Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
INSTALL SMOKE DETECTORS | MISSING SMOKE DETECTORS AT 4851 1ST FLOOR AND BASEMENT - DANGEROUS AND HAZARDOUS. | 4851 W CHICAGO AVE | COMPLAINT | CLOSED | View |
CARB MONOX DETECT IN RESID | MISSING CARBON MONOXIDE DETECTORS AT 4851 1ST FLOOR AND BASEMENT - DANGEROUS AND HAZARDOUS. | 4851 W CHICAGO AVE | COMPLAINT | CLOSED | View |
OBSTRUCTIONS IN EXIT WAY | VARIOUS AISLES AT 4851 REDUCED IN SIZE RANGING FROM 22" TO 33" - DANGEROUS AND HAZARDOUS. 1(15-4-900) | 4851 W CHICAGO AVE | COMPLAINT | CLOSED | View |
FIRE EXTNGSHR RECHARGE & TAG | FIRE EXTINGUISHER AT 4851 WITH EXPIRED TAGS. | 4851 W CHICAGO AVE | COMPLAINT | CLOSED | View |
STRUCTURAL MEMBER, PIER BLOCK | SEVERAL ROTTED JOISTS (BETWEEN 4-6) AT SOUTHWEST ELEVATION BASEMENT 4851. | 4851 W CHICAGO AVE | COMPLAINT | CLOSED | View |
REPAIR INTERIOR STAIR SYSTEM | INTERIOR STAIR SYSTEM LEADING TO BASEMENT DIFFERENT SIZE RISER HEIGHTS RANGING FROM 4 1/2" TO 8 1/2". DANGEROUS AND HAZARDOUS - 4851. | 4851 W CHICAGO AVE | COMPLAINT | CLOSED | View |
REPAIR OR REPLACE | RAISED PLATFORM AT 4851 EAST ELEVATION BUILT WITHOUT PLANS AND PERMITS, ROUGHLY 200 SQ. FT. - 10" TALL. PROPER FIRE STOPPING IS REQUIRED. (15-8-460) DANGEROUS AND HAZARDOUS. | 4851 W CHICAGO AVE | COMPLAINT | CLOSED | View |
REPAIR FLOOR | TILE CHIPPED/BROKEN AT 4851 1ST FLOOR AT VARIOUS DIFFERENT LOCATIONS WHICH CAUSE A TRIP HAZARD. 1ST FLOOR REAR SOUTH ELEVATION FLOOR DEFLECTS UNDER LOAD. | 4851 W CHICAGO AVE | COMPLAINT | CLOSED | View |
REPAIR OR REPLACE | ENTIRE BASEMENT CEILING AT 4851 EXPOSED WOOD JOISTS. NEEDS PROPER FIRE SEPARATION INCLUDING DRYWALL, FIRE TRAP AND FIRE CAULK. (13-56-280) DANGEROUS AND HAZARDOUS. | 4851 W CHICAGO AVE | COMPLAINT | CLOSED | View |
PERMIT REQUIRED - CONTRACTOR | PERMIT REQUIRED FOR ALL DRYWALL RELATED WORK. | 4851 W CHICAGO AVE | COMPLAINT | CLOSED | View |
REPAIR OR REPLACE | HEATING PLANT AT 4851 1ST FLOOR EAST ELEVATION DOES NOT HAVE PROPER FIRE SEPARATION. DRYWALL ON ONE SIDE OF WALL, OPEN STUDDING ON THE OTHER SIDE. (13-60-200) DANGEROUS AND HAZARDOUS. | 4851 W CHICAGO AVE | COMPLAINT | CLOSED | View |
PROPER MATRL WATER SUPPLY PIPE | 4851 BACK ROOM - BOTH BATHROOMS, REMOVE FLEX WATER SUPPLIES AND INSTALL COPPER SUPPLIES TO ALL FIXTURES. | 4851 W CHICAGO AVE | COMPLAINT | CLOSED | View |
ENGAG LIC & BOND PLMBNG CNTRC | HIRE A LICENSED PLUMBING CONTRACTOR. | 4851 W CHICAGO AVE | COMPLAINT | CLOSED | View |
REPLACE DEFECTIVE WATER PIPING | 4851 BACK ROOM - BOTH BATHROOMS, INSTALL AIR CHAMBERS ON WATER LINES TO ALL FIXTURES. | 4851 W CHICAGO AVE | COMPLAINT | CLOSED | View |
OBTN PERMIT FOR PLUMBING WORK | PULL A PLUMBING PERMIT. | 4851 W CHICAGO AVE | COMPLAINT | CLOSED | View |
SOIL/WASTE,VENT PIPE MATRL | 4851 BACK ROOM - BOTH BATHROOMS, REMOVE PVC TRAPS AND INSTALL BRASS TRAPS. | 4851 W CHICAGO AVE | COMPLAINT | CLOSED | View |
