The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING, NO RESPONSE, UNVERIFIED OCCUPANCY AND DETECTORS, UNABLE TO INSPECT REAR PORCH | 2651 W DIVISION ST | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | MISSING OWNERS I.D. SIGN | 2651 W DIVISION ST | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO 2ND AND 3RD FLR. | 2651 W DIVISION ST | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH;NO FOOTINGS,REPLACE 4X4 UPRIGHTS WITH 6X6S,HAND RAILS LOOSE,TREADS WARP AND SPLIT,STRINGER TO LONG OF A RUN.SUBMIT PLANS AND PERMITS | 2651 W DIVISION ST | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | POST OWNERSHIP ON BUILDING | 2651 W DIVISION ST | PERIODIC | FAILED | View |
REPAIR FLOOR | 3RD FLR.APARTMENT BATHROOM FLOOR; SINKING IN | 2651 W DIVISION ST | PERIODIC | FAILED | View |
EXPOSED WIRING FIXTURES | 2ND FLR.APARTMENT MIDDLE BEDROOM CLOSET LIGHT FIXTURE;EXPOSED WIRING | 2651 W DIVISION ST | PERIODIC | PASSED | View |
REPAIR EXTERIOR STAIR | SOUTH ELEVATION - EXTIRIOR STAIRS, 4X4 COLUMNS DOUBLE CUT FOR BEAMS, STRINGERS NAILED TO COLUMNS AND FLOOR JOISTS. PERMIT FOR REPAIRS | 2651 W DIVISION ST | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING OWNER'S ID SIGN NOT POSTED. | 2651 W DIVISION ST | COMPLAINT | FAILED | View |
REPAIR DOOR HARDWARE | FOYER DOOR;DOOR KNOB MISSING | 2651 W DIVISION ST | PERIODIC | PASSED | View |
WINDOW REPAIR FOR AIR SEEPAGE | 2ND AND 3RD FLR.WINDOW;AIR-SEEPAGE | 2651 W DIVISION ST | COMPLAINT | FAILED | View |
HEAT UNIT ADEQUATELY | 2ND AND 3RD FLR.NO HEAT 60DG. | 2651 W DIVISION ST | COMPLAINT | FAILED | View |
SAFE WORKING CONDITIONS | 2ND FLR.HAS NO ELECTRICITY IN HALF OF THE APARTMENTS, 2ND FLR.APARTMENT ELECTRICTIY IS ILLEGALY HOOK UP TO 3RD FLR.APARTMENT.3RD FLR.ELECTRICITY SHUT OFF UNPAID BILL. | 2651 W DIVISION ST | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | 2ND AND 3RD FLR.,INTERIOR STAIR;NO SMOKE DETECTORS | 2651 W DIVISION ST | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | 2ND AND 3RD FLR.APARTMENT NO CARBON MONOXIDE | 2651 W DIVISION ST | COMPLAINT | FAILED | View |
NO KEY TO USE EXIT DOOR | REAR IRON GATE;KEYLOCK | 2651 W DIVISION ST | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | WEST EXTERIOR CENTER COVE TIN WALL ;RUSTED | 2651 W DIVISION ST | PERIODIC | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | 2ND FLR.APARTMENT FURNACE ROOM HOLE IN DRYWALL,FURNACE ROOM CEILING WATER DAMAGE,BATHROOM CEILING WATER DAMAGE,BATHROOM TUB WALL TILES BUCKLING,KITCHEN CEILING DRYWALL BUCKLING,HOLE IN BATHROOM DRYWALL. 3RD FLR.ENCLOSE PORCH CEILING TILES WATER DAMAGE | 2651 W DIVISION ST | PERIODIC | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | 3RD FLR.ENCLOSE PORCH WINDOW PANE;BROKEN | 2651 W DIVISION ST | PERIODIC | FAILED | View |
WINDOW REPAIR FOR AIR SEEPAGE | 2ND AND 3RD FLR.ALL ELEVATION WINDOW;AIR-SEEPAGE | 2651 W DIVISION ST | PERIODIC | FAILED | View |
REPAIR DOOR, INT. | 3RD FLR.APARTMENT BATHROOM DOOR;BROKEN | 2651 W DIVISION ST | PERIODIC | FAILED | View |
