMIT REQUIRED TO REPLACE LINTEL. | 3744 W 57TH PL | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | REMOVE ALL PARTITIONS AND FIXTURES INCLUDING PLUMBING AND ELECTRIC INSTALLED IN THE BASEMENT WITHOUT A PERMIT. | 3744 W 57TH PL | COMPLAINT | FAILED | View |
CEILING HEIGHT - 7' - BASEMENT | BASEMENT APARTMENT, CEILING HEIGHT IS 6'-9". | 3744 W 57TH PL | COMPLAINT | FAILED | View |
REPAIR/REBUILD GARAGE OR SHED | GARAGE - WASHED OUT MORTAR. | 3744 W 57TH PL | COMPLAINT | FAILED | View |
PROVID SELF CLSING SCREEN DVCE | SOUTH BASEMENT STORM DOOR - MISSING SELF-CLOSER. | 3744 W 57TH PL | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO THE BASEMENT OR RESTORE THE BUILDING TO THE ORIGINAL STATE. | 3744 W 57TH PL | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | BASEMENT - MISSING CARBON MONOXIDE DETECTOR. | 3744 W 57TH PL | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | SOUTH BASEMENT STORM DOOR - BROKEN AND MISSING PLEXI-GLASS PANES. | 3744 W 57TH PL | COMPLAINT | FAILED | View |
REPAIR/REPLACE SMOKE DETECTORS | BASEMENT SMOKE DETECTOR - MISSING BATTERY. | 3744 W 57TH PL | COMPLAINT | FAILED | View |
DEFECTIVE DISTRIBUTION | LIGHT FLICKERING 1ST FLOOR REAR. | 3744 W 57TH PL | COMPLAINT | FAILED | View |
EXPOSED WIRING | ATTIC | 3744 W 57TH PL | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | 1ST FLOOR REAR APARTMENT 79° BOILER HEAT. | 3744 W 57TH PL | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | 2ND FLOOR REAR APARTMENT 68° ELECTRICAL BASEBOARDS HEAT. MISSING SMOKE AND CARBON MINOXIDE DETECTORS TRANSFER TO ELECTRIC. FOR EXPOSED WIRING 2ND FLOOR ELECTRIC BASEBOARDS. | 3744 W 57TH PL | COMPLAINT | FAILED | View |
NO PERMIT WIRING | ATTIC BUILD OUT ELECTRICAL HEATERS AND RECEPTACLES. | 3744 W 57TH PL | COMPLAINT | FAILED | View |
CIRCUIT 1 UNIT ONLY | INSTALL PUBLIC METER AND PANEL FOR COMMON AREA. | 3744 W 57TH PL | COMPLAINT | FAILED | View |
INSTALL COVERS | ATTIC | 3744 W 57TH PL | COMPLAINT | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | FRONT EXTERIOR STAIRS GRADE TO BASEMENT, GUARDRAILS ARE ONLY 17-1/2" AND MISSING GUARDRAILS. | 3744 W 57TH PL | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | REMOVE ALL PARTITIONS AND FIXTURES INCLUDING PLUMBING AND ELECTRIC INSATALLED IN THE BASEMENT, 1ST FRONT, ATTIC AND GARAGE. WITHOUT A PERMIT. | 3744 W 57TH PL | COMPLAINT | FAILED | View |
CEILING HEIGHT - 7' | ATTIC CEILING HEIGHT IS 6'-4-1/2". | 3744 W 57TH PL | COMPLAINT | FAILED | View |
REPAIR LINTELS | SOUTH BASEMENT DOOR AND WINDOW LINTEL - RUSTED AND BENT. PLANS AND MASONRY PERMIT REQUIRED TO REPLACE LINTEL. | 3744 W 57TH PL | COMPLAINT | FAILED | View |
CEILING HEIGHT - 7' - BASEMENT | BASEMENT APT., CEILING HEIGHT IS 6'-9". | 3744 W 57TH PL | COMPLAINT | FAILED | View |
LIGHT AND VENT | ATTIC WITH 2 BEDROOMS AND LIVINGROOM HAS TWO WINDOWS ONLY. | 3744 W 57TH PL | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | FRONT PORCH STAIRS - ERODED MORTAR. | 3744 W 57TH PL | COMPLAINT | FAILED | View |
EGRESS -BASEMENT | BASEMENT APARTMENT, REAR EXIT IS THRU BASEMENT STORAGE ROOM. | 3744 W 57TH PL | COMPLAINT | FAILED | View |