Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-24 @ 3:54 AM
PIN: 13232150390000
Property Address: 3804 N SAWYER AVE
City - Zip: CHICAGO - 60618
2023 Property Class: 211
2023 Township: 71 - Jefferson
2023 Neighborhood: 71070
2023 Tax District: 71128
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 16 Violations
Violation Inspector Comments Address Category Status View
OPEN 3804 N SAWYER AVE PERMIT PASSED View
ROACHES UNITS 1 AND 2- SEVERE ROACH INFESTATION THROUGHOUT UNITS. 3804 N SAWYER AVE COMPLAINT FAILED View
INSTALL SMOKE DETECTORS NO SMOKE DETECTOR TOP OF FRONT STAIR AND TOP OF REAR ENCLOSED PORCH. 3804 N SAWYER AVE COMPLAINT FAILED View
OBSTRUCTIONS IN EXIT WAY REAR PORCH WITH OBSTRUCTIONS AT 1 AND 2- BIKES, COOLER, AIR CONDITIONING UNIT, BOXES. 3804 N SAWYER AVE COMPLAINT FAILED View
REPAIR/REBUILD GARAGE OR SHED GARAGE- ROTTING SIDING, FLAKING PAINT. LOOSE SIDING, HOLES. ROTTING ROOF DECKING AT EAVES. SECTIONS OF SOFFIT AND FASCIA MISSING, OTHER SECTION STILL INTACT BUT ROTTING. 3804 N SAWYER AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM ENCLOSED REAR PORCH- STAIRS FROM GROUND TO ONE LOOSE AND DEFLECTING. WEST STRINGER ROTTED, DETERIORATED AT GROUND. SEPARATING BEAM WEST SIDE AT 1RST. STRINGERS SIGNIFICANTLY PITCHED TOWARD WEST. 2X8 WINDER BEAM/ RISER BEFORE TO SINKING AT CONNECTION TO STRINGER, ANCHORED WITH TOE NAILS ONLY. CRACKED STRINGER AT 2- SPLIT. BEAM AND JOISTS SEPARATING AT 2, ANCHORED WITH NAILS ONLY. 2X4 USED AS OUTSIDE JOIST AT 2. CRACKED STRINGER HEADER AT 2. STRINGERS AT 1 ANCHORED TO FACE OF HEADER WITH TOE NAILS ONLY. SOUTH WEST COLUMN SIGNIFICANTLY ROTTED AT BASE. ALL COMPONENTS ANCHORED WITH NAILS ONLY. OBTAIN COMPLETE PLAN AND PERMIT. 3804 N SAWYER AVE COMPLAINT FAILED View
REPAIR EXTERIOR WALL EAST ELEVATION FRACTURES AT VARIOUS LOCATIONS, SPALLING BRICK, OPEN MORTAR JOINTS. 3804 N SAWYER AVE COMPLAINT FAILED View
PARAPET EAST ELEVATION PARAPET SOME FRACTURES, OPEN MORTAR JOINTS, SPALLING BRICK. 3804 N SAWYER AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION NO ENTRY BASEMENT. 3804 N SAWYER AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION INTERIOR OF THE BUILDING - NO RESPONSE, UNVERIFIED DETECTORS AND CONDITIONS. REAR YARD - LOCKED GATES, UNABLE TO INSPECT ENCLOSED REAR PORCH. 3804 N SAWYER AVE COMPLAINT FAILED View
CARPETING GRADE TO 2ND FLOOR / INTERIOR STAIRWAY'S CARPETING - SEVERELY SOILED AND RIPPED. 3804 N SAWYER AVE COMPLAINT FAILED View
REPAIR/REPLACE SMOKE DETECTORS GRADE TO 2ND FLOOR / INTERIOR STAIRWAY / TOP OF STAIRWAY / SMOKE DETECTOR - OUT OF SERVICE WITH MISSING BATTERY. 3804 N SAWYER AVE COMPLAINT FAILED View
REPAIR INTERIOR STAIR SYSTEM GRADE TO 2ND FLOOR / INTERIOR STAIRWAY / HANDRAILS - MISSING. 3804 N SAWYER AVE COMPLAINT FAILED View
PROVIDE DEADLOCK FOR ENTRANCE FRONT EXTERIOR DOOR' S DEADLOCK - MISSING. 3804 N SAWYER AVE COMPLAINT FAILED View
STOP LEAKING WATER UNIT 1 KITCHEN SINK LEAKING BELOW. 3804 N SAWYER AVE COMPLAINT FAILED View
REPAIR/REPLACE SMOKE DETECTORS SMOKE DETECTOR NOT OPERATING UNIT 2. 3804 N SAWYER AVE COMPLAINT FAILED View