REPAIR DOOR FRAME, MULLION | 2ND FLR.APARTMENT KITCHEN ENTRANCE DOOR FRAME TRANSOM PANE BROKEN,BATHROOM DOOR FRAME,MIDDLE BEDROOM DOOR FRAME AND APARTMENT DOOR FRAME;BROKEN. 3RD FLR.APARTMENT KITCHEN DOOR FRAME,APARTMENT DOOR FRAME;BROKEN | 2651 W DIVISION ST | PERIODIC | FAILED | View |
REPAIR DOOR HARDWARE | FOYER DOOR;DOOR KNOB MISSING | 2651 W DIVISION ST | PERIODIC | FAILED | View |
INSTALL DEAD BOLT LOCK | 3RD FLR.APARTMENT KITCHEN DOOR;NO LOCK | 2651 W DIVISION ST | PERIODIC | FAILED | View |
PROVIDE DEADLOCK FOR ENTRANCE | NORTH EXTERIOR DOOR LOCK;BROKEN [STICKS] | 2651 W DIVISION ST | PERIODIC | FAILED | View |
CARPETING | 3RD FLR.APARTMENT CARPET;UNSANITARY | 2651 W DIVISION ST | PERIODIC | FAILED | View |
INSTALL SMOKE DETECTORS | INTERIOR STAIR,2ND AND 3RD FLR.APARTMENTS;NO SMOKE DETECTORS | 2651 W DIVISION ST | PERIODIC | FAILED | View |
CARB MONOX DETECT IN RESID | 2ND AND 3RD FLR.APARTMENTS;NO CARBON MONOXIDE | 2651 W DIVISION ST | PERIODIC | FAILED | View |
EXPOSED WIRING FIXTURES | 2ND FLR.APARTMENT MIDDLE BEDROOM CLOSET LIGHT FIXTURE;EXPOSED WIRING | 2651 W DIVISION ST | PERIODIC | FAILED | View |
INSTALL COVERS | 2ND FLR.APARTMENT REAR BEDROOM WALL OUTLET,BATHROOM LIGHT SWITCH;NO COVER PLATES 1ST FLR.BATHROOM WALL OUTLET;NO COVER PLATE | 2651 W DIVISION ST | PERIODIC | FAILED | View |
EXPOSED WIRING | 1ST FLR.HALLWAY CEILING;EXPOSED WIRING 3RD FLR.FURNACE ROOM CEILING;EXPOSED WIRING | 2651 W DIVISION ST | PERIODIC | FAILED | View |
PERMIT REQUIRED | NO PERMIT FOR IRON GATE AND IRON FENCE | 2651 W DIVISION ST | PERIODIC | FAILED | View |
REPLACE DEFECTIVE TRAP | 2ND AND 3RD FLR.APARTMENTS KITCHEN SINK TRAPS;LEAKS | 2651 W DIVISION ST | PERIODIC | FAILED | View |
STOP LEAKING WATER | 2ND FLR.APARTMENT FURNACE ROOM CEILING,KITCHEN CEILING;AND BATHROOM CEILING;LEAKS | 2651 W DIVISION ST | PERIODIC | FAILED | View |
RESET LOOSE FIXTURE | 3RD FLR.APARTMENT BATHROOM TOLIET;LOOSE 1ST FLR.BATHROOM SINK;HANGING OFF THE WALL [NO SUPPORTS] | 2651 W DIVISION ST | PERIODIC | FAILED | View |
KEEP FIXTUR CLEAN AND SANITARY | 2ND FLR.APARTMENT BATHROOM TUB;PAINT CHIPS 3RD FLR.APARTMENT BATHROOM TUB;RUSTED | 2651 W DIVISION ST | PERIODIC | FAILED | View |
NO KEY TO USE EXIT DOOR | REAR IRON GATE;KEYLOCK | 2651 W DIVISION ST | PERIODIC | PASSED | View |
OBSTRUCTIONS IN EXIT WAY | REAR IRON FENCE;PADLOCK | 2651 W DIVISION ST | PERIODIC | PASSED | View |
REPAIR EXTERIOR WALL | WEST EXTERIOR CENTER COVE TIN WALL ;RUSTED | 2651 W DIVISION ST | PERIODIC | PASSED | View |
REPAIR PORCH SYSTEM | REAR PORCH;NO FOOTINGS,REPLACE 4X4 UPRIGHTS WITH 6X6S,HAND RAILS LOOSE,TREADS WARP AND SPLIT,STRINGER TO LONG OF A RUN.SUBMIT PLANS AND PERMITS | 2651 W DIVISION ST | PERIODIC | PASSED | View |
REPAIR INTERIOR WALLS/CEILING | 2ND FLR.APARTMENT FURNACE ROOM HOLE IN DRYWALL,FURNACE ROOM CEILING WATER DAMAGE,BATHROOM CEILING WATER DAMAGE,BATHROOM TUB WALL TILES BUCKLING,KITCHEN CEILING DRYWALL BUCKLING,HOLE IN BATHROOM DRYWALL. 3RD FLR.ENCLOSE PORCH CEILING TILES WATER DAMAGE | 2651 W DIVISION ST | PERIODIC | PASSED | View |
