Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-23 @ 7:52 PM
PIN: 11293060240000
Property Address: 1512 W FARGO AVE
City - Zip: CHICAGO - 60626
2023 Property Class: 597
2023 Township: 75 - Rogers Park
2023 Neighborhood: 75031
2023 Tax District: 75001
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 37 Violations
Violation Inspector Comments Address Category Status View
SUPPLY HOT WTR MIN TEMP 120DEG NO HOT WATER IN SOME UNITS 1512 W FARGO AVE COMPLAINT FAILED View
PRV CNTRL VALVE WATER SUPPLY REMOVE VALUE ON THE HOT OUTLET SIDE OF THE WATER HEATERS IN BASEMENT 1512 W FARGO AVE COMPLAINT FAILED View
OBTAIN PERMIT FOR HOTWATER HTR 2 WATER HEATERS IN BASEMENT 1512 W FARGO AVE COMPLAINT FAILED View
TEST ALTERED SYSTEM 1512 W FARGO AVE COMPLAINT FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA TEST F.A.I.DS AND ALL DEVICES RELATED TO SHUNT TRIP. 1512 W FARGO AVE PERMIT FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA MACHINE ROOM:1)PROVIDE MORE LIGHTING 2)PROVIDE REQUIRED DOOR HARDWARE 3)GFI RATED RECEPTACLE REQUIRED. 1512 W FARGO AVE PERMIT FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA PIT: 1)LADDER REQUIRED 2)SUMP COVER REQUIRED 3)MOVE LIGHT SWITCH TO LADDER SIDE 4)SINGLE GANG NON GFI RECEPTACLE REQUIRED FOR SUMP PUMP. 5)GFI RECEPTACLE REQUIRED. 1512 W FARGO AVE PERMIT FAILED View
OPEN TYPE VIOLATION REPAIR DOOR RESTRICTOR (A17.1A-1997 RULE) 1512 W FARGO AVE PERIODIC FAILED View
OPEN TYPE VIOLATION PROVIDE A-B-C RATED FIRE EXTINGUISHER IN ELEVATOR MACHINE ROOM. 1512 W FARGO AVE PERIODIC FAILED View
OPEN TYPE VIOLATION REPLACE DOOR GIBS WHERE MISSING AND BEND DOWN ALL FIRE TABS. 1512 W FARGO AVE PERIODIC FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA TEST F.A.I.DS 1512 W FARGO AVE PERMIT PASSED View
MAINTAIN OR REPAIR HYDRO ELEVA MACHINE ROOM: 1)PROVIDE REQUIRED DOOR HARDWARE. 1512 W FARGO AVE PERMIT PASSED View
MAINTAIN OR REPAIR HYDRO ELEVA PIT: 1)SINGLE GANG NON GFI RECEPTACLE REQUIRED FOR SUMP PUMP. 2)GFI RECEPTACLE REQUIRED. 1512 W FARGO AVE PERMIT PASSED View
PRV HIGH SIDE 450 PSIG FOR ONE 20 TON YORK CHILLER LOCATED ON ROOF. 1512 W FARGO AVE PERIODIC FAILED View
PRV PLUGGED/CAPPED 450 PSIG FOR ONE COPELAND 3/4 HP REMOTE REFRIGERATION UNIT LOCATED IN KITCHEN STORE ROOM. 1512 W FARGO AVE PERIODIC FAILED View
PRV HIGH SIDE 450 PSIG FOR ONE 20 TON YORK CHILLER LOCATED ON ROOF. 1512 W FARGO AVE PERIODIC PASSED View
PRV PLUGGED/CAPPED 450 PSIG FOR ONE COPELAND 3/4 HP REMOTE REFRIGERATION UNIT LOCATED IN KITCHEN STORE ROOM. 1512 W FARGO AVE PERIODIC PASSED View
MAINTAIN OR REPAIR HYDRO ELEVA CLEAN ELEVATOR PIT AND CARTOP. 1512 W FARGO AVE PERIODIC FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA SHOW PROOF OF COMPLIANCE WITH SECTION 8.6.5.8 OF A17.1-2007 (BULKHEAD REQUIREMENTS) 1512 W FARGO AVE PERIODIC FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA PERFORM CATEGORY 1 TEST. TAG AND DOCUMENT AS REQUIRED. 1512 W FARGO AVE PERIODIC FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA INSTALL WORKING 2 WAY COMMUNICATION (PHONE) IN ELEVATOR CAB. 1512 W FARGO AVE PERIODIC FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA INSTALL A CAPACITY TAG IN ELEVATOR CAB. 1512 W FARGO AVE PERIODIC FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA INSTALL "IN CASE OF FIRE" PICTOGRAPHS AT ALL LANDINGS. 1512 W FARGO AVE PERIODIC FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA GUARDS REQUIRED ON ALL LIGHTING-MACHINE ROOM,PIT,CARTOP,AND UNDER CAB. 1512 W FARGO AVE PERIODIC FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA IF SPRINKLERS ARE PRESENT IN MACHINE ROOM AND TOP OF HOISTWAY,HEAT DETECTORS AND SHUNT TRIPS MUST BE PROVIDED. 1512 W FARGO AVE PERIODIC FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA CLEAN ELEVATOR PIT AND CARTOP. 1512 W FARGO AVE PERIODIC FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA SCHEDULE INSPECTION OF ADDED SHUNT TRIP CIRCUIT WITH THE ELEVATOR BUREAU. CALL 312-743-3549 TO SCHEDULE. 1512 W FARGO AVE PERIODIC FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA GENERAL DUTY DISCONNECT SWITCH PROHIBITED.HEAVY DUTY DISCONNECT SWITCH REQUIRED. 1512 W FARGO AVE PERIODIC FAILED View
MAINTAIN OR REPAIR ELECT ELEVA INSTALL PROPER SUMP PUMP COVER AND PIT LADDER WITH LIGHT, AND GFI OUTLETS 1512 W FARGO AVE PERIODIC FAILED View
MAINTAIN OR REPAIR ELECT ELEVA INSTALL PROPER STOP SWITCH 1512 W FARGO AVE PERIODIC FAILED View
MAINTAIN OR REPAIR ELECT ELEVA PROPERLY ADJUST PASSENGER ELEVATOR CAR GATES 1512 W FARGO AVE PERIODIC FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA RELOCATE PIT LIGHT SO ELEVATOR DOES NOT STRIKE LIGHT. 1512 W FARGO AVE PERIODIC FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA REPAIR MALFUNCTIONING ALARM BELL. 1512 W FARGO AVE PERIODIC FAILED View
MAINTAIN OR REPAIR ELECT ELEVA INSTALL AN APPROVED PIT LADDER. 1512 W FARGO AVE PERIODIC FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA REPAIR MALFUNCTIONING DOOR RESTRICTOR. 1512 W FARGO AVE PERIODIC FAILED View
ENGAG LIC & BOND PLMBNG CNTRC 1512 W FARGO AVE COMPLAINT FAILED View
OPEN TYPE VIOLATION REPLACE DEFECTIVE PIT STOP SWITCH. 1512 W FARGO AVE PERIODIC FAILED View