INSTALL VENT PIPE FOR TRAP | 4851 BACK ROOM - INSTALL VENT PIPING FOR HAND SINK TRAP BY THREE COMPARTMENT SINK. | 4851 W CHICAGO AVE | COMPLAINT | CLOSED | View |
PRV DISCHARGE PIPE FROM PRV | 4851 WATER HEATER - INSTALL METALLIC RELIEF VALVE PIPING TO FLOOR. | 4851 W CHICAGO AVE | COMPLAINT | CLOSED | View |
PRV FLUE FOR HOT WATER HEATER | 4851 - REATTACH DIVERTER AND FLUE PIPE TO TOP OF WATER HEATER. THE PIPING IS 3" OFF OF HEATER. | 4851 W CHICAGO AVE | COMPLAINT | CLOSED | View |
REPLACE DEFECTIVE WASTE PIPING | 4851 FIRST FLOOR - INSTALL 1-1/2" WASTE PIPING FOR HAND SINK AT FRONT OF STORE NORTHWEST CORNER, WITH PROPER PITCH BACK TO THE 4" SOIL STACK IN BASEMENT. | 4851 W CHICAGO AVE | COMPLAINT | CLOSED | View |
INSTALL VENT PIPE FOR TRAP | 4851 - SOUTH END OF BASEMENT, REMOVE 2" SOIL LINE FROM THE HEEL INLET ELL PICKING UP THE TOILET AND RE-PIPE TO 4" HORIZONTAL SOIL LINE AT CEILING. THE 2" LINE IS WET VENTING TOILET LINE. | 4851 W CHICAGO AVE | COMPLAINT | CLOSED | View |
PRV CLEANOUT AT BASE OF STACK | 4851 BASEMENT - INSTALL A FULL SIZED CLEAN OUT AT THE BASE OF THE SOIL STACK. | 4851 W CHICAGO AVE | COMPLAINT | CLOSED | View |
PROPER SIZE SOIL/WASTE STACK | 4851 FIRST FLOOR - INSTALL A VENT PIPE FOR HAND SINK AT THE FRONT OF STORE NORTHWEST CORNER. | 4851 W CHICAGO AVE | COMPLAINT | CLOSED | View |
PROVIDE INDIRECT WASTE CONNECT | 4851 FIRST FLOOR - DISCONNECT CONDENSATE WASTE PIPE FROM COOLER AT FRONT OF STORE AND INSTALL A INDIRECT WASTE WITH A "P" TRAP PROPERLY VENTED. | 4851 W CHICAGO AVE | COMPLAINT | CLOSED | View |
EXPOSED WIRING | 4851 - REMOVE EXPOSED WIRING IN BASEMENT TO COMPRESSOR AND PROPERLY MAKE CONNECTION TO MOTOR - DANGEROUS. | 4851 W CHICAGO AVE | COMPLAINT | CLOSED | View |
INSTALL COVERS | 4851 - INSTALL COVERS TO ALL OPEN DEVICES AND JUNCTION BOXES - DANGEROUS CONDITION. | 4851 W CHICAGO AVE | COMPLAINT | CLOSED | View |
SYSTEM III | 4851 - INSTALL CHICAGO APPROVED EXIT SIGNS AND EMERGENCY LIGHTS - DANGEROUS. | 4851 W CHICAGO AVE | COMPLAINT | CLOSED | View |
OBTAIN PERMIT BEFORE SIGN WORK | ONE BUILDING MOUNTED FLAT 20 X 2' SIGN READS "MORE FOR LESS" 13-20-520 AND 13-20-550 | 4851 W CHICAGO AVE | COMPLAINT | FAILED | View |
OPEN | 4851 - INSTALL SAFE PAN UNDER WATER HEATER. (18-29-504.8) | 4851 W CHICAGO AVE | COMPLAINT | CLOSED | View |
(13-12-360) PROVIDE PERMIT TO CORRECT VIOLATIONS. | 4851 W CHICAGO AVE | COMPLAINT | CLOSED | View | |
ARRANGE PREMISE INSPECTION | NO ENTRY TO 2ND FLOOR RESIDENTIAL UNITS AND COMMERCIAL SPACE OTHER THAN 4851 W. CHICAGO. | 4851 W CHICAGO AVE | COMPLAINT | CLOSED | View |
OPEN | 4851 - INSTALL A FLOOR DRAIN FOR THE WATER HEATER. (18-29-504.8.2) | 4851 W CHICAGO AVE | COMPLAINT | CLOSED | View |
UNAPPROVED CORDS | 4851 - REMOVE UNAPPROVED EXTENSION CORDS THROUGHOUT STORE INCLUDING IN BASEMENT PENETRATING 1ST FLOOR - DANGEROUS. | 4851 W CHICAGO AVE | COMPLAINT | CLOSED | View |