REPAIR FLOOR | 3RD FLR.APARTMENT BATHROOM FLOOR; SINKING IN | 2651 W DIVISION ST | PERIODIC | PASSED | View |
STRUCTURAL MEMBER, PIER BLOCK | BASEMENT WOOD COLUMNS ROTTED AT THE BASE [PERMITS FOR REPAIRS] | 2651 W DIVISION ST | PERIODIC | PASSED | View |
WINDOW REPAIR FOR AIR SEEPAGE | 2ND AND 3RD FLR.ALL ELEVATION WINDOW;AIR-SEEPAGE | 2651 W DIVISION ST | PERIODIC | PASSED | View |
REPAIR DOOR, INT. | 3RD FLR.APARTMENT BATHROOM DOOR;BROKEN | 2651 W DIVISION ST | PERIODIC | PASSED | View |
REPAIR DOOR FRAME, MULLION | 2ND FLR.APARTMENT KITCHEN ENTRANCE DOOR FRAME TRANSOM PANE BROKEN,BATHROOM DOOR FRAME,MIDDLE BEDROOM DOOR FRAME AND APARTMENT DOOR FRAME;BROKEN. 3RD FLR.APARTMENT KITCHEN DOOR FRAME,APARTMENT DOOR FRAME;BROKEN | 2651 W DIVISION ST | PERIODIC | PASSED | View |
INSTALL DEAD BOLT LOCK | 3RD FLR.APARTMENT KITCHEN DOOR;NO LOCK | 2651 W DIVISION ST | PERIODIC | PASSED | View |
PROVIDE DEADLOCK FOR ENTRANCE | NORTH EXTERIOR DOOR LOCK;BROKEN [STICKS] | 2651 W DIVISION ST | PERIODIC | PASSED | View |
CARPETING | 3RD FLR.APARTMENT CARPET;UNSANITARY | 2651 W DIVISION ST | PERIODIC | PASSED | View |
POST OWNER/MANAGERS NAME/# | POST OWNERSHIP ON BUILDING | 2651 W DIVISION ST | PERIODIC | PASSED | View |
INSTALL SMOKE DETECTORS | INTERIOR STAIR,2ND AND 3RD FLR.APARTMENTS;NO SMOKE DETECTORS | 2651 W DIVISION ST | PERIODIC | PASSED | View |
CARB MONOX DETECT IN RESID | 2ND AND 3RD FLR.APARTMENTS;NO CARBON MONOXIDE | 2651 W DIVISION ST | PERIODIC | PASSED | View |
INSTALL COVERS | 2ND FLR.APARTMENT REAR BEDROOM WALL OUTLET,BATHROOM LIGHT SWITCH;NO COVER PLATES 1ST FLR.BATHROOM WALL OUTLET;NO COVER PLATE | 2651 W DIVISION ST | PERIODIC | PASSED | View |
EXPOSED WIRING | 1ST FLR.HALLWAY CEILING;EXPOSED WIRING 3RD FLR.FURNACE ROOM CEILING;EXPOSED WIRING | 2651 W DIVISION ST | PERIODIC | PASSED | View |
PERMIT REQUIRED | NO PERMIT FOR IRON GATE AND IRON FENCE | 2651 W DIVISION ST | PERIODIC | PASSED | View |
REPLACE DEFECTIVE TRAP | 2ND AND 3RD FLR.APARTMENTS KITCHEN SINK TRAPS;LEAKS | 2651 W DIVISION ST | PERIODIC | PASSED | View |
RESET LOOSE FIXTURE | 3RD FLR.APARTMENT BATHROOM TOLIET;LOOSE 1ST FLR.BATHROOM SINK;HANGING OFF THE WALL [NO SUPPORTS] | 2651 W DIVISION ST | PERIODIC | PASSED | View |
KEEP FIXTUR CLEAN AND SANITARY | 2ND FLR.APARTMENT BATHROOM TUB;PAINT CHIPS 3RD FLR.APARTMENT BATHROOM TUB;RUSTED | 2651 W DIVISION ST | PERIODIC | PASSED | View |
OBSTRUCTIONS IN EXIT WAY | REAR IRON FENCE;PADLOCK | 2651 W DIVISION ST | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | MISSING OWNERS I.D. SIGN | 2651 W DIVISION ST | PERIODIC | FAILED | View |
STRUCTURAL MEMBER, PIER BLOCK | BASEMENT WOOD COLUMNS ROTTED AT THE BASE [PERMITS FOR REPAIRS] | 2651 W DIVISION ST | PERIODIC | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | 3RD FLR.ENCLOSE PORCH WINDOW PANE;BROKEN | 2651 W DIVISION ST | PERIODIC | PASSED | View |
STOP LEAKING WATER | 2ND FLR.APARTMENT FURNACE ROOM CEILING,KITCHEN CEILING;AND BATHROOM CEILING;LEAKS | 2651 W DIVISION ST | PERIODIC | PASSED | View |