The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
POST OWNER/MANAGERS NAME/# | BUILDING OWNER'S ID SIGN - MISSING. | 1837 W ROSCOE ST | COMPLAINT | PASSED | View |
REPAIR EXTERIOR STAIR | FRONT EXTERIOR STAIRWAY - GRADE TO 1ST - COLUMNS AND BEAMS - ROTTED. LEDGER BEAM ONLY NAILED TO BUILDING. STRINGERS ONLY NAILED TO HEADER JOISTS AND COLUMNS. GUARDRAILS ONLY 32'' HIGH. GUARD AND HANDRAILS - BROKEN LOOSE FROM COLUMNS. | 1837 W ROSCOE ST | COMPLAINT | PASSED | View |
REPAIR EAVES | FRONT EAVES - ROTTED , BROKEN , AND MISSING SECTIONS WITH OPEN HOLES. REAR EAVES - SOUTHWEST FASCIA - METAL COVER SECTION - MISSING. | 1837 W ROSCOE ST | COMPLAINT | PASSED | View |
PROVIDE GUARD RAIL 42 IN HIGH | SOUTH BASEMENT STAIRWAY - GRADE TO BASEMENT - GUARDRAIL SECTION AND STAIR RAIL SECTION - MISSING. | 1837 W ROSCOE ST | COMPLAINT | PASSED | View |
SERVICE DROP OUT OF REACH | SOUTH AT 2ND - PORCH - ELECTRICAL SERVICE CONDUCTOR WITHIN REACH - GUARD - MISSING. | 1837 W ROSCOE ST | COMPLAINT | PASSED | View |
FLAM LIQ TANK FRONTAGE CONSENT | REAR UNDER PORCH STAIRS - STORING PROPANE GAS. REAR 2ND FLOOR PORCH DECK - STORING PROPANE GAS. | 1837 W ROSCOE ST | COMPLAINT | PASSED | View |
REPAIR PORCH SYSTEM | FRONT [ NORTH ] 3 STORY PORCH - NORTHWEST COLUMNS 2ND AND 3RD LEVELS - ROTTED , BOWED , SHIFTING , AND OUT OF PLUMB. PORCH BEAM AT 3RD - LOOSE , BROKEN , LOOSE , SAGGING , AND FALLING - DANGEROUS AND HAZARDOUS. LOOSE , BROKEN , AND ROTTED WOOD SECTIONS. GUARDRAILS ONLY 32'' HIGH - ROTTED AND WEAK. REAR , SOUTH , 3 STORY OPEN WOOD PORCH - 4 X 4 COLUMN ERECTED ON CONCRETE SLAB - FOUNDATION STATUS UNKNOWN. COLUMN SPLICES ONLY NAILED TOGETHER. COLUMNS STACKED . OVERNOTCHED COLUMNS - RIM BEAM AND RIM JOIST COLUMN NOTCHES IN CLOSE PROXIMITY OF EACH OTHER. LEDGER BEAMS ONLY NAILED TO BUILDING. 2 X 12 ANGLED BEAMS AT LANDINGS - ONLY NAILED. DECK JOISTS ONLY NAILED OR SCREWED TO LEDGER BEAMS , RIM BEAMS , HEADER JOISTS , AND RIM JOISTS. STRINGERS ONLY NAILED OR SCREWED TO COLUMNS AND HEADER JOISTS. TREADS - BROKEN , SPLIT AND ROTTED. DECKING - ROTTED. GUARDRAILS ONLY 39'' HIGH, LOOSE , ROTTED , WITH LOOSE , BOWED , AND BROKEN PICKETS. GUARDRAILS SPAN 6'4'' - MISSING MID SPAN COLUMNS. PLANS AND PERMIT REQUIRED FOR REPAIRS OF FRONT AND REAR PORCHES. | 1837 W ROSCOE ST | COMPLAINT | PASSED | View |
REPAIR/REBUILD GARAGE OR SHED | GARAGE - SIDING - LOOSE AND MISSING. EAVES - ROTTED. | 1837 W ROSCOE ST | COMPLAINT | PASSED | View |