Chicago Building Violations Data: 21 Violations
Violation Inspector Comments Address Category Status View
FLOOR, KIT & BATH NON-ABSORB APT 1 / KITCHEN FLOOR TILES - DAMAGED AND LOOSE. 8513 S SEELEY AVE COMPLAINT FAILED View
NO CLOSET/STORAGE UNDER STAIR REAR PORCH - STORING JUNK AND DEBRIS UNDER 1ST FLOOR DECK. 8513 S SEELEY AVE COMPLAINT FAILED View
UNAPPROVED HEATING DEVICE APT 1 - USING STOVE FOR HEAT AT TIME OF INSPECTION. CB046013 - UNAPPROVED HEATING DEVICE ( 14X-8-802.2) 8513 S SEELEY AVE COMPLAINT FAILED View
WORK NOT ALLOWED REMOVE ALL PARTITIONS AND FIXTURES INCLUDING PLUMBIN AND ELECTRIC INSTALLED IN THE BASEMENT WITHOUT A PERMIT. 8513 S SEELEY AVE COMPLAINT FAILED View
SERVICE WALK, PASSAGE, AREAWAY SOUTH ELEVATION / SERVICE WALK CRACKED AND COLLAPSING ( TRIPPING HAZARD ). 8513 S SEELEY AVE COMPLAINT FAILED View
REPAIR WINDOW SILLS NORTH AND SOUTH ELEVATIONS / SILLS - WASHED OUT MORTAR. 8513 S SEELEY AVE COMPLAINT FAILED View
WINDOW REPAIR FOR AIR SEEPAGE BUILDING / WINDOWS - BROKEN PANES. WINDOWS ARE DRAFTY WITH AIR SEEPAGE. ICE IS BUILT UP ON SOME WINDOWS AT TIME OF INSPECTION. 8513 S SEELEY AVE COMPLAINT FAILED View
SAFE WORKING CONDITIONS APT 1 / FURNACE DOOR - OPEN WITH EXPOSED WIRES. THERMOSTAT IS POORLY INSTALLED WITH LOOSE AND HANGING WIRES. CB132046 - SAFE WORKING CONDITIONS (14X-3-305.1, 14X-8-804.1 THRU 14X-8-804.4 AND 14X-8-804.5) 8513 S SEELEY AVE COMPLAINT FAILED View
INSTALL SMOKE DETECTORS APTS. 1, 2 FRONT STAIRWAY AND BASEMENT / SMOKE DETECTOR - MISSING. CB197019 - SMOKE ALARMS - INSTALL(14X-5-504.8, 14X-5-504.8.4,14B-9-907.210.1 THRU 14B-9-907.210.7,14B-9-915.4.4 AND 14R-11-1104) 8513 S SEELEY AVE COMPLAINT FAILED View
WINDOW REPAIR FOR AIR SEEPAGE BUILDING WINDOWS - OLD AND DRAFTY WITH AIR SEEPAGE. 8513 S SEELEY AVE COMPLAINT FAILED View
CARB MONOX DETECT IN RESID BASEMENT AND APT 1 / CARBON MONOXIDE DETECTORS - MISSING. CB197087- CARBON MONOXIDE ALARMS IN DWELLING ( 14X-5-504.9, 14B-9-915.1.1, 14B-9-915.2 AND 14RE -11-110 )CB197089 - CARBON MONOXIDE ALARM IN FUEL-BURNING ROOMS (14X-5-504.9, 14X-5-504.9.3, AND 14B-9-915. 8513 S SEELEY AVE COMPLAINT FAILED View
HEAT UNIT ADEQUATELY APT 1 / LIVING ROOM TEMPERATURE 54F AT 9:40 AM, BEDROOM 67F AT 9:40 AM. HEATING SYTEM IS ON, HEAT IS INSUFFICIENT. CB 132016 - HEAT DWELLING UNIT ADEQUATELY ( 14X-8-802.2, 14X -8-802.2.1, AND 14X-8-802.2.2) 8513 S SEELEY AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM EAST ELEVATION / 2 STORY PARTIALLY ENCLOSED PORCH / COLUMNS ROTTING AT BOTTOMS. COLUMNS ERECTEF ON CONCRETE BLOCKS AND DIRT. FOUNDATION STATUS - UNKNOWN. STRINGERS - ROTTING AND DETERIORATED. JOISTS - SHOWING SIGNS OF ROT AND ARE FASTENED WITH NAILS ONLY. 20X10 FOOT ADDED DECK AT 1ST FLOOR - 4X4 COLUMNS ERECTED ON DIRT FOUNDATION STATUS - UNKNOWN. GUARD RAILS SPAN UP TO 9 FEET LONG. ALL RAILING SYSTEMS - FASTENED WITH NAILS ONLY. INTERIOR OF 2ND FLOOR ENCLOSED PORCH WALLS - DAMAGED AND DETERIORATED WITH HOLES. PLANS AND PERMIT REQUIRED TO REPLACE ENTIRE PORCH STRUCTURE. SUBJECT TO FIELD INSPECTION AND APPROVAL. 8513 S SEELEY AVE COMPLAINT FAILED View
REPAIR INTERIOR WALLS/CEILING APT 1 / CEILINGS - WATER DAMAGED WITH BLACK SUBSTANCE OBSERVED. APT 2 HAS ACTIVE LEAK AT REAR. CEILING HAS COLLAPSED WITH EXPOSED WOOD LATH. 8513 S SEELEY AVE COMPLAINT FAILED View
REPAIR EAVES ROOF - LEAKING WATER. ROOF MATERIALS HAVE FALLEN ONTO REAR PORCH STAIRS. PERMIT REQUIRED TO REPLACE FLAT ROOF. 8513 S SEELEY AVE COMPLAINT FAILED View
PLANS & PERMITS REQ - CONTRCTR BASEMENT HAS BEEN CONVERTED INTO AN APT. 1ST AND 2ND FLOOR HAS HAD NEW FORCED AIR FURNACES INSTALLED WITHOUT PLANS OR PERMIT. SUBMIT PLANS AND OBTAIN PERMIT FOR ALL ALTERATIONS TO THE BUILDING OR RESTORE THE BUILDING TO THE ORIGINAL STATE. SUBJECT TO FIELD INSPECTION AND APPROVAL BY ALL RELATED TRADES. 8513 S SEELEY AVE COMPLAINT FAILED View
1HR FLR OVER BSMT, 1 OR 2 DU BASMENT CEILING - MISSING DRYWALL THROUGHOUT. 8513 S SEELEY AVE COMPLAINT FAILED View
REPAIR EXTERIOR DOOR FRONT ENTRY DOOR AND REAR 2ND FLOOR DOOR - DAMAGED BEYOND REPAIR. 8513 S SEELEY AVE COMPLAINT FAILED View
REPAIR EXTERIOR WALL NORTH AND SOUTH ELEVATIONS / EXTERIOR WALLS - SPALLED MASONRY WITH LOOSE BRICKS AND MORATR. 8513 S SEELEY AVE COMPLAINT FAILED View
PARAPET SOUTH ELEVATION / PARAPET - LOOSE AND MISSING BRICKS WITH WASHED OUT MORTAR. PERMIT REQUIRED FOR ALL MASONRY REPAIRS. 8513 S SEELEY AVE COMPLAINT FAILED View
SAFE WORKING CONDITIONS BASEMENT / ELECTRIC PANEL - OPEN WITH EXPOSED WIRES. 8513 S SEELEY AVE COMPLAINT FAILED View