Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR EXTERIOR WALL | SOUTH ELEVATION OF BUILDING-STEP FRACTURES BUILDING IS LEANING AT SOUTH | 1500 N ROCKWELL ST | COMPLAINT | FAILED | View |
SUBMIT 2 COPY STRUCTURAL RPT | BUILDING IS LEANING TOWARD THE SOUTH STRESS FRACTURES VISIBLE PROVIDE A STRUCTED ENGINEERS REPORT ON BUILDING STABILITY | 1500 N ROCKWELL ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR OPEN PORCH DOESN'T MEET CITY CODE IMPROPER GUARDRAIL SYSTEMS MISSING BOLTS ANGLE IRON STRAPS AND HANGERS WHERE NEEDED REPAIRS AND UPGRADES ARE TO REFLECT APPROVED DRAWING OR A STRUCTURAL ENGINEERS REPORT TO ALTER PORCH SYSTEM TO MEET 2006 CITY CODE ALSO TO INCLUDE PERMIT | 1500 N ROCKWELL ST | COMPLAINT | FAILED | View |
DWELLING CLEAN AND SANITARY | INTERIOR STAIRWAY AT 1500 FILTHY CONDITION | 1500 N ROCKWELL ST | COMPLAINT | FAILED | View |
CARPETING | INTERIOR STAIRWAY AT 1500 AND 1ST FLOOR UNIT AT 1500 CARPET LOOSE AND TORN MOLDY | 1500 N ROCKWELL ST | COMPLAINT | FAILED | View |
INT WALL/CEILING PEELING PAINT | WALLS AND CEILING 1500 POST FLOOR UNIT MOLDY | 1500 N ROCKWELL ST | COMPLAINT | FAILED | View |
UNSANITARY CONDITIONS-ANIMALS | REAR YARD UNDER PORCH DOG FOULING | 1500 N ROCKWELL ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | SCHEDULE COMPLETE INTERIOR INSPECTION WITH OWNER OR MANAGEMENT TO VERIFY DETECTORS IN ALL AREAS NEEDED TO COMPLETE INSPECTION OF PROPERTY | 1500 N ROCKWELL ST | COMPLAINT | FAILED | View |
STOP LEAKING WATER | 1500 1ST FLOOR UNIT BATHROOM AND FRONT OF UNIT WATER LEAKING | 1500 N ROCKWELL ST | COMPLAINT | FAILED | View |
NO POSTED ADDRESS | POST ADDRESS TO BE VISIBLE AT BUILDING ENTRANCES | 1500 N ROCKWELL ST | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | INTERIOR STAIRWAY 1500 AT 3RD NO SMOKE ALARM | 1500 N ROCKWELL ST | COMPLAINT | FAILED | View |
UNSANITARY CONDITIONS-ANIMALS | NORTH/REAR YARD:DOG FOULINGS. BL00831 | 1500 N ROCKWELL ST | COMPLAINT | FAILED | View |
USE SANITARY REFUSE CONTAINERS | BLDG. PREMISES: ACCUMULATION OF REFUSE AND GARBAGES. BL00831 | 1500 N ROCKWELL ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH SYSTEM: NO FOUNDATION FOOTINGS, COLUMNS SITTING ON CONCRETE WALKWAYS GRADE TO 1ST FLOOR TOP RAILS BROKEN AND MISSING SECTIONS DIAGONAL RAILING WITH EXCESSIVE GAP FOR PICKETS. GUARD RAILS BELOW 42' HIGH AND MISSING PICKETS. 2X8 FLOOR JOISTS SPAN 18' LONG. NO BOLTS ON LEDGERS AND STRINGER TO COLUMN CONNECTIONS LOOK OUT BEAMS ANCHORED TO COLUMN WITH LIGHT METAL STRIPS. 4X4 STACKED COLUMNS USED TO SUPPORT STAIR FLIGHT FROM L TO 2 AND RESTING ON 1ST FLOOR DECK BOARDS-NO FOUNDATION. FULL PLANS AND PERMIT REQUIRED FOR REPAIR OR REPLACEMENT. PLAN PROTO TYPE MAY BE AVAILABLE ONLINE | 1500 N ROCKWELL ST | COMPLAINT | FAILED | View |
FILE BLDG REGISTRATION | SR#801118186/BLDG. NOT REGISTERED FOR 2008. BL00831 | 1500 N ROCKWELL ST | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | INTERIOR ALTERATIONS OF BASEMENT OF 3 STORY MASONRY BUILDING INCLUDING BUT NOT LIMITED TO:REMOVED AND REPLACED LOAD BEARING BEAMS AND COLUMNS | 1500 N ROCKWELL ST | COMPLAINT | FAILED | View |
CONTRARY TO PLANS/OUT OF SCOPE | REMOVED AND REPLACED BASEMENT LOAD BEARING BEAMS ND COLUMNS | 1500 N ROCKWELL ST | COMPLAINT | FAILED | View |
BLANK-TEXT MUST CITE CODE SECT | STOP ALL WORK ON PREMISES UNTIL PLANS ARE APPROVED AND PERMIT IS OBTAINEDSECTION 12-080, 13-32-035. | 1500 N ROCKWELL ST | COMPLAINT | FAILED | View |
OPEN | 1500 N ROCKWELL ST | PERMIT | PASSED | View | |
SUBMIT 2 COPY STRUCTURAL RPT | PROVIDE ENGINEER REPORT FOR BUILDING LEANING TO SOUTH, MASONRY OPENING/FRACTURES. | 1500 N ROCKWELL ST | COMPLAINT | FAILED | View |
PERFRM STRUCT ENGINEER REPAIRS | PERFORM STRUCTURAL REPAIRS TO BUILDING ACCORDING TO ENGINEERS REPORT IN ORDER TO STABILIZE STRUCTURE | 1500 N ROCKWELL ST | COMPLAINT | FAILED | View |
STOP SMOKE, NOXIOUS ODORS | REAR YARD AND 1500 INTERIOR STAIRWAY NOXIOUS ODORS | 1500 N ROCKWELL ST | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | FRONT AND REAR NORTH AREAS LITTERED WITH DEBRIS | 1500 N ROCKWELL ST | COMPLAINT | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | 1500 1ST FLOOR UNIT THRU-OUT WALLS AND CEILING MOLDY SAGGING AND WATER DAMAGED | 1500 N ROCKWELL ST | COMPLAINT | FAILED | View |